Search Permits
2,827 results · type: commercial
Remove existing sand (1,295 SF) and sidewalk (7,465 SF) at an existing City of Mesa park. New ADA ramp, sidewalk, park benches, and playground surfaces. New electrical provided for lights at future canopies. Existing electrical meter and panel 200A. Playground equipment and canopies to be installed under separate permits. Results in CofC.
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE TRAILER FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS APRIL 2027
Add Meter for new Equipment. REF: PMT21-11235 shell and suite CoO
Tenant improvement at first level in existing type I-A construction, group I-2 occupancy Banner Baywood medical center. Modification include demo of existing room and walls of adjacent rooms and install new walls, finishes and ceiling to create IDF room 100363, room and access reconfiguration of existing adjacent spaces and new millwork in tech lounge, convert exist storage room into IDF room 100233 with removal of ceiling and finish and associated MEP: relocation of exist water piping to jog ar
Install of 25ft flagpole in concrete footing with electrical lighting at Mission BBQ. Approved with comments. Results in CofC.
Install 24 Private Fleet Ev Charging Stalls Supported By (1) Pad Mounted Utility Transformer: (1) 4000a, 277/480v Mcb Switchboard: (3) Tesla Pre-Assembled Supercharger Units, Each With (1) V4 Supercharger Cabinet & (8) V4 Supercharger Posts
INSTALL 16 EV CHARGING STATIONS FOR PRIVATE USE SUPPORTED BY (1) PAD MOUNTED UTILITY TRANSFORMER: (1) 2500A, 277/480V MCB SWITCHBOARD: (2) TESLA PRE-ASSEMBLED SUPERCHARGER UNIT WITH (1) V4 SUPERCHARGER CABINET & (8) V4 SUPERCHARGER POSTS: (4) LIGHT POLES: (4) WASTE MANAGEMENT BINs
Replace fuse bucket electric panel C (part QMQB2032R) in SES cabinet: like-for-like. Special inspections required, Nationally Recognized Testing Laboratory (NRTL) required for reconditioned fuse bucket.
Requesting Certificate of Occupancy for hangar 101 at 2655 N Greenfield Rd, Mesa, AZ.
Add switches to existing SES and two building interior power panels
Requesting Certificate of Occupancy for hangar #113 at 2655 N Greenfield Rd, Mesa, AZ.
Design center in model and MHC
Requesting Certificate of Occupancy only for suite 205 at 2655 N Greenfield Rd, Mesa AZ.
Inground shotcrete commercial pool w/ associated recirculation equipment. Structural design per AMMTec Consultants, PLLC. All utilities (electric, water, sewer, gas, etc.) & barriers are the responsibility of the owner & are not part of this submittal.
Sales office in model and MHC
Requesting Certificate of Occupancy for Suite 105 at 2655 N Greenfield Rd, Mesa, AZ.
Commercial Building Permit
Commercial Building Permit
Off-site improvements along S. Signal Butte Road associated with Signal Butte Crossings, including roadway paving, curb and gutter, sidewalk, storm drainage improvements, street lighting, signing and pavement markings, landscaping, irrigation, and related utility coordination. New (4) 1-inch landscape meters. Landscape controllers are solar powered. Results in CoC.
New shell warehouse building 58,150 SF. Type III-B construction. Scope of work includes concrete tilt panel construction and 1-hour rated SES and owners room. New (1) 2-inch domestic water and (1) electric meter. Requirements of 2024 IECC Section C406 were not addressed under this permit and will be required to be addressed as part of the future tenant improvement permit. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete cons
New shell warehouse building 58,150 SF. Type III-B construction. Scope of work includes concrete tilt panel construction and 1-hour rated SES rooms. New (1) 2-inch domestic water and (1) electric meter. Requirements of 2024 IECC Section C406 were not addressed under this permit and will be required to be addressed as part of the future tenant improvement permit. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete construction,
Tenant improvement of existing 100,268SF type V-B construction building. Work to include exterior bldg demo of covered entry and its supported columns, planters, existing doors for renovation of entire south and west façade of building. Modifications include new exterior building lighting, new windows and entry towers. New 473 SF bldg addition with recessed loading dock with sump pump at north side of bldg and associated Mech elec and str. Special inspection req. - Steel, concrete, masonry, epox
INTERIOR ONLY: Demo roof top equipment, floor, stairs, ceiling, mezzanine, mechanical, and electrical at existing building. New stairs, MEP, and architectural. Exterior elevation modifications and outdoor patio by separate permit. Special inspections required for concrete construction, steel construction, and epoxy/expansion anchors. New 2 inch domestic water meter. New gas meter. New 1200A 3 phase electrical meter. Deferred roof truss and floor truss. Deferred fire sprinklers, fire alarm, hood
Install equipment screening for pump station. Special inspections required: steel construction, concrete construction, cast-in-place deep foundations. Approved as noted. Results in CofC.
Install gas line and pool heater at existing community pool. Approved as noted. Results in CofC.
Install 2025 NFPA 72 fire alarm system for a 2,400 SF A-2 lunch tent, including a conventional fire alarm control panel, linear heat detection, manual pull stations, and audible/visual notification appliances. Approved as noted.
Modify the existing captive air hood suppression system nozzles and appliances. Field inspection is required to verify that no modifications to the existing electrical or gas systems were made in conjunction with the appliance additions. Approved as noted.
Fire Alarm Control Panel replacement
The purpose of these drawings is to support the permit application for a new outdoor dining area located beneath a portion of the existing covered patio. Project considerations include: A new fenced outdoor seating area is proposed, containing three dining tables. The total occupant load for the proposed restaurant, including the outdoor seating area, is lower than that of the previous establishment. Based on historical photographs and archived plans of the former restaurant, the previous occupa
Pallet Rack Installation. Pallet Rack Installation. HPCS plan.