Minor Pool Remodel. Strip Plaster, Undercut Waterline Tile To Save, Apply New Plaster Material To Pool Interior.

21 N RIDGEWOOD RD, KENTFIELD, CA 94904, Marin County
Sep 29

Minor Pool Remodel. Strip Plaster, Undercut Waterline Tile To Save, Apply New Plaster Material To Pool Interior.

21 N RIDGEWOOD RD, KENTFIELD, CA 94904, Marin County
Sep 29

TI in an existing 47,051SF, construction type III-B building. Scope includes, accessory A occupancy break room, restrooms, and laser welder room. Crane structural permit under PMT26-06576 and Warehouse renovations under PMT26-08603. Deferred fire sprinklers. Special inspection for steel. Results in CoO.

7157 E SEAVER AVE, Mesa
Sep 29

Onsite grading, drainage, paving, utilities, landscaping, street lights, structural, and site electrical. Scope includes base of new monument sign for water feature and shade structure. Special inspection for steel, concrete, masonry, and soils. New (1) 2-inch landscape meter, (1) 3/4-inch water feature meter, (2) electric meters, and (1) gas meter. Deferred electric vehicle gate. Citrus trees to be installed within 6 months of CofO issuance. Results in CoC.

Unknown, Mesa
Sep 29

Installation of storage racks scope area of 191,364 SF in existing 353,600 SF, type VB construction, B and S-1 occupancy cold storage warehouse. Special inspection req for anchoring. REF: PMT24-10017 PH I and PMT24-11533 PH II. Results in CoC.

8959 E WARNER RD, Mesa
Sep 29

New subdivision offsite paving, utilities, signing and pavement marking. No new electric or water meters. Results in CoC.

Unknown, Mesa
Sep 29

Occupancy verification for an existing 2,475 SF, type VB construction, B occupancy suite. No change to building occupancy use -change from a Fitness/Nutrition business to Day Program for adults with developmental disabilities. Services include life skills training, socialization skills, creative arts, recreational activities, and community support. Building inspection req to verify existing condition. Approved with comments. Results in CoO.

2111 S ALMA SCHOOL RD 8, Mesa
Sep 29

GROUP HOME APPLICATION

11414 E SOLINA AVE, Mesa
Sep 29

CONSTRUCT A 341 SF SWIMMING POOL & 50 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 123-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 5-FT OF 3/4-IN PE GAS LINE TO 60K BTU BBQ. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL E

10141 E TIBURON AVE, Mesa
Sep 29

Repair damaged stem wall utilizing Glass Fiber Reinforced Polymer Rebar and Structural Repair Mortar. Special inspections required: Concrete construction. Approved as noted. Results in CofC.

719 N CHERRY, Mesa
Sep 29

New single-story custom home and ADU with 7938 SF livable and 2967 SF non-livable area. Livable area consists of 7073 SF main residence and 865 SF detached ADU. Non-livable area consists of a four car garage, covered patios and a covered entry. Type V-B construction. Existing 1 inch water meter. New 600 amp SES. New gas meter and new sewer connection. Deferred fire sprinkler calculations and truss calculations. Special inspections required for structural welding, high strength bolts, concrete co

3829 E HUBER ST, Mesa
Sep 29

Install above ground buildings and structures associated with Phase 02. Foundations and underground utilities for Phase 02 have previously been permitted under PMT24-07723. Other exclusions to this permit review include all pre-engineered metal buildings (PEMBs) located on the phase 02 site. These structures will be permitted through the Arizona Department of Housing (ADOH) and provided to the City of Mesa for fire code review as part of that submittal. Deferred fire sprinklers, fire alarms and

7232 E ELLIOT RD, Mesa
Sep 29

Residential Addition and Remodel – New 392 SF livable addition and 76 SF non livable addition - remodel 56 SF existing porch to livable space - remove walls at front entry and add new front entry area with roof trusses. Type V construction. R5 occupancy. Deferred truss calculations. Special inspections required for post epoxy anchors. No increase in utilities.

2553 E ADOBE ST, Mesa
Sep 29

Enclosing the exiting 180 SF rear covered patio to convert it into a playroom. No new square footage is being added. Minor mechanical and electrical improvements are included.

828 E FAIRFIELD ST, Mesa
Sep 29

Install one non-illuminated pan channel lettersets and logo flush mounted to front fascia of suite MUSIC LESSONS 80 sq. ft.

8017 E PECOS RD 105, Mesa
Sep 29

GAS SHUTOFF, PRECATION MEASURE DUE TO A FIRE

1940 W UNIVERSITY DR, Mesa
Sep 29

New 2166 SF single story residence with a 2+ car garage at Hawes Crossing. New water, gas and electric meters. Special inspection for post tension slabs **SEE ADDENDA MST25-07603**

8033 E RENATA AVE, Mesa
Sep 29

PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF

1009 W HICKORY ST, Mesa
Sep 29

Installation of 72-ft of 3.25-in PE gas line buried 18-in with 18-gauge tracer wire from gas meter to 55K BBQ, 22-ft of 3.25-in PE gas line from BBQ to 25K BTU firepit. All gas lines are to be installed per 2024 IFGC & COM gas requirements. Contact COM gas engineering at 480-644-2909 to determine if the meter needs to be upgraded. Reference addenda PMT26-00801A

435 E LEHI RD, Mesa
Sep 29

Install electrical substation to power Red Hawk Phase 2 Red building. Scope of work includes foundation, structural steel, electrical, and installation of prefabricated metal equipment enclosure. Ref: PMT24-16556 for Civil permit. Special Inspections are required for concrete, soils, steel, anchoring, and electrical installations. Results in CoC.

7232 E ELLIOT RD, Mesa
Sep 29

This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in plac

2120 W 8TH AVE, Mesa
Sep 29

SHEA HOMES #5016 - NEW 3505 SF TWO STORY RESIDENCE WITH A 3 CAR GARAGE AT AVALON CROSSING. INCLUES MANY ELEVATION OPTIONS. NEW WATER, ELECTRIC AND GAS METERS. Addenda per MST25-12445. Revised and added sheets for foundation slab depth for phase 2 foundations. SPECIAL INSPECTION FOR POST TENSION SLABS.

10442 E UNITY AVE, Mesa
Sep 29

New Ground up 19,406 gross SF (18,481 net SF) with 1,165 SF of canopy, ALDI retail store, with Civil. V-B construction with M, B, and S-2 occupancy. Walk-in freezers/coolers. Special inspection for structural items. Deferred fire sprinklers, fire alarm, joist and steel roof deck. New (1) 2-inch domestic water meter installed in previously placed meter box. REF: PMT23-18005 Master Developer. Approved with comments. Results in CoO.

6853 E ELLIOT RD, Mesa
Sep 29

Nomaco is looking to install an expanded foam process in an existing building they are leasing. Their process involves the usage of iso-butane to create an expanded foam material. This code study submittal is requesting a code interpretation of the NFPA 58 requirements for liquid LPGas inside of buildings and the provision and requirements needed.

10328 E MESQUITE ST, Mesa
Sep 29

Tenant improvement of existing type II-B construction, B occupancy suite. Modification include minor demolition and new demising wall partition to reduce suite SF to 3,334 SF. Existing ceiling grid and tile to remain throughout, minor lighting relocation to suit new layout. Minor mechanical and electrical modifications to suit new layout. Deferred fire alarm. Results in CoO.

1640 S STAPLEY DR 132, Mesa
Sep 29

Installation of one set of LED Illuminated front-lit pan channel letters and logo box flush-mounted to the wall, secured with anchors and bolts. LITTLE ARROWS CHILD CARE 31 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.

810 E SOUTHERN AVE, Mesa
Sep 29

Install (1) exterior wall mounted non illuminated RPC LITTLE & BIG SMILES DENTISTRY 30 sf.

8419 E BASELINE RD 101, Mesa
Sep 29

Install (1) illuminated double sided monument sign CIRCLE THE CITY 10.9 sq ft.

5456 E MAIN ST, Mesa
Sep 29

Group B and A-3 occupancies. Type III-B construction. 10,940 SF. Occupant load 177. Renovations to existing building. Demo identified exterior door/frame, iron rod fence/gate, furring/insulation at all exterior walls and new opening in exterior wall. Install new steel lintel, 1-hour rated partition walls at conference room, and masonry wall infill. New main entrance and side entrance gates. New folding partition wall in conference room. New mechanical heat pump RTUs, condensate drain lines, supp

650 W SOUTHERN AVE, Mesa
Sep 29

New Detached 1600 sq ft garage including 216 sq ft covered porch and new 125-amp electrical panel. VB Construction. Minimum required building inspections: Footing, stem, strap and shear, electric rough in and electric final, framing and final. If needed, underground electrical.

439 S 30TH ST, Mesa
Sep 29