other_commercialC of o issued

Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 116: 3694 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east exterior wall. REF: PMT22-16896 main permit. Results in Coo.

4800 E FALCON DR 116, Mesa, AZ

Permit Details

Permit Number
PMT26-07776
Type
other_commercial
Status
c of o issued
Issued Date
May 19, 2026
County
Mesa, AZ
View on county site

Parties

No contractor listed

About other_commercial Permits in AZ

0

other_commercial permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

New single-story custom home and ADU with 7938 SF livable and 2967 SF non-livable area. Livable area consists of 7073 SF main residence and 865 SF detached ADU. Non-livable area consists of a four car garage, covered patios and a covered entry. Type V-B construction. Existing 1 inch water meter. New 600 amp SES. New gas meter and new sewer connection. Deferred fire sprinkler calculations and truss calculations. Special inspections required for structural welding, high strength bolts, concrete co

3829 E HUBER ST · PMT26-10492

Onsite and Offsite Improvements for Haven at Hawes. Includes (1) 1-inch Pool Meter, (1) 2-inch Landscape Meter and (1) 1" Landscape Meter. 1-inch Domestic services and BFP for each lot, (1) 200 AMP, and (1) 100 AMP electric meter. Deferred electric vehicle gates. Special inspection for post-installed anchors, concrete, and masonry. Reviewed with comments. Results in CoC.

4065 S HAWES RD · PMT26-06671

Install of SES and transformer with (4) level 2 vehicle charging and (4) future level 3 vehicle charging, and 8" concrete pad for 560 SF factory -built guard house at east staging lot next to Bldg 4. Permit excludes factory-built buildings. Special inspection require - Elect over 1,000amps, concrete and anchors. REF: PMT26-01846 Bldg 4. Approved with comments. Results in CoC.

7237 E PECOS RD · PMT26-09973

Tenant improvement for existing (2) story 490,782 SF shell space data center, Group B/S-1/S-2 occupancy, Type I-B Construction. Modifications of existing 1st level warehouse into 3 data halls. Special inspection req. - Steel, concrete, soils, deep foundations, spray fire resistance material, fire caulking, Mastic & intumescent coating, smoke control. REF: PMT24-02625 Civil, PMT24-09780 Shell, PMT24-11335 Phase 1. Results in CoO at completion of all phases. Result in TCO. Phasing plan.

3856 S EVERTON TERR · PMT24-19524

Similar other_commercial Permits

Our project involves the design, installation, and commissioning of an Emergency Responder Radio Coverage System (ERRCS) within an existing building. The system will ensure reliable in-building radio coverage for first responders by amplifying public safety frequencies. Key tasks include integrating donor antennas, bi-directional amplifiers, and distributed antenna networks throughout the building

Mesa, AZ · PMT26-10697

COB26-00053 - Create a maintenance storage shed in rear of property. Size approx. 288 sq ft 12x24

Mesa, AZ · PMT26-04822

The contractor is planning to install temporary portable generators on-site. The master plan has already been approved, under PMT24-15709 and the temporary generators will be in place for a duration of 3 to 4 months until permanent power is available. The temporary portable generators will be utilized for commissioning activities to facilitate an early start-up of all mechanical and electrical systems.

Mesa, AZ · PMT26-13074

Install new electrical 200A sub panel fed from existing unused meter and fused disconnect at an existing building. Results in CofC.

Mesa, AZ · PMT26-11833

Install a new fire alarm system consisting of an addressable fire alarm control panel, (2) 12V batteries, and communicator with (1) photoelectric smoke detector, (1) pull station, (5) ceiling-mounted horn/strobes, (2) ceiling-mounted strobes, tamper and water flow switches, and various modules for hood suppression and CO2 monitoring supported by a new notification appliance circuit.

Mesa, AZ · PMT26-12241

About other_commercial Permits in Mesa, AZ

What is a other_commercial permit?

A other_commercial permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.