PermitDig

Search Permits

167,869 results

PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

9713 E OLLA AVE, Mesa
Jul 8

New Sewer Service - 6419 E Avalon St - County Island

Unknown, Mesa
Jul 8

Construct a new 342 SF livable addition to an existing park model consisting of a living room - bathroom - and laundry room on a raised deck. Type V construction. R5 occupancy. No change to electrical service - water service - or gas service. No deferred items. No special inspections. Minimum of one 9-ft x 18-ft unobstructed paved parking space required behind front setback on 2-in asphalt or 4-in concrete. 39-ft x 50-ft interior lot. Minimum setbacks are 7-ft front, 5-ft interior rear lots, 5-f

111 S GREENFIELD RD 334, Mesa
Jul 8

Install residential driveway approach for RV gate access. Remove approximately 10 LF of curb and construct concrete driveway approach.

5428 E FARMDALE AVE, Mesa
Jul 8

CONSTRUCT A 333-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS

6245 E PEARL ST, Mesa
Jul 8

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE

1526 E IVYGLEN ST, Mesa
Jul 8

Remodel of 22 SF exiting shower. Replacing pan, drain, seat, wall finish, and valves.

8148 E PETRA AVE, Mesa
Jul 8

CIP - City Well 13 Equipping The scope of work is to equip an existing drilled well and demo the old well site. This will include Demo, Civil, Site Plan, Structural and Electrical work. The newly drilled well will be equipped with a shaft and all the associated equipment, electrical controls, chlorination house/controls, and structural structures to equip a well site. Special inspection req. - steel, masonry. Water Meters: (1) 1.5-inch and (1) 3ph Elect Meter. Deferred vehicle access gate and g

242 E 3RD AVE, Mesa
Jul 8

Widen the existing ingress/egress driveway at the Higley Road access point to a total width of 71 feet.

3228 N HIGLEY RD, Mesa
Jul 8

New Convenience Store, Fuel Canopy, Trash Enclosure (uncovered), and Underground Storage Tanks as associated with fuel sales. Civil/landscaping Plan review permit # PMT26-07500.

7223 S SOSSAMAN RD, Mesa
Jul 8

Converting shower to shower, replacing pan, drain, and valves at existing SFR. No change to overall square footage.

7057 E PLATA AVE, Mesa
Jul 8

Converting tub to shower at existing SFR. Replacing pan, drain, and valves. Using a glass door. No change to overall square footage.

637 S ROSEMONT, Mesa
Jul 8

Enclose entry porch to add powder room, move interior wall at garage to enlarge dining room, widen previously unpermitted patio cover to extend across back of house, add small attached storage shed and create enclosure for pool equipment. Additions result in 160 S.F. existing under roof remodeled into livable, and newly permitted 415 S.F. non-livable under new roof.

2461 S EXTENSION RD, Mesa
Jul 8

Tenant improvement of 27,693 SF Vault 1.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs

10256 E ELLIOT RD, Mesa
Jul 8

Hall bathroom tub-to-shower conversion with 60x30 low-profile Preformed shower base (left drain), no drain relocation, no structural changes.

1037 E 9TH ST, Mesa
Jul 8

Two new light poles in the existing parking lot. No new meters. Special inspection for concrete and foundations. Results in CoC.

5620 E ADOBE RD, Mesa
Jul 8

CONSTRUCT A 398 SQ FT RAISED DECK AND 120 SQ FT SHED UNDER EXISTING AWNING. SHED IS CONSTRUCTION PARTIALLY UNDER EXISITNG AWNING. ALL NEW CONSTRUCTION SHALL MEET CODE PER 2024 IRC AND 2023 NEC. REFERENCE PARK MODEL PERMIT PMT24-19081. MINIMUM ONE 9-FT X 18-FT UNOBSTRUCTED PAVED PARKING SPACE IS REQUIRED TO BE ON 2-IN ASPHALT OR 4-IN CONCRETE BEHIND THE FRONT SETBACK. INTERIOR 34.64-FT X 63.51-FT LOT. MIN SETBACKS: 4-FT FRONT, 5-FT REAR, 0-FT PM SIDE AND 3-FT CARPORT SIDE. NO OTHER ACCESSORY STR

5001 E MAIN ST 417, Mesa
Jul 8

Tenant improvement of 27,681 SF Vault 1.3 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs

10256 E ELLIOT RD, Mesa
Jul 8

Tenant improvement of 27,674 SF Vault 1.2 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs

10256 E ELLIOT RD, Mesa
Jul 8

Tenant improvement of 27,683 SF Vault 2.3 in an existing type II-B, S-1 occupancy space. Modification includes the expansion of the mechanical & electrical systems to support NTT client's equipment in the Vault space. Install of Generators, electrical modules in yard and chillers on existing rooftop equip platform. Special inspection req. - steel, concrete, soils. Special Inspections for Emergency Responder Radio Coverage. Deferred: Seismic bracing of equip and metal platform & grating, stairs

10256 E ELLIOT RD, Mesa
Jul 8

Install bulk carbon dioxide (CO2) monitoring system for beverage dispensers. Results in CoC.

6560 E SUPERSTITION SPRINGS BLVD, Mesa
Jul 8

Build new 387 sq ft addition with a 119 sq ft storage-laundry area at the back and a 166 sq ft open deck area at the front. Includes a new 200A service panel upgrade. Min (1) 9' x 18' unobstructed paved (2” asphalt or 4” concrete) parking space required behind front setback. 63.51' x 34.54' interior lot. min setbacks: 4' front, 5' rear, 0' park model side & 3' awning/carport side. approved as noted.

5001 E MAIN ST 226, Mesa
Jul 8

Community Residence registration: Assisted Living Home for 6-10 residents. Sprinkered (in the process of installation)

9804 E SPEED AVE, Mesa
Jul 8

CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 26.67-FT X 40-FT 2026 ABOVE GROUND CAVCO MH SET, SERIAL NO. CA110AZ2623187AB, WITH A/C AT REAR. NO GAS. ONE 18-FT X 18-FT ATTACHED AWNING PER ICC NO. 1390. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM OF TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK AND REQUIRED TO BE ON 2-IN ASPHALT OR 4-IN CONCRETE. ONE PARKING SPACE REQUIRED TO BE COVERED. ODD SHAPED INTERIOR CORNER LOT. MIN SETBACKS:

4065 E UNIVERSITY DR 83, Mesa
Jul 8

New 2667 SF two story residence with a 2 car garage in AVALON CROSSING. Includes electric, gas and water meter. Elevation E has second story balcony. Special inspection for post tension slabs

6316 S ARCHER CIR, Mesa
Jul 8

Construction of new 10,927 SF, type II-B, group M and S-1 occupancy Tire retail and garage shop. To include 735 SF canopy and 2,727 SF mezzanine. Water Meters: 1.5-inch domestic, and 3/4-inch landscape. Special inspection req. - fabricator, steel, concrete, masonry, soil, anchoring. Deferred fire sprinklers. Deferred fire alarm. Deferred high-piled combustible storage. Deferred Roof Steel Joist. Deferred Steel Stairs. Approved with Stipulations. Results in CoO. 3403 S Ellsworth Rd LD1 is the add

3501 S ELLSWORTH RD, Mesa
Jul 8

PAD B 3060 SF new building with proposed restaurant, retail, and outside areas. Group A-2, M, and B occupancies. Type V-B Construction. Special Inspections are required for Steel Construction, Concrete Construction, Masonry Construction, Fabricated Items, soils, and Post Installed Anchors. New electrical meters 100 AMP and 2-inch domestic water meter. Deferred submittal for Pre-Manufactured Wood Trusses. Fire sprinklers and fire alarm plans are included in this permit plan set. Results in CofC.

1223 S SIGNAL BUTTE RD, Mesa
Jul 8

Tenant improvement of existing 9626 SF, type VB construction, S-2 occupancy. Modification include new walls for new ADA restroom, associated structural, plumbing, electrical, and mechanical roof curb for future units - no mech ventilation. Special inspection req. - Steel. No high-piled storage or hazardous material. Deferred fire sprinklers. Changed occupancy information, new electrical meter, result of permit to CoO per PMT25-08784A. Results in CoO.

2836 N GREENFIELD RD, Mesa
Jul 8

Tenant improvement of existing 9626 SF, type VB construction, S-2 occupancy. Modification include new walls for new ADA restroom, associated structural, plumbing, electrical, and mechanical roof curb for future units - no mech ventilation. Special inspection req. - Steel. No high-piled storage or hazardous material. Deferred fire sprinklers. Changed occupancy information, new electrical meter, result of permit to CoO per PMT25-08785A. Results in CoO.

2836 N GREENFIELD RD, Mesa
Jul 8

Tenant improvement of existing 9626 SF, type VB construction, S-2 occupancy. Modification include new walls for new ADA restroom, associated structural, plumbing, electrical, and mechanical roof curb for future units - no mech ventilation. Special inspection req. - Steel No high-piled storage or hazardous material. Deferred fire sprinklers. Changed occupancy information, new electrical meter, result of permit to CoO per PMT25-08781A. Results in CoO.

2836 N GREENFIELD RD, Mesa
Jul 8