Tenant improvement of fire sprinkler for suite 5
Tenant improvement fire sprinkler suite 6
New data center civil site improvements. Installation of all off-site improvements and street frontage landscaping during the first phase of construction. Water Meters: (1) 2-inch Landscape meter. Deferred vehicle access gates. REF: PMT26-08422 Bldg 2. Approved with comments. Results in CoC.
Modify existing fire alarm system by adding (5) ceiling-mounted horn/strobes, (2) ceiling-mounted strobes, (1) duct smoke detector, and relay for hood fire suppression. Related to PMT26-00272. Results in CoC.
Install canopy over existing Falcon-1 switchgear inside Falcon Substation.
Interior modification to existing baler/process area. Construct new 8-inch CMU wall and associated concrete curb to provide a 1-hour fire-resistance-rated separation between the existing F-1 Baler Room and H-3 Extruder/Open Process Area. Work includes demolition of existing door/wall components, modifications to existing openings, relocation of affected equipment/controls, and associated structural work. Existing building is Type II-B construction and fully sprinklered. Special inspections requi
Temporary Backup Generator for Sprouts Farmers Market until SRP power connection is complete. Tenant Improvement permit: PMT25-17100
Emergency Responder Radio Communication System
Add Meter for new Equipment
A new 20,400 s.f. storage building and boat testing tank
Construction, repair, remodeling, demolition, and excavation work may be conducted between 6:00 a.m. through 7:00 p.m. Monday through Friday and 7:00 a.m. through 7:00 p.m. on Saturday. Work outside of this timeframe requires an afterhours/noise permit. After Hours permits for construction are subject to the following conditions and Building Official approval: A. The applicant must provide the following information: 1. Location of work: 3441 S. 80th St. Mesa, AZ 85212 2. Schedule of hours and da
Engineered repair of (5) damaged joists in suite H. Special inspection for repair observations, welding, wood framing. Results in CoC.
Install 8-foot iron fence with (5) manual truck gates and (1) pedestrian gate with free egress around loading dock area of existing building. Results in CofC.
New PV system on rooftop of an existing building. Install (182) new PV array panels, (1) AC combiner panel, (1) Alsoenergy DAS, (3) PV power inverters, (1) 400A utility disconnect switch, and (1) new 320A 3 phase PV electrical meter. Results in CofC.
Install of new 420 SF, type III-B, group U occupancy free standing aluminum shade structure over existing bldg rear entry/exit. Shade canopy is 15ft x 28ft with (6) posts with footings. ADM26-00630 approval for site modification for addition of shade structure. Results in CoC.
This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. D
POTHOLING utilities for design and discovery
New one-story parish office building that replaces the current facility to serve the existing campus. New building program includes: public lobby vestibule, conference rooms, breakroom, private office spaces for administration offices as well as private offices for adult-religious education offices, a teen life classroom. All existing fire lanes remain and existing entry / exit driveways remain. Minor landscape and site development includes: new concrete sidewalks and points of connection to ent
Demolish exiting light pole in ROW. Install new light pole, wireless equipment, and 100A single phase pedestal electrical meter. Approved as noted. Results in CofC.
Install sensor release electronic locking systems on (3) egress doors at the office of a new hanger building (PMT23-04321). Approved as Noted. Results in CofC.
Electrical infrastructure upgrade for the whole park.
Modify existing Notifier fire alarm system for replacement AHU and associated shutdown interface. Approved as noted.
Install new equipment screening at new City of Mesa pump station. Special inspections required: steel construction, concrete construction, cast-in-place deep foundations. Approved as noted. Results in CofC.
PROPOSED HOTEL WITH ONSITIE PARKING, WATER, SEWER, DRAINAGE INFRASTRUCTURE. IN ADDITION TO CIVIL INFRASTRUCTURE, THE SITE IMPROVEMENTS WILL ALSO INCLUDE LANDSCAPE ARCHITECTURE, SITE AMENITIES, SCREEN WALLS, STRUCTURAL RETAINING WALLS AND PRIVATE PARKING LOT STREET LIGHTING.
Fire Alarm - connection of duct smoke detectors to shell FACP for offiste reporting.
Install (2) new shade structures (952 SF total) at playground area of an existing City of Mesa park. Electrical power to shade structure lighting under site improvement permit (PMT26-05268). Playground equipment installed under PMT26-15046. Results in CofC.
Installation of electrical power additions * PER Hadrian's agreement with the City of Mesa: 18 Day 1st review and 10 Day 2nd review NO EXPEDITE FEES CHARGED
Replace fire sprinkler system for riser 7 and for RP7 first floor only
Phase 1 and Phase 2 civil drawings for overall site.
Install CO2 monitoring system with horn strobes. Existing CO2 tank.