Install one non-illuminated pan channel lettersets and logo flush mounted to front fascia of suite MUSIC LESSONS 80 sq. ft.
GAS SHUTOFF, PRECATION MEASURE DUE TO A FIRE
New 2166 SF single story residence with a 2+ car garage at Hawes Crossing. New water, gas and electric meters. Special inspection for post tension slabs **SEE ADDENDA MST25-07603**
PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF
Installation of 72-ft of 3.25-in PE gas line buried 18-in with 18-gauge tracer wire from gas meter to 55K BBQ, 22-ft of 3.25-in PE gas line from BBQ to 25K BTU firepit. All gas lines are to be installed per 2024 IFGC & COM gas requirements. Contact COM gas engineering at 480-644-2909 to determine if the meter needs to be upgraded. Reference addenda PMT26-00801A
Install electrical substation to power Red Hawk Phase 2 Red building. Scope of work includes foundation, structural steel, electrical, and installation of prefabricated metal equipment enclosure. Ref: PMT24-16556 for Civil permit. Special Inspections are required for concrete, soils, steel, anchoring, and electrical installations. Results in CoC.
This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in plac
SHEA HOMES #5016 - NEW 3505 SF TWO STORY RESIDENCE WITH A 3 CAR GARAGE AT AVALON CROSSING. INCLUES MANY ELEVATION OPTIONS. NEW WATER, ELECTRIC AND GAS METERS. Addenda per MST25-12445. Revised and added sheets for foundation slab depth for phase 2 foundations. SPECIAL INSPECTION FOR POST TENSION SLABS.
New Ground up 19,406 gross SF (18,481 net SF) with 1,165 SF of canopy, ALDI retail store, with Civil. V-B construction with M, B, and S-2 occupancy. Walk-in freezers/coolers. Special inspection for structural items. Deferred fire sprinklers, fire alarm, joist and steel roof deck. New (1) 2-inch domestic water meter installed in previously placed meter box. REF: PMT23-18005 Master Developer. Approved with comments. Results in CoO.
mechanical_hvac
mechanical_hvac
electrical_service_/_circuit_/_feeder
electrical_service_/_circuit_/_feeder
residential_re-roofing
electrical_service_/_circuit_/_feeder
mechanical_hvac
residential_re-roofing
mechanical_hvac
change_of_address
mechanical_hvac
mechanical_hvac
change_of_address
mechanical_fuel_gas
mechanical_fuel_gas
mechanical_fuel_gas
mechanical_fuel_gas
mechanical_fuel_gas
renovation_(structural_or_non-structural)
mechanical_hvac
mechanical_fuel_gas