New Storage Space Within Garage. New Pantry And Wine Celler Within Footprint. B W O P
Retaining Wall, Fencing, Gate
(N) Detached Garage For Existing Single Family House.
Structural Repair Of Exterior Wood-Framed Bearing Wall
Foundation Repair Using 30 Push Piers.
(N) 1625 Kw Natural Gas Exterior Fuel Cell System
Replace beverage equipment and associated MEP with new. Demo identified equipment, drains, water lines, refrigeration lines, and floor sinks. Remove power back to electrical panel for demolished equipment. Install new equipment, waste lines floor sinks, water lines, beverage lines, power for new equipment. Replace existing RTU glycol chiller condensing unit with new. Results in CofC.
Install (4) exterior wall mounted signs. South, north, east and west elevations pan channel letters - LOGO KAINOA'S HAWAIIAN FUSION - 3 signs at 72 sq ft each and one at 14 sq ft east elevation. Total sign area 230 sq ft.
Replace beverage equipment and associated MEP with new. Demo identified equipment, drains, water lines, refrigeration lines, and floor sinks. Remove power back to electrical panel for demolished equipment. Install new equipment, waste lines floor sinks, water lines, beverage lines, power for new equipment. Replace existing RTU glycol chiller condensing unit with new. Results in CofC.
Civil improvements to existing site entrance at the MSA Data Center, to include driveway widening, additional parking expansion and install of (2) Pre-Engineered Metal Bldgs.: (32 SF) Guard Shack and (393 SF) Trucker Driver Shelter. Scope to include associated site lighting relocation and new elect panel from exist generator. Special inspection req. for soils and concrete. Results in CoC.
Group B occupancy. Type I-A construction. 1,504 SF. Occupant load 12. New spec suite build out in new building. New partition walls to create ADA compliant bathroom and storage/electrical room. New architectural and MEP. New mechanical indoor split system heat pump unit, new supply air ducts, diffusers, condensate drain line, and return air grille. New plumbing fixtures, waste lines, and water supply lines. New 200A 3 phase electrical meter. Deferred fire alarm and fire sprinklers. Results in Co
Replace beverage equipment and associated MEP with new. Demo identified equipment, drains, water lines, refrigeration lines, and floor sinks. Remove power back to electrical panel for demolished equipment. Install new equipment, waste lines floor sinks, water lines, beverage lines, power for new equipment. Replace existing RTU glycol chiller condensing unit with new. Results in CoC
Interior tenant improvement for Fun City, consists of alteration of an existing commerical tenant space to an entertaiment facility. Scope includes new partitions, new equipments, installation of new lighting fixtures, new receptacles, new electrical connection of equipments, intallation of toilet room ventilation, new restroom plumbing fixtures, water connection to new toilet fixtures. Deferred fire sprinklers and fire alarms.
Demo existing kitchen equipment and waste lines at area of work to occur. Demo existing Type I hood, associated ducting, and roof top exhaust fan. New Captive Air Type I kitchen hood exhaust system, fire suppression system, grease duct, and associated equipment. New roof top exhaust fan and grille. Trench for new floor sink tie new waste line into existing grease waste line. New vent from floor sink to ceiling and tie into nearest existing vent through roof. New exhaust fan for relocated combin
Single family detached Dream Finders Homes Plan 2 master plan application Master plan for new 1801 S.F livable, 587 S.F. non-livable. 2 story - single-family home construction. Type V-B construction. R-5 occupancy. New ¾” water and 200 amp electric meter. New gas meter. Special inspections required for post-installed anchors in PT slab, reinforcing steel-prestressing tendons. Truss Calcs and fire sprinklers deferred. EV-Charger in garage.
Dream Finders Homes Plan 3 - Master Plan – New Two Story Single Family Residence – Total livable area 2178 SF and total non livable area 703 SF. Type V construction. R-5 occupancy. New three quarter inch water meter, gas load 449000 BTU, and 200 amp electrical panel. Deferred submittals: truss drawings and fire sprinklers. Special inspections required for steel construction, concrete construction, and soils. Deferred Truss Calcs, and sprinklers. EV-Charger in garage.
Install irrigation system related to PMT23-14420. Landscaping to comply with approval of BOA23-00397. Results in CoC.