INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 11.9 KW. LOCATION: ROOFTOP OF BUILDING. ICC DISTRIBUTED GENERATION INSTALLER CERT. #16-0289.

12 W 44TH ST, Chicago
Jun 19

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.6 KW. ARRAY OUTPUT: 9.24 KW. LOCATION: ROOFTOP. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0250.

10052 S PRINCETON AVE, Chicago
Jun 19

TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 200 SQ. FT., LINTEL QTY. 7, MAX. LENGTH 12. LOCATION: EXTERIOR WALLS.

846 N LAVERGNE AVE, Chicago
Jun 19

PURPOSE: NEW/REPLACEMENT INSTALLATION. WOOD FENCE - 6'-0' ' (HEIGHT) X 132'-0' ' (LENGTH). LOCATION: FENCE ON BOTH SIDES OF HOME.

4835 N NEWLAND AVE, Chicago
Jun 19

ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: INSTITUTIONAL. START DATE: 7/1/2026. END DATE: 7/1/2027. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.

850 W IRVING PARK RD, Chicago
Jun 19

NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 14'-0' '.

12436 S NORMAL AVE, Chicago
Jun 19

TEMPORARY SCAFFOLDING: QTY: 1, MAX. LENGTH: 30 FT., MAX. HEIGHT: 40 FT. LOCATION: EXTERIOR FACADE. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT.

191 N WACKER DR, Chicago
Jun 19

IN-KIND REPLACEMENT OF EXTERIOR WINDOWS AND DOORS IN EXISTING OPENINGS. REPLACEMENT WINDOWS: 8; REPLACEMENT SKYLIGHTS: 0; REPLACEMENT DOORS: 2. AFFECTS: 2 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), LOCATION: EXISTING ELEVATIONS.

8414 S KINGSTON AVE, Chicago
Jun 19

NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.

9357 S PRAIRIE AVE, Chicago
Jun 19

NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-4' ' X20'-4' '. HIP ROOF HEIGHT TO PEAK: 4'-0' '.

5534 W HUTCHINSON ST, Chicago
Jun 19

REPAIR OR IN-KIND REPLACEMENT OF 12 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. INCLUDES REPAIR OR REPLACEMENT OF PLUMBING RISERS IN EXISTING CHASES. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), PLUMB REPAIR WORK, REPLACE PLUMB FIXTURES.

9717 S UNION AVE, Chicago
Jun 19

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 125 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: METER, EXTERIOR.

3442 W 84TH PL, Chicago
Jun 19

TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 672 SQ. FT., LINTEL QTY. 14, MAX. LENGTH 7. LOCATION: PARAPET WALLS AND STEEL LINTELS, FRONT AND SIDES O.

4955 W WASHINGTON BLVD, Chicago
Jun 19

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 40 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: BASEMENT.

3227 W FULTON BLVD, Chicago
Jun 19

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 3.8 KW. ARRAY OUTPUT: 3.52 KW. LOCATION: ROOFTOP OF BUILDING. ICC DISTRIBUTED GENERATION INSTALLER CERT. #16-0289.

6547 S EVANS AVE, Chicago
Jun 19

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 40 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT AND EXTERIOR ELECTRICAL SERVICE.

9735 S JEFFERY AVE, Chicago
Jun 19

TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 200 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: LEFT SIDE OF THE BUILDING.

139 W 113TH ST, Chicago
Jun 19

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 2 CIRCUITS. RECEPTACLE OUTLETS: 2 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: OUTSIDE SERVICE.

7524 S EMERALD AVE, Chicago
Jun 19

LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: MAIN AREA.

5261 W HARRISON ST, Chicago
Jun 19

SCOPE: NONSTRUCTURAL INTERIOR REMODEL OF MASTER BATHROOM. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), MASTER BATHROOM.

4348 N TRIPP AVE, Chicago
Jun 19

SCOPE: ROOF REPLACEMENT. AREA: 1800 SQ. FT. ROOF COVERING: ASPHALT SHINGLES. LOCATION: MAIN ROOF. IL ROOFING CONTRACTOR LICENSE: 104012900.

4101 N KIMBALL AVE, Chicago
Jun 19

NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X14'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.

7016 N TAHOMA AVE, Chicago
Jun 19

PURPOSE: NEW/REPLACEMENT INSTALLATION. VINYL/PVC FENCE - 6'-0' ' (HEIGHT) X 131'-0' ' (LENGTH). LOCATION: BACKYARD.

8537 W SUNNYSIDE AVE, Chicago
Jun 19

ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 6/19/2026. END DATE: 7/19/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.

555 W ADAMS ST, Chicago
Jun 19

FOR PERMIT 101077630: REPLACEMENT PLUMBING CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.

2059 W HASTINGS ST, Chicago
Jun 19

REPAIR OR IN-KIND REPLACEMENT OF 0 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. INCLUDES REPAIR OR REPLACEMENT OF PLUMBING RISERS IN EXISTING CHASES. LOCATIONS: 4 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), ALL FLOORS.

4212 N BERNARD ST, Chicago
Jun 19

SCOPE: ROOF REPLACEMENT. AREA: 1700 SQ. FT. ROOF COVERING: MINERAL - SURFACED ROLL ROOFING. LOCATION: FLAT ROOF. IL ROOFING CONTRACTOR LICENSE: 104003460.

3148 S CALUMET AVE, Chicago
Jun 19

SCOPE: ROOF REPLACEMENT. AREA: 2000 SQ. FT. ROOF COVERING: ASPHALT SHINGLES. LOCATION: MAIN ROOF. IL ROOFING CONTRACTOR LICENSE: 104012900.

2905 W DICKENS AVE, Chicago
Jun 19

LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. 10 KWH LITHIUM ION ENERGY STORAGE SYSTEM. SPECIFIC LOCATION: ROOFTOP.

8642 S LAFLIN ST, Chicago
Jun 19

INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 11.9 KW. LOCATION: ROOFTOP OF BUILDING. ICC DISTRIBUTED GENERATION INSTALLER CERT. #16-0289.

5217 S BISHOP ST, Chicago
Jun 19