SCOPE: ROOF REPLACEMENT. AREA: 2192 SQ. FT. ROOF COVERING: ASPHALT SHINGLES. LOCATION: HOUSE AND GARAGE ROOF. IL ROOFING CONTRACTOR LICENSE: 104018992.

2406 S SPRINGFIELD AVE, Chicago
Oct 13

ADA MODIFICATIONS: REPLACE THE EXISTING WOODEN DECK, STAIRS AND HANDRAILS AT THE FRONT OF THE HOUSE.

6818 S TRIPP AVE, Chicago
Oct 13

ADA MODIFICATIONS: WIDEN EXTERIOR DOORWAY AT THE FRONT OF THE HOUSE.

2342 N MARMORA AVE, Chicago
Oct 13

2019 SPR: (1) NEW BASEMENT UNIT THROUGH ADU PROGRAM FOR AN EXISTING 3 STORY BRICK & FRAME BUILDING W/ M.E.P. WORK FOR NEW 0UNIT ONLY (AS PER PLANS), CONVERT FROM 3 DU TO 4 DU PER PLANS **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS

937 N HOYNE AVE, Chicago
Oct 13

WRECK AND REMOVE DETACHED FRAME GARAGE, NO REPLACEMENT. LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), GARAGE REMOVAL.

1519 W SCHOOL ST, Chicago
Oct 13

REPAIR OR IN-KIND REPLACEMENT OF 0 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), BASEMENT.

4138 N CLARENDON AVE, Chicago
Oct 13

SCOPE: ROOF REPLACEMENT. AREA: 5000 SQ. FT.ROOF COVERING: OTHER.LOCATION: ROOFS.IL ROOFING CONTRACTOR LICENSE: 104017759.

3650 W ARMITAGE AVE, Chicago
Oct 13

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 125 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: MAIN PANEL.

1645 N KILDARE AVE, Chicago
Oct 13

SELF-CERT 2019 CBC: NEW TWO STORY + BASEMENT SINGLE FAMILY HOME WITH 2 CAR ATTACHED GARAGE, WOOD DECK, 6FT WOOD FENCE (OCCUPANCY GROUP R-5; TYPE VA CONSTRUCTION)

3110 W WALLEN AVE, Chicago
Oct 13

SPR 2019 CBC BASEMENT CONVERSION AND DUPLEXING WITH 1ST FLOOR UNIT IN AN EXISTING 2 STORY, 2 DWELLING UNITS RESIDENCE WITH BASEMENT.

6015 W MONTROSE AVE, Chicago
Oct 13

INTERNALLY ILLUMINATED FACE-LIT BUSINESS ID SIGN TO STATE "ENDEAVOR HEALTH" WITH LOGO. 30'L X 4'-2"H

1460 N HALSTED ST, Chicago
Oct 13

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 4.95 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.

9226 S WOODLAWN AVE, Chicago
Oct 13

FOR PERMIT 101069227: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.

218 W KINZIE ST, Chicago
Oct 13

LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: EARL SHAPIRO.

5800 S STONY ISLAND AVE, Chicago
Oct 13

PERMIT EXPIRES ON 12/13/2026 ERECTION STARTS: 10/29/2026, ERECTION ENDS: 01/02/2027. SELF CERT CBC2019. REINSTATEMENT OF 2025 PERMIT 101075436 FOR THE 2026 CHRISTKINDLMARKET TENTS AT DALEY PLAZA FROM NOV 19 TO DEC 24, 2026. SET-UP OCT 29 AND TAKEDOWN BY JAN 2, 2027. SAME 1-20X45, 1-20X70 AND 1-20X115 TENTS. GERMAN AMERICAN EVENTS, LLC. WITH PARTYTIME-HDO OPERATIONS.

50 W WASHINGTON ST, Chicago
Oct 13

SELF-CERT; CBRC 2019: INTERIOR REMODEL OF FIRST FLOOR COMMERCIAL SPACE IN A ONE-STORY MASONRY BUILDING; NEW RESTAURANT; NEW KITCHEN HOOD; MODIFY HVAC, PLUMBING, AND ELECTRICAL SYSTEMS

2318 W DEVON AVE, Chicago
Oct 13

SC 2019 CBC: BUILDING PERMIT FOR NEW HOOKA LOUNGE IN EXISTING SINGLE-STORY BUILDING. NEW ELECTRICAL, PLUMBING, AND MECHANICAL DISTRIBUTION. OCCUPANCY GROUP A-2. CONSTRUCTION CLASSIFICATION III-A.

3877 N ELSTON AVE, Chicago
Oct 13

TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 200 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. PARAPET REBUILDING: 100 SQ. FT. LOCATION: FRONT FAÇADE.

1221 W WEBSTER AVE, Chicago
Oct 13

LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 45 . LIGHTING OUTLETS: 18. SPECIFIC LOCATION: BASEMENT, 1ST FLOOR, LOFT, AND EXTERIOR.

241 W 111TH PL, Chicago
Oct 13

NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.

4831 S LAPORTE AVE, Chicago
Oct 13

SCOPE: ROOF REPLACEMENT. AREA: 3259 SQ. FT. ROOF COVERING: BUILT-UP ROOF. LOCATION: ROOF AREA. IL ROOFING CONTRACTOR LICENSE: 104017799.

1625 W 18TH ST, Chicago
Oct 13

REINSTATE PERMIT#101046541 INSPECTION MUST BE SCHEDULED BY DECEMBER 2026

1828 N LINDER AVE, Chicago
Oct 13

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 30 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: BASEMENT.

6435 N LE MAI AVE, Chicago
Oct 13

TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 100 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: BUILDING EXTERIOR.

4101 S MICHIGAN AVE, Chicago
Oct 13

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 11.5 KW. ARRAY OUTPUT: 14.4 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.

10904 S EGGLESTON AVE, Chicago
Oct 13

PURPOSE: LEGALIZE UNPERMITTED WORK. WOOD FENCE - 6'-0' ' (HEIGHT) X 262'-0' ' (LENGTH). LOCATION: PROPERTY LINE FENCE.

3072 N AVERS AVE, Chicago
Oct 13

SELF CERT: ERECT 3 , WITH 13 R FULLY SPRINKLED, 4 UNIT APARTMENT BUILDING WITH BASEMENT AND 2 PRIVATE ROOF DECK, 2 ROOF ACCESS, COMMON NON-COMBUSTIBLE METAL EGRESS STAIR LOCATED BETWEEN DWELLING UNITS, SERVING AS THE SECOND MEANS OF EGRESS AND DETACHED 4 CAR GARAGE WITH ROOF DECK WITH PERGOLAS , FRONT ORNAMENTA IRON FENCES , EXISTING OCCUPANCY R-2 , PROPOSED OCCUPANCY R-2 , TYPE CONSTRUCTION VA , PER PLANS

4841 N KENMORE AVE, Chicago
Oct 13

FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101081350. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: SUITE 3700.

150 N MICHIGAN AVE, Chicago
Oct 13

PERMIT EXPIRES ON 12/13/2026 ERECTION STARTS: 10/28/2026, ERECTION ENDS: 11/2/2026. 2026 HOT CHOCOLATE 15K/5K CHICAGO - SMALL TENTSTENT- REINSTATE 101075054- SELF CERT- 1 DAY EVENT 11/1/2026ERECT ELEVEN (11) STRUCTURES- ONE (1) 10X70 FRAME TENT, ONE (1) 10X80 FRAME TENT, ONE (1) 20X30 FRAME TENT, ONE (1) 20X50 FRAME TENT, THREE (3) 30X50 (9MX15M) STRUCTURE TENT, TWO (2) 30X82 (9MX25M) STRUCTURE TENT, ONE (1) 40X82 (12M X 25M) STRUCTURE TENT, ONE (1) 50X50 (15MX15M) STRUCTURE TENT.ERECT 10/28/20

337 E RANDOLPH ST, Chicago
Oct 13

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 3.555 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.

9332 S BISHOP ST, Chicago