RELATED TO COB26-00026 Fire damage repair and remodel of existing residence. New 399 SF non-livable carport, conversion of 500 SF existing garage to livable space and 360 SF existing patio to livable space. Replace existing electrical panel, ductwork, and fire damaged plumbing, electrical and mechanical systems. Structural repairs include replacement of approximately seven fire damaged roof trusses, interior wall framing and existing glulam beam per engineered repair plans. Type V-B construction

1952 N ACACIA, Mesa
Oct 16

LENNAR #3524 HAWES CROSSING VILLAGE 1 - WOOD FRAMED 2549 SF TWO STORY RESIDENCE WITH A 2 CAR GARAGE, COVERED PATIO AND COVERED PORCH. INCLUDES NEW GAS, WATER AND ELECTRICAL METER. ADDENDA MST24-14771 - USE PRODUCT IN PHASE 2 AND UPDATE REVISED STRUCTURAL SHEETS FOR PHASE 2.

8336 E PETRA AVE, Mesa
Oct 16

Construction of new attached ADU at rear of existing dwelling 635 sqft with new subpanel 100A, electrical, mechanical and plumbing. Remodel 305 SF of existing livable at Master BR & Bath. Add 627 SF new livable addition with electric fireplace at front of existing residence. Remove existing 180 SF rear covered patio. Special Inspections Certificate Epoxy & Deferred Prefabricated Wood Trusses.

2543 E JUANITA AVE, Mesa
Oct 16

Installation of one set of front-lit pan channel lettersets and logo box, flush-mounted to the building 46 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.

6341 E SOUTHERN AVE 108, Mesa
Oct 16

Install (2) LED illuminated channel logos and letter display, north elevation w/logo ASHLEY 100.85 sf, south elevation w/logo ASHLEY 154.58 sf. Replacement of tenant faces.

6233 E SOUTHERN AVE, Mesa
Oct 16

Upgrade existing 200A SES to new 400A SES underground service. Minimum required building inspections: Electric rough in and electric final.

2543 E JUANITA AVE, Mesa
Oct 16

Group A-3 occupancy. Type V-B construction. 6,535 SF. Occupant load 121. Existing warehouse suite being converted to indoor badminton courts. Existing office and (2) ADA compliant restrooms. Install (2) new mechanical HVAC RTUs, new supply air ducting, and supply registers. Replace existing drinking fountain with new hi/low drinking fountain. New electrical roof top receptacle and HVAC connections. Less than 15 fire sprinklers will be added/relocated. Results in CofO.

2150 W BROADWAY RD 108, Mesa
Oct 16

Install (1) temporary vinyl banner while awaiting permanent signage

1146 N ALMA SCHOOL RD 116, Mesa
Oct 16

Shell building constructed under PMT24-18572 (approved shell plans are with PMT23-03205). New plumbing washer boxes and waste line. (24) new mechanical heat pump RTUs and condensate drain lines. (3) new electrical meter 200A 3phase, receptacles, and lighting. Special inspections required: steel construction and post-installed anchors. Deferred fire sprinklers. Approved as noted. Results in CofC.

9524 E GERMANN RD 101, Mesa
Oct 16

Group B and S-1 occupancies. Type III-B construction. 34,354 SF. Occupant load 76. Install new demising wall to create a new suite in a new grey shell warehouse building. Install new partition walls to create new office area in the new warehouse suite. Shell building constructed under PMT24-18572 (approved shell plans are with PMT23-03205). (2) ADA compliant restrooms, breakroom, reception area, conference room, and offices in the new office area. (2) ADA compliant restrooms, janitors closet, an

9520 E GERMANN RD 101, Mesa
Oct 16

PERMIT IS ONLY FOR INSTALLATION OF ONE LG RESU 16H PRIME BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

2635 N MOUNTVIEW RD, Mesa
Oct 16

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE

2302 W NOPAL AVE, Mesa
Oct 16

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 EXPANSION BATTERY TO EXISTING POWERWALL3 SYSTEM. REFERENCE PMT 25-16796. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY S

11229 E ULYSSES AVE, Mesa
Oct 16

New 400 SF non-livable attached covered patio addition. Type V-B construction. No electrical work. No utility changes. No deferred items. No special inspections. Minimum required building inspections: Footing, strap/shear, framing and final.

2926 S EMERSON, Mesa
Oct 16

CONSTRUCT A 431 SF SWIMMING POOL & 49 SF SPA. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".

6523 E PRESIDIO ST, Mesa
Oct 16

Addition of approximately 210 Sq Ft Walk in Closet including new steam shower. Minimum required inspections: Footing, stem, strap/shear, frame, insulation, drywall shear, mechanical rough in, electric rough in, plumbing rough in, mechanical final, electric final, plumbing final and final. If needed, underground electrical and plumbing.

2563 N PIONEER, Mesa
Oct 16

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE

523 N ASHLAND, Mesa
Oct 16

Construction of a new detached, single-story, 400-square-foot Accessory Dwelling Unit (ADU) on an existing single-family residential property. The new ADU will include one bedroom, one bathroom, kitchen, living area, closet, and laundry area, along with associated structural, electrical, plumbing, and mechanical work. The project includes new foundation, wood-framed walls, roof structure, exterior stucco finish, roofing to match the existing residence, windows, doors, and all required utility co

155 N SPENCER 101, Mesa
Oct 16

Replacement of 200 Amp (or less) electric panel - no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. THE ACT OF SELF DISCONNECTING UTILITY WIRES OR METERS IS PROHIBITED AND MAY CAUSE DAMAGE OR INJURIES. Failure to schedule disconnect may result in additional utility trip charge fees and charges for any damage to utility equipment. Please contact your applicable utility (either SRP at 602

566 W MEDINA AVE, Mesa
Oct 16

Existing 200A electric service panel to be replaced with a 200A all-in-one electric service panel at the same location. Complete rewiring of the home is included. Minimum required building inspections: Electric rough in and electric final.

6946 E FLORENCE LN, Mesa
Oct 16

Replace storm damaged SES and house panel. Install new electrical meter. Special inspection required for electrical work. Reviewed as noted. Results in CoC.

7343 S 89TH PL, Mesa
Oct 16

Install battery backup system AC coupled with existing solar

3211 N SAFFRON, Mesa
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.Install (18) roof mounted solar panels, (18) Enphase Micro Inverters, (1) Enphase IQ Combiner Box 5, (1) Junction Box, (2) ac disconnects, (1) Meter can with utility meter, 8.100 KW PV ARRAY

14413 JAYSTONE DR, Silver Spring
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.Installation of 39 module 17.160 KW roof mount solar system.

4109 DANA CT, Kensington
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.

8780 BROOKVILLE RD, Silver Spring
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.Installation of 41 roof mounted solar panels and an energy storage system

15761 SENECA RUN CT, Germantown
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.replace defective solar inverter

13216 TRUMPET PL, Silver Spring
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.Add hardwired circuit for EV charger.

5209 RAYLAND DR, Bethesda
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.RE INTRODUCTION OF POWER REQUIRED BY THE POWER COMPANY. No work was done in the unit

20318 WATERS ROW TER, Germantown
Oct 16

Please do not request inspections under this permit until 2 business days after permit issuance.Heavy up 200 amp. Install new 1 toilet & 1 nail exh. fan, 1 washer, 1 dryer, 2 switches, 5 Recep., 2 ped. chairs, 10 ltg. fixtures, 2 emg. lights, 2 exterior lights, 1 exit sign and 1.5-ton AHU & HP.

13710 PARKLAND DR, Rockville
Oct 16