New shell warehouse building 58,150 SF. Type III-B construction. Scope of work includes concrete tilt panel construction and 1-hour rated SES and owners room. New (1) 2-inch domestic water and (1) electric meter. Requirements of 2024 IECC Section C406 were not addressed under this permit and will be required to be addressed as part of the future tenant improvement permit. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete cons
New shell warehouse building 58,150 SF. Type III-B construction. Scope of work includes concrete tilt panel construction and 1-hour rated SES rooms. New (1) 2-inch domestic water and (1) electric meter. Requirements of 2024 IECC Section C406 were not addressed under this permit and will be required to be addressed as part of the future tenant improvement permit. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete construction,
New 179,250 SF shell warehouse construction type V-B unlimited area building. Scope is shell building with attached fire separated pump house. New (1) 2-inch domestic water meter, (1) 1.5-inch landscape meter, and (2) electric meters. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete construction, masonry construction, soils, high-strength bolting, and post-installed anchors, ground-fault protection systems, conductors, and
AFP26-00653 THE PROJECT SCOPE INCLUDES MODIFICATIONS TO THE EXISTING 'D7' INFLATOR ASSEMBLY LINE (PMT23-12154) LOCATED IN THE PH. I / PRODUCTION AREA. EXIST. UTILITIES WILL NOT BE MODIFIED FOR THE PROJECT. EXIST. HAZARDOUS MATERIAL QUANTITIES WILL NOT BE INCREASED FROM THOSE PREVIOUSLY PERMITTED UNDER PMT23-12249.
AFP26-01281 - Like for like replacement of (6) automatic transfer switches.
Install 25,000 sf of high piled storage racking. Maximum storage height of 24 feet. Special inspection for anchoring. Approved with stipulations. See comments. Results in CoC.
AZ International Phase 3. On this phase, renovation of the facade and site development such as landscape, parking, and curbs where applicable. Deferred fire sprinklers and fire alarm. REF: other related permits status: PMT25-11905 - expired status since 5/6/26. Does not include gas meter - did not have sufficient info for gas meter (Provide gas ISO with pipe size, material, and developed length and btu demand. IFGC tb 402.4(5) PMT25-16671 - permit has not been issued and does not include gas m
Replace existing site chilled-water supply and return piping serving Buildings 510, 520, 521, 530, 531, 533, 540, 543, 560, 580, 581 and 591, including new isolation valves, building connections, trenching, backfill and site restoration. Install two new 200-HP tertiary chilled-water pumps at Building 541, associated pump pedestal, structural pipe supports and foundations, and electrical modifications. No new water meters. Special inspections for post-installed anchors, structural steel, concrete
INSTALLATION OF STORAGE RACKS REF: PMT26-11446 for bldg TI
New 201 SF, construction type II-B, F-1 occupancy sampling room expansion with requited 1-hour fire rated exterior wall. Scope includes renovations in the existing construction I-A, H occupancy building. Including unloading pump foundations and utility rack, electrical infrastructure upgrades, minor HVAC upgrades, removal of an existing overhead door, and infilling with 2-hour fire rated panels. Special inspection for fire-rated assemblies, steel, concrete, soils, and post-installed anchoring. D
Installation of new parking canopies in existing parking lot.
Installation of new parking canopies in existing parking lot.
Installation of new parking canopies in existing parking lot.
THIS PROJECT CONSISTS OF A NEW ONE-STORY 2,265 SF STEEL RAMADA AND AMENITY BUILDING THAT WILL INCLUDE RESTROOOMS, COVERED GATHERING SPACE, AND POOL EQUIPMENT SERVICE YARD. SCOPES INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING ELEMENTS. THE BUILIDNG IS AN EXPOSED STEEL STRUCTURE WITH STANDING SEAM METAL ROOFING, EXPOSED MASONRY WALLS AND AN OPEN BREEZEWAY THROUGH THE SPACE.
25'X55' semi-commercial swimming pool & spa w/pool & spa equipment. (2) lp gas heaters & (2) electric heat pumps. CMU equipment room & bathroom. 2000 gal under ground lp tank w/gas line to heaters & bbq. Water & electric to equipment room under separate permit.
Planning approved placing a 40-foot shipping container for storage at our Light Industrial property and directed me to obtain a building permit. The work is to set the container behind our office/warehouse.
New 12 inch looped fire line extension to provide service connections to Building 570 and a potential expansion.
like-for-like partial replacement - replacing ~24 inch section of original 2" polyurethane pipe using new 2" polyurethane pipe joined using couplings. Approved by Larry Snyder.
The purpose of these drawings is to support the permit application for a new outdoor dining area located beneath a portion of the existing covered patio. Project considerations include: A new fenced outdoor seating area is proposed, containing three dining tables. The total occupant load for the proposed restaurant, including the outdoor seating area, is lower than that of the previous establishment. Based on historical photographs and archived plans of the former restaurant, the previous occupa
Construction activities are not restricted in general, but outside noise attributed to construction is limited to the following hours: Regular Hours (October 16 – April 30) · Monday–Friday: 6:00 a.m. to 8:00 p.m. (5:00 a.m. for concrete pouring) Summer Hours (May 1 – October 15) · Monday–Friday: 5:00 a.m. to 7:00 p.m. (4:00 a.m. for concrete pouring) · Saturday: 7:00 a.m. to 7:00 p.m. Work that generates noise outside of these hours requires approval and an after-hours permit. After-hours
Two (2) new electrical services, switchgear cabinet, transformer and service entrance stations (SES) for each services with screening. (2) new electric meters. Installation of 8-foot-high masonry walls with gates at the west and east sides of the building to screen the electrical equipment. Special inspection for electrical, concrete, and masonry. Results in CoC.
New Freestanding 8,320 S.F. Office & Aircraft Hangar. Includes an 872 SF mezzanine. Type II-B Construction Type. Groups S-1 & B Occupancies. Includes a new 3/4-inch domestic water meter. This permit includes fire alarm sprinkler monitoring. 409 NFPA Group III Hangar. Special Inspections required for: Steel, Construction and Masonry. Deferred Fire Sprinklers. Results in CofO.
Completing the east half-street of Signal Butte Road from Germann Road to Pecos Road as well as Pecos Road from Signal Butte Road to 1,700-feet east along the frontage of the subject property. Improvements include AC pavement, curb/gutter, sidewalk, drainage, street lighting, signing/marking, and landscape/irrigation
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building C: 1-story, type II-B construction, 3,451 SF, group S-1 occupancy aircraft storage hangers. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for primary permit. REF: PMT24-01453 - Code modif
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building D: 1-story, type II-B construction, 13,692 SF, group S-1 occupancy aircraft storage hangers. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for primary permit. REF: PMT24-01453 - Code modi
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building B: 1-story, type II-B construction, 25,047 SF, group S-1 occupancy aircraft storage hangers and 7,216 SF, group B occupancy offices. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1.5-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for pr
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building A: 1-story, type II-B construction, 19,390 SF, group S-1 occupancy. Including fire sprinklers and fire alarm (sprinkler monitoring). The following operations are prohibited within the facility: Fuel transfers, Welding, Torch Cutting, Torch Soldering, Doping, Hot Work (e.g., welding, cutting, brazing, grinding), Spray Painting, Oxygen Service, Composite Repairs, Fuel System or Fue
New additional electrical service of 2,500 AMPS. Exterior electrical only, future TI under separate permit. New 2,500 AMP electrical meter. Special inspection for electrical at or over 1,000 AMPS. Results in CoC.
East yard TI of existing office space, building type IIA, with B occupancy. Modifications of 7,587 SF of non-structural interior walls, MEP's, and restroom reconfiguration. Deferred fire sprinklers and fire alarm. Results in CoC.
Foundation-only permit for a new top-running bridge crane rail system. Scope includes new reinforced concrete footings and associated anchorage. Crane rail support structure and baseplates will be a separate permit. Special inspection for soils, concrete and post-installed anchoring. Reviewed as noted. Results in CoC.