Search Permits
2,919 results · type: commercial
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 110: 3706 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in CoO.
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 119: 3679 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 101: 3686 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 116: 3694 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.
Gas line repair. The existing regulator was replaced and pressure was verified by the contractor. All work to be verified by the inspector in the field.
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 104: 3704 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 113: 3709 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.
Addition and/or Alteration
Addition and/or Alteration
New Construction
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
New Construction
Addition and/or Alteration
CONVERSION OF GARAGE TO CONSTRUCTION OFFICE FOR MODEL COMPLEX. MODEL COMPLEX PMT21-03456. STIP: THIS HOME IS NOT TO BE INHABITED UNTIL THE CONSTRUCTION OFFICE (10839 E TAHOE AVE) IS CONVERTED BACK TO A GARAGE AND THE PARKING LOTS 195 (10857 E TAHOE AVE), LOT 196 (10863 E TAHOE AVE) HAVE BEEN CONVERTED BACK AND THE PARKING LOT IS NO LONGER NEEDED. GARAGE AREAS MODIFIED OR IMPROVED FOR THE PURPOSE OF PROVIDING A TEMPORARY OFFICE SHALL BE RESTORED BACK TO A GARAGE PER PARKING STANDARDS IN CHAPTER
Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. Water meter: 1.5-inch domestic. Special inspection required for soil, fabricator, steel, concrete, masonry, anchoring. Deferred fire sprinkler and fire alarms and steel joist. Results in CoC.
Modify the medium pressure steam flash tank and vent, the clean steam condensate flash tank and vent and the clean steam condensate pump piping modifications as needed. Results in CoC.
EXPEDITE - Install new 200 Amp-120/240V electrical service for the existing building. Results in CoC.
Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also be submitted prior to being issued a permit. This structure is to be restored like for like construction
Titan Alarm to install (2) relay for the shop fans
Addition and/or Alteration
Commercial Make Safe Permit
New Construction
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration