Remodeling (462 SF) bedrooms and bathroom of existing home. Includes Mechanical, plumbing and electrical improvements.

542 S EL DORADO, Mesa
Nov 4

CONSTRUCT A 363-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS

11236 E PAMPA AVE, Mesa
Nov 3

New premanufactured Fiber Splice Enclosure on new foundation at facility under construction (PMT-24-15709). New mechanical and electrical. Special inspection for concrete construction. Group U Occupancy. Type II-B Construction. 115 SF. Approved as noted. Deferred Submittal for Fiber Splice Enclosure Walk-In Cabinet. Results in CoC.

10437 E ELLIOT RD, Mesa
Nov 3

Install one LED illuminated pan channel letter sets and logo flush mounted to front fascia of suite GREAT CLIPS 21 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.

550 W BASELINE RD 105, Mesa
Nov 3

PLUMBING PERMIT TO REPLACE SHOWER LIKE-FOR-LIKE. REPLACING PAN, DRAIN, AND VALVES. NO STRUCTURAL CHANGES. NEW INSTALLATIONS WILL TIE INTO EXISITING PIPING. NO CHANGE TO OVERALL SQUARE FOOTAGE. NO OTHER WORK UNDER THIS PERMIT. ALL WORK TO COMPLY WITH 2024 IRC AND 2023 NEC.

8049 E IRAN AVE, Mesa
Nov 3

Remove and install (1) LED PC logo ALLIED FORCES TEMPORARY SERVICES 16 sf.

420 E SOUTHERN AVE 108, Mesa
Nov 3

Addition of 1/2" gas line to new fireplace teeing off from existing gas pipe. Minimum required building inspections: Gas rough in and gas pipe final.

5029 S CAMBIUM LN, Mesa
Nov 3

Repair existing stem wall including installation of Glass Fiber Reinforced Polymer GFRP reinforcing bars and helical piles for foundation stabilization. Special inspections required for helical piles and GFRP reinforcing installation. Minimum required building inspections: Footing, stem, and final.

3513 N KASHMIR, Mesa
Nov 3

Suite 111 - Group S-1 occupancy. Type V-B construction. 9,626 SF. Occupant load 19 Suite 113 - Group S-1 occupancy. Type V-B construction. 9,626 SF. Occupant load 19 Existing warehouse suite split into two warehouse suites. Install demising wall and partition walls. New architectural and MEP. Results in CofO.

2836 N GREENFIELD RD 111, Mesa
Nov 3

Repair existing foundation including installation of Glass Fiber Reinforced Polymer GFRP reinforcing bars and helical piles for foundation stabilization. Special inspections required for helical piles and GFRP reinforcing installation. Minimum required building inspections: Footing, stem, and final.

452 W MENDOZA CIR, Mesa
Nov 3

Phase II Mechanical, Plumbing and Electrical improvements. High-piled combustible storage to be submitted under separate submittal. No modifications to fire protection systems. Reviewed with stipulations. Results in CoC.

7337 S 80TH ST, Mesa
Nov 3

Construct new 400 SF livable detached air-conditioned playhouse with storage loft and 294 SF non-livable area, including covered porch. Type V-B construction. Install new 100 amp electrical subpanel. No utility upgrades. Minimum required building inspections: Plumbing underground if applicable, footing, stem, pad elevation (conditional hold), strap/shear, frame, mechanical rough in, electric rough in, insulation, drywall shear, mechanical final, electric final and final.

1914 N ACACIA, Mesa
Nov 3

UNAUTHORIZED CONSTRUCTION. A detached 500 SF metal garage with electrical improvements. Swimming pool demo permit under PMT26-19097. Minimum required building inspections: Footing, stem, strap and shear, framing and final. If needed, underground electrical and plumbing. Ref. COD26-05738

1423 N ROWEN, Mesa
Nov 3

Plumbing permit to change out shower, like for like. Replace pan, drain, valves and using a glass door in the master bathroom. Glazing in shower doors shall be safety glazing – tempered. R324.4.1. Safety glazing required for tub or shower glazing less than 60” above standing surface. R324.4.5. No structural changes. New installations will tie into existing piping. Square footage will change from 3.42-ft x 4.92-ft. to 3.5-ft x 5-ft. No other work under this permit. All work to comply with 2024 IR

9308 E GREENWAY ST, Mesa
Nov 3

PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

4605 S ELEMENT, Mesa
Nov 3

Occupancy verification of an existing 2,806 SF, type VB construction, B and S1 occupancy suite. No construction work under this permit. No change in utilities or the exterior. Results in New CoO.

2942 N GREENFIELD RD 135, Mesa
Nov 3

Remodel existing suite, 8 new office constructed in existing office open area, new break room, AC existing warehouse. High-piled combustible storage by separate permit. Deferred fire sprinklers.

1907 S HOBSON 101, Mesa
Nov 3

Stem Wall Repair. Special inspections required for Stem wall repair.

11339 E COVINA ST, Mesa
Nov 3

Remove approximately 120 square feet of existing sidewalk within the City of Mesa right-of-way and construct a new 10 ft wide concrete driveway approach providing vehicular access from the street to the existing gravel driveway and gate. Work includes sawcutting, demolition, excavation, grading, subgrade compaction, forming, concrete placement, control joints, broom finish, and smooth transitions to the existing sidewalk and roadway. The pedestrian route across the driveway approach will be main

1548 N ROWEN, Mesa
Nov 3

PLUMBING PERMIT TO REPLACE EXISTING WET SPACE WITH NEW SHOWER IN MASTER BATHROOM. NEW VALVE AND PREFABRICATED ACRYLIC WALLS. NO STRUCTURAL CHANGES. NEW INSTALLATIONS WILL TIE INTO EXISITING PIPING. NO CHANGE TO OVERALL SQUARE FOOTAGE. NO OTHER WORK UNDER THIS PERMIT. ALL WORK TO COMPLY WITH 2024 IRC AND 2023 NEC.

222 W BROWN RD 31, Mesa
Nov 3

PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF

2113 W DEL CAMPO CIR, Mesa
Nov 3

PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

2241 E DOLPHIN AVE, Mesa
Nov 3

New 967 SF detached accessory structure with a new 27 SF entry porch with Mechanical, Plumbing and Electrical improvements. Minimum required building inspections: Plumbing underground, footing, stem, strap/shear, frame, mechanical rough in, electric rough in, plumbing rough in, insulation, drywall shear, mechanical final, electric final, plumbing final and final.

1118 N BARKLEY, Mesa
Nov 3

Addition

4605 E ELMWOOD CIR, Mesa
Nov 3

Convert 307 sq ft of existing patio to livable space, including electrical and 12k BTU mini split to existing SFR. VB construction. Minimum required building inspections: Footing, stem, strap/shear, frame, mechanical rough in, electric rough in, insulation, drywall shear, mechanical final, electric final and final.

1053 E 2ND PL, Mesa
Nov 3

New 360 Sq Ft non-livable accessory structure/golf simulator including new mini-split and electrical. Type V-B construction. Minimum required inspections: Footing, stem, strap/shear, frame, electrical rough in, mechanical rough in, insulation, drywall shear, electrical final, mechanical final and final. If needed, underground electrical.

2306 N ACACIA, Mesa
Nov 3

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE

5316 S PARKWOOD, Mesa
Nov 3

The scope of work is to remove the existing 3,000 gallon liquid nitrogen tank and replace it with a 6,000 gallon liquid nitrogen tank.

9019 E TECHNOLOGY AVE, Mesa
Nov 3

renovation of existing vacant suite into a new coffee shop

1840 W SOUTHERN AVE, Mesa
Nov 3

Install new 200 amp overhead service to replace existing 200 amp overhead service, like for like, per SRP design, at Clubhouse location. No additional load added. Old pole is rottiing out.

2528 E MCKELLIPS RD, Mesa
Nov 3