NONSTRUCTURAL PREPARATORY DEMOLITION OF NON-LOAD BEARING PARTITIONS AND M.E.P. SYSTEMS WITH DEMO DRAWINGS AND ALL OTHER WORK TO BE PERFORMED ON SPR APPLICATION/PERMIT #101088377. LOCATIONS: 2 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), BASEMENT, 1ST, 2ND, AND 3RD FLOORS.
DDS 2019 CBRC: INTERIOR AND EXTERIOR ALTERATIONS TO EXISTING 5 STORY 53 UNIT SENIOR LIVING APARTMENT BUILDING. WORK TO INCLUDE NEW APPLIANCES AND FIXTURES IN ALL UNITS; GROUND FLOOR TENANT AMENITY SPACE RENOVATION; WINDOW REPLACEMENT, MASONRY REPAIRS, NEW CLADDING AND NEW ELEVATOR AS PER PLANS. TYPE IIA CONSTRUCTION. R-2 RESIDENTIAL.CONSULTANT REVIEWER: V3 COMPANIES OF IL
DEMOLITION OF A 2-STORY RESIDENTIAL OCCUPANCY BUILDING. 2 RESIDENTIAL UNITS. 0 NON-RESIDENTIAL UNITS. INCLUDES DEMOLITION OF RESIDENTIAL PRIVATE GARAGE. LOCATION ON LOT: FRONT. (COMPLEX DEMOLITION.)
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 125 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: METER, EXTERIOR.
INSTALLATION OF ONE (1) SINGLE-SIDED, INTERNALLY ILLUMINATED SIGN CABINET ON WEST ELEVATION AND CONNECT TO SUPPLIED LEADS.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 9.45 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 11.5 KW. ARRAY OUTPUT: 2.7 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF DETACHED STRUCTURE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
LIMITED REPAIR (25% OR LESS) FOR WOOD PORCH (OPEN) (QUANTITY: 1, LOCATION: FRONT OF BUILDING). LANDING: 75 SQUARE FEET. LANDING NOT MORE THAN 6 FEET ABOVE GROUND.
FOR PERMIT 101081063: ADDITIONAL MASON CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
SPR 2019 CBRC. REVISION TO PERMIT # 101065762: RELOCATE FURNACE FROM BASEMENT TO 2ND FLOOR FOR 2ND FLOOR RESIDENTIAL DWELLING UNIT AND RELOCATE 1ST FLOOR HVAC DUCTS FROM 1ST FLOOR UNIT IN BASEMENT AT 4421 N ARTESIAN AVE. (CONSTRUCTION TYPE IIIA, USE GROUP R-5).
INSTALLATION OF INTERNALLY ILLUMINATED DOUBLE SIDED MONUMENT SIGN TO READ "HOYNE" ON THE EAST ELEVATION, CONNECTING TO ALREADY EXISTING CUSTOMER LEADS ONLY - SIGN 3
LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 100 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: GARAGE.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: EDUCATION. START DATE: 9/25/2026. END DATE: 9/25/2027. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
SCOPE: ROOF REPLACEMENT. AREA: 2000 SQ. FT. ROOF COVERING: BUILT-UP ROOF. LOCATION: REROOF 20SQ WITH ALL NECESSARY ACCESSORIES.. IL ROOFING CONTRACTOR LICENSE: 104020671.
LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 100 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: GARAGE.
SPR 2019 CBRC: INTERIOR RENOVATION OF AN EXISTING TWO STORY 2-UNIT MASONRY IIIA WITH A UNFINISHED BASEMENT RESIDENTIAL BUILDING ZONING RT-4 REMOVE AND RPLACE EXISTING REAR WOOD STAIR AND REMOVE ABD REPLACE EXISTING MASONRY GARAGE WITH NEW WOOD FRAME GARAGE AS PER PLANS**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **
SPR 2019: REMOVE AND REPLACE TWO (2) RTUS TO ROOF EXISTING ROOF SLAB TO 2-STORY MANUFACTURING BUILDING AS PER PLANS. (OCCUPANCY F: CONSTRUCTION: 3B)
SPR 2019 CBC:INTERIOR ALTERATIONS OF EXISTING 1ST FLOOR VACANT COMMERCIAL SPACES (TO CORRECT BUILDING CODE VIOLATIONS) IN EXISTING 3 STORY MIXED USE BUILDING AS PER PLAN. NO MECHANICAL WORK.
ERECT NEW VERTICAL BLADE SIGN ON SOUTH SIDE OF EXISTING BUILDING, TO READ "TRADER JOE'S"
CHANNEL LETTERS ON RACEWAY READING "POPEYES"
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: 4TH FLOOR.
IN-KIND REPLACEMENT OF EXTERIOR WINDOWS AND DOORS IN EXISTING OPENINGS. REPLACEMENT WINDOWS: 15; REPLACEMENT SKYLIGHTS: 0; REPLACEMENT DOORS: 2. AFFECTS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 2 INTERIOR COMMON AREAS, LOCATION: FELLOWSHIP HALL, VESTIBULE, SANCTUARY.
REPAIR OR IN-KIND REPLACEMENT OF 2 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. REPAIR OR IN-KIND REPLACEMENT OF HOT WATER HEATER(S). LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), BASEMENT, KITCHEN.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: EDUCATION, RESIDENTIAL. START DATE: 9/25/2026. END DATE: 9/25/2027. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
DDS 2019 CBRC: ALTERATION OF EXISTING 3-STORY BUILDING INCLUDING CHANGE OF USE TO BUSINESS OFFICES AND FIRST FLOOR CAFE. PROJECT INCLUDES ADDITION OF ELEVATOR SERVING BASEMENT THROUGH 3RD FLOORS; ALTERATION OF ROOM LAYOUT AND ASSOCIATED MEP SYSTEM ALTERATIONS, INCLUDING NEW ROOFTOP DOAS UNIT. (OCCUPANCY GROUP B, A-2; TYPE III-B CONSTRUCTION) CONSULTANT REVIEWER: V3 COMPANIES OF IL
FOR PERMIT 101074273: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 8 SQ. FT., LINTEL QTY. 8, MAX. LENGTH 8. LOCATION: FRONT FACADE.
SPR 2019 CBC - PBC/DFSS/2FM - #10030: PILES (VERTICAL PENETRATION) ONLY FOR NEW CONSTRUCTION OF A 2-STORY SENIOR CENTER TO INCLUDE AT-GRADE PARKING (39 AUTOMOBILE PARKING SPACES), ORNAMENTAL FENCING, TRASH ENCLOSURE AND ASSOCIATED SITE WORK AS PER PLANS. (OCCUPANCY GROUP: A-3 / TYPE IIB CONSTRUCTION). CASE-ONS INCLUDED ON THIS PERMIT
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 6.75 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
DDS 2019 CBC. REVISION TO PERMIT #101075068 TO UPDATE THE FOLLOWING: REVISED TO REMOVE ROOFTOP PARK AND PEDESTRIAN BRIDGE, REPLACED ROOFTOP PARK WITH PARKING ON LEVEL 3, ADDED PARKABLE RAMP FROM LEVEL 2 TO LEVEL 3, ADDED CURB CUT ON MADISON ST, REVISED PARKING LAYOUT AT ALL LEVELS, ADD PARKING GARAGE CORE ON EAST SIDE, REVISED ELEVATOR CORE SIZE AND LOCATIONS, EXTERIOR WALL TYPES, LAYOUT OF TRASH AND RECYCLE ROOMS, ADDED TRASH CHUTE VENT TO ROOF, REMOVED WEDGE BARRIERS AT TOP OF LOADING RAMP, R