Search Permits
179,898 results
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 2200 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: AROUND THE HOUSE.
SELF CERT 2019 CBC: NEW CONSTRUCTION OF A MIXED USE FOUR STORY IIIA MASONRY BUILDING WITH GROUNDFLOOR COMMERCIAL & FIVE RESIDENTIAL APARTMENTS ABOVE AS PER PLANS (OCCUPANCY B, R2; CONSTRUCTIONTYPE IIIA)
FOR PERMIT B200466023: REPLACEMENT ELECTRICAL CONTRACTOR. REPLACEMENT GENERAL CONTRACTOR. REPLACEMENT PLUMBING CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
SCOPE: ROOF REPLACEMENT. AREA: 2500 SQ. FT. ROOF COVERING: MINERAL - SURFACED ROLL ROOFING. LOCATION: ROOF AREA. IL ROOFING CONTRACTOR LICENSE: 104020701.
CONCRETE MASONRY REPAIR / REPLACEMNT: 20SQ. FT., EXCAVATION = . LOCATION: SOUTH ELEVATION.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 2 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. 11.5 KWH LITHIUM ION ENERGY STORAGE SYSTEM. SPECIFIC LOCATION: SOUTHSIDE OF HOME.
PURPOSE: NEW/REPLACEMENT INSTALLATION. WOOD FENCE - 6'-0' ' (HEIGHT) X 70'-0' ' (LENGTH). LOCATION: REAR AND SIDE YARD.
HOIST CABLE REPLACEMENMT ON ONE(1) 4000LB CAPACITY, 61-FLOOR, 1200FPM, PASSENGER ELEVATOR(#2), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100821363)
MODERNIZATION OF THREE(3) 2500LB CAPACITY, 23-FLOOR, 600FPM, PASSENGER ELEVATORS(#1-#3), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV004209)
REPAIR/REPLACEMENT AFFECTING 2 SYSTEMS : 1 SPLIT SYSTEM(AMERICAN STANDARD, 5A6H7024, ROOF) 1 DUCT FURNACE(AMERICAN STANDARD, S9VB080, BASEMENT) 1 SPLIT SYSTEM(AMERICAN STANDARD, 5A6H7048, ROOF) 1 DUCT FURNACE(AMERICAN STANDARD, S9V2D120, BASEMENT) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), BASEMENT AND ROOF.
FOR PERMIT 101080762: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
CONCRETE MASONRY REPAIR / REPLACEMNT: 4564SQ. FT., EXCAVATION = NO. LOCATION: PARKING GARAGE.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 500 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: SMALL PARTIAL AREA OF TUCKPOINTING AT NORTH WALL.
REINSTATE PERMIT NO 100943258 MUST BEGIN WORK AND OR REQUEST INSPECTION NO LATER THAN ***SEPTEMBER 2026*** ON PERMIT NO 100943258
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: BASEMENT/REAR OF RESIDENCE.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 40 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT & REAR EXTERIOR WALL.
FOR PERMIT B200026168: REPLACEMENT GENERAL CONTRACTOR. REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
TEMPORARY SCAFFOLDING: QTY: 1, MAX. LENGTH: 27 FT., MAX. HEIGHT: 180 FT. LOCATION: NORTH ELEVATION. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE
IN-KIND REPLACEMENT OF EXTERIOR WINDOWS AND DOORS IN EXISTING OPENINGS. REPLACEMENT WINDOWS: 10; REPLACEMENT SKYLIGHTS: 0; REPLACEMENT DOORS: 2. AFFECTS: 2 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), LOCATION: EXISTING ELEVATIONS.
PURPOSE: LEGALIZE UNPERMITTED WORK. CHAIN LINK FENCE - 6'-0' ' (HEIGHT) X 48'-0' ' (LENGTH). LOCATION: VACANT LOT FENCING.
SPR 2019 CBRC: EXTERIOR IMPROVEMENTS FOR EXISTING WARREN PARK TO INCLUDE PARTIAL PAVEMENT REPLACEMENT, FOUR (4) PICKLEBALL COURTS, TWO (2) VOLEYBALL COURTS, BATTING CAGE, PLAY COURTS FOR BOCCE & SHUFFLEBOARD, WOOD DECK, NATURE PLAYGROUND, BENCHES, DRINKING FOUNTAIN. NO CHANGE IN ZONING DISTRICT AND USE.
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: 5TH FLOOR.
SPR 2019 CBRC: CONSTRUCTION OF NEW SECOND FLOOR REAR ADDITION AND TERRACE AND ALTERATION TO THE EXISTING 2-STORY WITH BASEMENT SINGLE FAMILY RESIDENCE WITH NEW FIRST FLOOR DECK. WORK TO INCLUDED ELECTRICAL, PLUMBING, AND HVAC (OCCUPANCY GROUP R-5; TYPE IIIB CONSTRUCTION)**CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS**
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 7500 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. PARAPET REBUILDING: 236 SQ. FT. LOCATION: NORTH ELEVATION.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: ASSEMBLY. START DATE: 7/18/2026. END DATE: 8/17/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 9.02 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 28 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: ELECTRICAL.
SCOPE: NONSTRUCTURAL INTERIOR ALTERATION TO LOBBY WITHIN EXISTING RESTAURANT, ADD NEW PARTITION, RELOCATE COUNTER AND ADD NEW ELECTRICAL. LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), LOBBY OF STOREFRONT.
REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS : 2 ROOFTOP PACKAGED UNIT(DAIKIN M# CARRIER M# 48VG-K240603-GP) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK, ROOF TOP.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 400 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: FRONT FAÇADE.