TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 10 SQ. FT., LINTEL QTY. 1, MAX. LENGTH 9. LOCATION: EAST FACADE.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 13.44 KW. ARRAY OUTPUT: 16.56 KW. INCLUDES 10.24 KWH ENERGY STORAGE SYSTEM. LOCATION: EXTERIOR, ROOF. ICC DISTRIBUTED GENERATION INSTALLER CERT. #23-0387.
INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 11.5 KW. ARRAY OUTPUT: 5.74 KW. LOCATION: INSTALLATION OF ROOF MOUNT SOLAR WITH BATTERY. ICC DISTRIBUTED GENERATION INSTALLER CERT. #22-0441.
FOR PERMIT B200472832: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
PURPOSE: NEW/REPLACEMENT INSTALLATION. WROUGHT IRON FENCE - 6'-0' ' (HEIGHT) X 60'-0' ' (LENGTH). CHAIN LINK FENCE - 6'-0' ' (HEIGHT) X 420'-0' ' (LENGTH). LOCATION: 6' FENCE -PERMANANT STEEL PICKET & CHAIN LINK W/SC.
ALTERATION OF EXISTING COMMUNICATION EQUIPMENT. ALTERATION OF 0 BOXES AND EQUIPMENT ON 1 TOWERS / STRUCTURES. LOCATION: EXISTING WIRELESS COMMUNICATION FACILITY.
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101071845. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: CITY FIRE ALARM BOX CONNECTION . SPECIFIC LOCATION: 4TH FLOOR.
SELF-CERT 2019 CBRC: ALTERATION TO EXISTING TENANT SPACE OF 800SF AT FIRST FLOOR KEEPING THE OCCUPANCY SAME AS GROUP-B (BUSINESS) FOR NON STRUCTURAL INTERIOR RENOVATION INCLUDING DEMOLITION & CONSTRUCTION OF DRY WALLS, CEILINGS, CASEWORK, PLUMBING, HVAC AND ELECTRICAL WORKS.
REPLACING EXISTING MONUMENT SIGN WITH A NEW MONUMENT SIGN READING ADVOCATE OUTPATIENT CENTER.
REPAIR OR IN-KIND REPLACEMENT OF 0 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS, EXTERIOR WORK, BASEMENT.
SCOPE: REPLACEMENT OF SUMP PUMP SYSTEM WITH ASSOCIATED CONCRETE REPAIRS, WITH ELECTRICAL FOR DEDICATED OUTLET. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS, BASEMENT.
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101085043. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 6TH FLOOR.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 24 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT.
FOR PERMIT 101082974: REPLACEMENT PLUMBING CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.