CONSTRUCT A NEW 188 SF LIVABLE ADDITION WITH ELECTRIC. PERMIT EXISTING UNPERMITTED 111 SF SHED WITH ELECTRIC AND PLUMBING. MINIMUM OF TWO 9-FT X 18-FT UNOBSTRUCTED PAVED, 2-IN ASPHALT OR 4-IN CONCRETE, PARKING SPACE REQUIRED BEHIND FRONT SETBACK WITH A MINIMUM OF ONE COVERED. 68-FT X 79-FT INTERIOR CORNER LOT. MINIMUM SETBACKS ARE 5-FT FRONT, 10-FT REAR, 5-FT SIDES. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. REF. HOST PERMIT 124069 FOR EXISTING MANUFACTURED HOME, GARAGE
SRP replacing existing utility transformers with new. Demo existing 600A SES. Install new 600A 3 phase SES and electrical meter. No changes to current loads on the 600A SES. Results in CofC.
Install two 2-inch backflow devices with enclosures on exist water services. Water meters existing.
Tub to Shower Conversion in Master Bathroom at existing SFR - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.
Remove and replace existing electrical equipment at existing cell tower site. Approved as noted. Results in CofC.
THE SCOPE OF THIS PROJECT IS A TENANT IMPROVEMENT TO AN EXISTING BUILDING. WORK TO NCLUDE BUILD OUT OF ONE NEW OFFICE SUITE AND VENTILATION PER CODE WITHIN WAREHOUSE, AND ALL ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL. NOTES: EXISTING SPEC SUITE PREVIOUSLY PERMITTED AND BUILT UNDER PERMIT PMT23-02565
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 16-FT X 56-FT 2026 GROUND SET CLAYTON MANUFACTURED HOME, SERIAL NO. BUC017865AZ WITH A/C AT REAR. GAS. ONE 11-FT X 40-FT AWNING PER ICCESR 1398. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES REQUIRED BEHIND THE FRONT SETBACK WITH ONE COVERED AND BOTH ON 2-IN ASPHALT OR 4-IN CONCRETE. 40-FT X 75-FT INTERIOR LOT. MINIMUM SETBACKS ARE1-FT FRONT, 4-FT REAR, 3-FT MH SIDE, 1-FT OPEN P
Potholing plan for underground utility excavation
No structural wall changes. Toilet bowl and plumbing stays in the same location. Bathtub location will be moved along with the plumbing. Vanity will be moved along with the plumbing. Window will be decreased to a smaller size. Electrical outlet will be moved to the vanity wall.
Replace existing 100 amp pedestal electrical panel, like-for-like in same existing location.
Remodel the existing Mexican food restaurant to Korean BBQ restaurant. Deferred fire sprinklers, hood AFES and fire alarm.
Build an attached ADU to an existing residence. No new meters or upgrades. The ADU has a kitchen, one bedroom, one bath and a living room. The existing laundry room has an exterior door for access.
R-4 OCCUPANCY GROUP CONDITION 2. Community Residence Registration Application and Certificate of Occupancy for residential care home operating as a licensed Family Community Residence - Assisted Living Home. Name: Four Hands Assisted Living Home LLC. Mesa Zoning Code 11-31-14 limits the number of residents to 10. No skilled nursing services allowed. 24-hour care. R-4 Occupancy Group Condition 2. MBC 310.5. This occupancy condition shall buildings, structures or portions thereof for more than fiv
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
Installation of 16'x56' Manufactured Home, Above Ground Vinyl Skirting, Connect to 200 AMP pedestal, water and sewer
This project is for 37 Roof mounted modules + Tesla Powerwall 3 whole home back up using the Tesla back up switch
Replace existing 100 amp pedestal electrical panel, like-for-like in same existing location.
Applying for a Certificate of Occupancy for our DCS Licensed Foster home.
Tenant improvement in existing 3,107 SF, type VB construction, B occupancy office suite with printing/production. Modifications include demo of non-load bearing walls, existing ceiling, new walls to create conference room, printing room, production room, several office spaces and a breakroom with associated electrical plumbing and mechanical. Existing bldg common area restroom. Deferred fire sprinkler, fire alarm and access control. Results in CoO.
Tenant improvement for existing 2,732 SF, type VB construction for group M retail store. Modifications include demon of interior walls, millwork, restrooms and ceilings, new (1) ADA restroom, walls to create front sales area and separate stockroom, new ceiling, lighting, ductwork from existing RTU, plumbing for new fixtures and water heater. Deferred fire sprinklers. Results in CoO.
CONSTRUCT A 399 SF SWIMMING POOL & 64 SF SPA NO ELECTRICAL HEAT. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA
Remove and replace existing electrical equipment at an existing wireless cell tower site. Results in CofC.
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 28-FT.10-IN X 37-FT.6-IN 2027 ABOVE GROUND CAVCO MANUFACTURED HOME SET SG-30381C WITH A/C ON NORTH SIDE. NO GAS/NO LP TANKS. ONE 15FT.6-IN X 21-FT ATTACHED AWNING PER ICC NO. ESR1398. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN ONE 9-FT X 18-FT PAVED 2-IN ASPHALT OR 4-IN CONCRETE UNOBSTRUCTED PARKING SPACE IS REQUIRED BEHIND FRONT SETBACK. 41-FT X 51-FT PERIMETER LOT. MIN SETBACKS: 7-FT FRONT, 5-FT REAR, 5-FT SIDES. APPROVED AS N
TI in an existing 47,051SF, construction type III-B building. Scope includes, accessory A occupancy break room, restrooms, and laser welder room. Crane structural permit under PMT26-06576 and Warehouse renovations under PMT26-08603. Deferred fire sprinklers. Special inspection for steel. Results in CoO.
Install (2) exterior wall mounted illuminated signs with pan channel lettering: FIFTH THIRD BANK w/logo 24.5 sq ft each.
Landsea Homes #35-2100 Master plan for new 2,725 S.F. single-family home construction. New water and electric meters. Special inspections required for post-installed anchors in PT slab and Special Inspection Certificate for Unconfirmed Energy Report Requirements. Truss Calcs deferred. Addenda MST24-21772 - modifications insulation blown in cellulose, vent calculating to reflect the correct number of vents, removed additional attic scuttle/access from garage, structural and mechanical revisions
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
Install manufactured home with utilities
Build new addition with a total area of 516 sq ft. 396 sq ft of living area and 120 sq ft of storage and laundry area.
New 144 units multi-family development comprising of 6, 3-stories buildings. Development includes detached single story leasing/clubhouse, maintenance building, mail ramada and BBQ ramada. R-2/ A-3 / B occupancies. Type VB and VA construction. Special inspection required for steel, concrete, masonry, wood, soils and anchoring. Water meters: (2) 2-inch domestic. Deferred fire sprinklers and fire alarms and gates. Civil under PMT24-03644. (Cover parking structures under separate permit.)