Search Permits
245,623 results
Construct interior alterations to bathroom for one family dwelling subject to field inspection STFI.
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
Install Low Voltage Bulk Co2 Montoring System. Plug And Play System, No Mechanical, No Structural And No Electrical Work.
CONSTRUCT A NEW 188 SF LIVABLE ADDITION WITH ELECTRIC. PERMIT EXISTING UNPERMITTED 111 SF SHED WITH ELECTRIC AND PLUMBING. MINIMUM OF TWO 9-FT X 18-FT UNOBSTRUCTED PAVED, 2-IN ASPHALT OR 4-IN CONCRETE, PARKING SPACE REQUIRED BEHIND FRONT SETBACK WITH A MINIMUM OF ONE COVERED. 68-FT X 79-FT INTERIOR CORNER LOT. MINIMUM SETBACKS ARE 5-FT FRONT, 10-FT REAR, 5-FT SIDES. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. REF. HOST PERMIT 124069 FOR EXISTING MANUFACTURED HOME, GARAGE
Tub to Shower Conversion in Master Bathroom at existing SFR - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.
Install of a 1hr demising wall (between gridline 8 and 9)in existing type VB construction, B and S-1 occupancy shell bldg. REF: PMT22-15547 Bldg A Shell. Deferred fire sprinklers. Results in CoC.
CONSTRUCT A 403 SF SWIMMING POOL NO SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
Upgrade existing 200-amp residential electrical service to a new 400-amp residential service in accordance with SRP service design and City of Mesa requirements at existing SFR. Work includes installing new 400-amp main panel and relocation of service equipment and meter to the west side of the attached garage, as well as turning the existing 200-amp panel at the east side of the home into a sub-panel.
Type x construction. 1,930 SF. Group B occupancy. Occupant load 15. Demo slab at new restroom and shower area. Remove viewing window at office and infill. New partition walls to create treatment rooms. New ada compliant restroom and roll-in shower. New refrigerator and microwave at employee break area. New residential style washer and dryer in worker back area. New architectural and MEP. Results in CoO.
RELATED TO COB26-00035 8382 SF interior remodel of the existing two-story single family residence and existing attached ADU consisting of 5536 SF at the first floor and 2846 SF at the second floor. Existing exterior footprint, roof structure and foundation to remain. Existing 1.5 inch water meter to remain. Existing 400 amp SES with electrical modifications. Separate demolition permit required for demolition work. Type V-B construction. No deferred items. Special inspections required for epoxy a
Tenant improvement in existing 4,982 SF, type II-B construction, group B occupancy suite. Modifications include new demising wall to split suite, minor demo and new partitions in exist occupied suite, new millwork and finishes and associated MEP scope. Deferred fire sprinklers and fire alarms. Access Control to be under a separate submittal. Remaining suite to be vacant/unoccupied. Results in CoO.
Whole-home rewire. 200A service at existing SFR.
CONSTRUCT A 371 SF SWIMMING POOL INSTALLATION OF TWO OF 22-GALPROPANE TANKS BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & FPD 6104.1. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE
Tenant improvement in existing 24,885 SF, type III-B, B and S1 occupancy office warehouse suite. Modifications include new interior non loadbearing wall in warehouse and part of office area to create a 7,300 SF, B occupancy showroom, ductwork at office area and warehouse from exist RTU, added ceiling areas, new electrical panel for new lighting and receptacles at the showroom area. Special inspections required for concrete. Sprinkler plans are required if adding or relocating 10 or more fire spr
Build a detached garage: 988 S.F. Includes Mechanical and Electrical improvements.
Single family detached Dream Finders Homes Plan 4 master plan application Master plan for new 2303 S.F livable, 715 S.F. non-livable. 2 story - single-family home construction. Type V-B construction. R-5 occupancy. New ¾” water and 200 amp electric meter. New gas meter. Special inspections required for post-installed anchors in PT slab, reinforcing steel-prestressing tendons. Truss Calcs and fire sprinklers deferred. EV-Charger in garage.
Group B Occupancy. Type V-B Construction. 3,500 SF. Occupant load 37. Existing grey shell building. New partition walls to create offices, exam rooms, break room, 2 ADA compliant restrooms, and lobby. New mechanical ducting, diffusers , return air grills, and smoke detectors for 3 - existing heat pumps on the roof. New water supply lines, associated plumbing equipment, and waste lines. New dental vacuum system with amalgam separator. New 400A 3 phase electrical meter. New architectural and MEP
New 2309 SF single story residence with a 2+ car garage at Hawes Crossing. Includes water, electric and gas meter. Special inspections for post tension slabs **SEE ADDENDA MST25-07605**