PermitDig

Search Permits

248,074 results

Installation of 26kW backup generator tied to existing gas & electric

7260 E EAGLE CREST DR 45, Mesa
Nov 6

Installation of temporary protective construction fencing along the approved limits of disturbance for a new Single Family Residence at 8717 E Regina Circle Lot 33 in Mesa AZ. Fencing will be installed in accordance with the approved site plan and City of Mesa.

8717 E REGINA CIR, Mesa
Nov 6

Upgrade equipment at existing Verizon Rooftop Site

101 W MAIN ST, Mesa
Nov 6

Upgrade suite panel form 100 120/208V to 200A 120/208V

624 W BROADWAY RD 216, Mesa
Nov 6

I would like to fully enclose my patio into a livable space. The plan would be to use the existing roof and insulation/drywall off of the block wall. The existing roof is attached to the brick wall via embedded steel anchors and connected to the side of the house via horizontal ledge board. There is metal flashing between the wall and roof. There would be some glass block but no traditional windows, adding a door on the north side of the patio for the 2nd egress point.

1500 W RIO SALADO PKWY 116, Mesa
Nov 6

Installation of 13.50 kWh Battery

11518 E ENROSE ST, Mesa
Nov 6

Demo existing pool and build new pool and sap Install propane tank and gas line

3731 E MENLO ST, Mesa
Nov 6

adding battery to existing system

7116 E GREENWAY ST, Mesa
Nov 6

Dutch Bros Signage

1230 S MESA DR, Mesa
Nov 6

THE PROJECT CONSIST OF THE INTERIOR RENOVATION OF THE KITCHEN AND DINING AREA, AND THE STAFF ROOM. NO SQUARE FOOTAGE ADDED.

22 W 9TH PL, Mesa
Nov 6

Installation of one set of LED front-lit pan channel lettersets mounted to the building SWEET REPEATS 37 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.

6321 E SOUTHERN AVE, Mesa
Nov 5

Installation of non illuminated flat cut out lettering & logo

Unknown, Mesa
Nov 5

NEW RETAIL BUILDING FOR THE USE OF GOODWILL STORE AND DONATION CENTER ON NEW SHOPPING CENTER DEVELOPMENT LOCATED AT THE INTERSECTION OF GREENFIELD ROAD AND BASELINE ROAD IN MESA,ARIZONA. THIS PROJECT WILL INCLUDE A DRIVE-THRU DONATION LANE FOR RECEIVING DONATIONS. THIS STORE WILL PROCESS THE DONATIONS AND PROVIDE ITEMS FOR RE-SALE TO THE PUBLIC. Per Conditions of Approval of ZON25-00967 Replace all dead or dying landscaping at the parking area and perimeter of the project site. Deferred fire sp

1855 S GREENFIELD RD, Mesa
Nov 5

New 550 sf livable bedroom and office addition at existing SFR. Special inspections required for drill & epoxy. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.

2353 S REVERE, Mesa
Nov 5

R-4 OCCUPANCY GROUP CONDITION 1. Community Residence Registration Application and Certificate of Occupancy for a residential care home operating as a Behavioral Health Home. Name: Holistic Behavioral Health LLC. Applicant requested 7 number of residents. MZO allows up to 10 residents, excluding staff. No skilled nursing services. 24-hour care. R-4 Occupancy Group Condition 1. MBC 310.5: This occupancy condition shall include buildings in which all persons receiving custodial care, without any a

11341 E UNGER AVE, Mesa
Nov 5

COD26-03284 Asbuilt Interior remodel non structural.

1408 E 3RD ST, Mesa
Nov 5

Offsite road improvements for E. Starfire Ave. west of S. Ellsworth Rd.

8759 E STARFIRE AVE, Mesa
Nov 5

Tenant Improvement. Deferred fire sprinklers.

6859 E REMBRANDT AVE 101, Mesa
Nov 5

Construct new 3,805 SF livable single-story custom home with 1,233 SF non-livable. Type V-B construction. Existing structure demolition under PMT26-09724. New driveway cut, Existing 1" water meter to remain. New 400 amp electrical service and gas meter. Deferred roof truss calculations. Special inspections required for concrete construction including post-tensioned slab-on-ground foundation, soils and post-installed anchors. Minimum required building inspections: Plumbing underground, footing, s

3354 E FOX ST, Mesa
Nov 5

Install 200-amp sub-panel on exterior of metal garage for the existing residence. Distribution sections, new feeders, grounding and bonding, and reconnect existing branch circuits. No other utility changes. No deferred items. No special inspections. Minimum required building inspections: Electric rough in and electric final.

640 E NANCE ST, Mesa
Nov 5

Install gas line and pool heater at existing community pool. Approved as noted. Results in CofC.

1744 S 82ND WAY, Mesa
Nov 5

Install (2) LED illuminated monument signs at separate entrances to a new gas station and convenience store (PMT25-16712). Install (2) LED illuminated pan-channel letter/logo signs on the fuel canopy and (1) LED illuminate pan-channel letter sign on the building. Disconnect switches for the monument signs and power to all signs provided under store and fuel canopy construction permit (PMT25-16712). Results in CofC.

10744 E ELLIOT RD, Mesa
Nov 5

Installation of back up generator, automatic transfer switch Gas line for generator

1150 N COUNTRY CLUB DR 12, Mesa
Nov 5

CONSTRUCT A 338 SF SWIMMING POOL & 49 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 70-FT OF 2-INPE GAS LINE BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER AND WOOD BURNING FIRE PIT. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGH

5818 S HASSETT, Mesa
Nov 5

Attached 574 Sq Ft ADU with 22 Sq Ft covered patio

2539 E GLENCOVE ST, Mesa
Nov 5

PLUMBING PERMIT FOR HALL BATHROOM. TUB TO SHOWER CONVERSION WITH 60 X 30 STANDARD PREFORMED SHOWER BASE, NODRAIN RELOCATION, NO STRUCTURAL CHANGES. WALL SYSTEM TO 81-IN CEILING HEIGHT, THREE CORNER SHELVES, GRAB BAR, AND SHOWER. MAIN BATHROOM TUB TO TUB REPLACEMENT WITH 60 X 32 LEFT DRAIN TUB, NO DRAIN RELOCATION, NO STRUCTURAL CHANGES. WALL SYSTEM TO 86-IN CEILING HEIGHT, THREE SHELVES, GRAB BAR, AND SHOWER ROD. NEW INSTALLATIONS WILL TIE INTO EXISITING PIPING. NO CHANGE TO OVERALL SQUARE FOOTA

449 E 3RD ST, Mesa
Nov 5

Group A-2 occupancy. Type V-B constructions. 2,199 SF. Occupant load 53. Restaurant suite build out in new shell building. New gas meter. New architectural and MEP. Special inspections required: Grease duct fire wrap and leak test. Deferred hood AFES. Results in CofO.

3461 S ELLSWORTH RD, Mesa
Nov 5

New 630 SF detached ADU and an attached 441 SF covered patio. Includes MPE improvements.

1309 N AMANDES, Mesa
Nov 5

Install new storage racks in an existing warehouse suite for high-piled combustible storage. Special inspections required: post-installed anchors. Approved as noted. Results in CofC.

8016 E PECOS RD, Mesa
Nov 5

Installation of 13.50 kWh Battery

33 E MCLELLAN RD, Mesa
Nov 5