Search Permits
245,623 results
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
unknown
New Storage Room Under Flex Room - Related To 180025
New Detached A D U With Deck
Attached A D U; Convert Unfinished Lower Level To Living Space; Convert Part Of Upper Floor To A D U - B W O P
Legalization Of As Built Existing Conditions. Total 5940 Sqft. And Exterior Decks
Upgrades To (E) Cell Tower - T Mobile
Water Damage Repair Limited To Lower Level. Like-For-Like Restoration. Construct (N) Retaining Wall Under Entry Deck.
Residential Electrical Repair Like for Like-no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit.
New 125A Main Lug Only Subpanel in rear workshop + 17-ft trench at existing SFR. Reference: COD26-04085 - ramps being used to access workshop at rear.
242 SF remodel converting the existing covered patio to livable area. Type V-B construction. No upgrade to utilities. Minor electrical work. No deferred items. No special inspections. Minimum required inspections: Footing, stem, strap/shear, frame, insulation, drywall shear, electric rough in, electric final, and final. If needed, underground plumbing.
PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF
Install new equipment for a new public potable water well site. New 1.5-inch landscape water meter service and 1.5-inch landscape water meter. New electrical 400A 3 phase meter. Deferred precast concrete structures, pre-engineered buildings, sound enclosures, and shade structures. Special Inspections Required: electrical, steel construction, concrete construction, masonry construction, and soils. Results in CofC.
Addition of 109 sq ft kitchen with full interior remodel with new exterior windows at existing SFR. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.
Install new illuminated canopy signage on north elevation with MARATHON logo canopy sign with 42.5 blue dimensional ACM. Install on west elevation MARATHON wordmark canopy sign with 64.20 blue dimensional ACM. Install on east elevation 2.5 stripe banner sign with 71.5 blue dimensional ACM. Install south elevation MARATHON logo canopy sign with 45' blue dimensional ACM. Also including in this permit Refacing existing monument sign
Install one ONE non-illuminated building mounted wall sign, on the east elevation of the building 99 sq ft LOGO ESSENTIAL TURBINES.
Northwest wall Reface existing 10' x 24' non-illuminated panel sign. Install 5' Beechcraft lighted channel letters CESSNA BEECHCRAFT BY TEXTRON AVIATION on northwest and northeast wall. Remove existing PCL's and replace with new PCL's. Remove 8' x 8 Cessna icon. Southeast wall Remove existing CESSNA/CITATION PCL's and replace with PCL's. Southwest wall Remove only 8' x 8' CESSNA icon.
NEW 2129 SF SINGLE STORY RESIDENCE WITH A TWO CAR GARAGE AND STORAGE ROOM FOR TAPESTRY AT DESTINATION. INCLUDES ELECTRIC, GAS AND WATER METERS. SPECIAL INSPECTION FOR POST TENSION SLABS. SEE MST22-09300 EXPAND STORAGE WIDTH 2' TO PROVIDE TURN IN TO SINGLE CAR BAY. ADDENDA MST23-01917 1.REVISED NEW STANDARD CONFIGURATION TO BE 8080 SDG: 2. REVISED TO ADD OPTIONAL 9080 MULTI SLIDE 3. REVISED TO ADD OPTIONAL 9080 MULTI POCKETING DOOR