Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required** SEE ADDENDA FOR FIRE SPRINKLERS: MST25-15057
Renovation of HVAC equipment within an existing 25,217 SF type VB building with A-3 and B occupancy. Results in CoC.
Stem wall repair per engineered plans. Special Inspection required for Concrete Construction.
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required**
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required** SEE ADDENDA FOR FIRE SPRINKLERS: MST25-15057
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required**
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required** SEE ADDENDA FOR FIRE SPRINKLERS: MST25-15057
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required** SEE ADDENDA FOR FIRE SPRINKLERS: MST25-15057
This project consists of a 353-unit multi-family development comprising of (1) 4-story and (6) 2 story carriage houses. BLDG 1: New 4-story, type V-A construction, 406,857 SF, group R-2 occupancy, 341-unit Multifamily building with 2hr fire rated wall to separate building into (5) separate areas. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints, Mastic and Intumescent Fire-resistant coatings and elect equip 1000amps. Special Inspections Requ
Renovate existing 7,165 SF facility with type V-B construction, group B occupancy. Occupant load 55. Work consists of new electrical, mechanical, plumbing, and partition walls. Special Inspections for steel construction, masonry construction, and medical gases system. New screened generator. Deferred fire sprinklers and fire alarm. Results in CoO.
Install fire sprinkler monitoring system consisting of (1) addressable fire alarm control panel with (2) 12V backup batteries, (1) photoelectric smoke detector, (1) manual pull station, (1) heat detector, (6) ceiling-mounted horn/strobes, (1) ceiling-mounted strobe, and (1) tamp switch and water-flow switch.
INSTALLATION OF 15-FT X 35-FT 2025 CAVCO PARK MODEL, SERIAL NUMBER CFPUS2547T1211438. ABOVE GROUND SET WITH A/C AT REAR. NO GAS, NO LP TANKS. 10-FT X 18-FT ATTACHED AWNING ICCESR1398. NO ACCESSORY STRUCTURES AT THIS TIME. MININIMUM ONE 9-FT X 18-FT UNOBSTRUCTED PAVED, 2-IN ASPHALT OR 4-IN CONCRETE, PARKING SPACE REQUIRED BEHIND FRONT SETBACK. 34-FT X 43-FT INTERIOR LOT. MINIMUM SETBACKS ARE 5-FT FRONT, 6-FT SEPARATION BETWEEN STRUCTURES IN THE REAR OF INTERIOR SPACES AND A MINIMUM OF 3-FT BETW
Two story townhouses with 2 car garages organized in groups of 4. Each house gets its own permit. New electrical service. See PMT22-09292 for the site work. See PMT23-12717 for individual water meters for each house.**fire sprinklers required**
Residential Remodel – Remodel 858 SF of existing carport and storage to livable space - enclose existing carport to create flex room under existing roof framing - saw cut existing footings and pour new mono footing - install new waste line to tie into existing - install new upsized 400 amp service panel. Reference permit PMT25 16391 for detached garage. Type V construction. R5 occupancy. No deferred items. Special inspections required for epoxy rebar into existing foundation.
Fire Alarm Modification for Elevator 5 and 6 upgrade. Elevator 5 and 6 will be upgraded with shunt. Smoke detectors are existing with no changes. Relays will be upgraded and shunt relay added as new. Heat detectors will be new. Results in a CoC.
Building 5 fire alarm modification, move 2 horn/strobes from wall to ceiling, replace a total of 12 Horn/Strobes with updated LED technology. Approved with Stipulation.
Demo identified partition walls, doors, door frames, plumbing fixtures, lighting, ceiling, and handrails. New partition walls. Infill doorway on north side of room. New lighting, mechanical VAV, and ducts at new lounge room. New architectural and MEP. Deferred fire sprinklers and fire alarm. Results in CoC.
Demo existing lighting and replace with new interior room of an existing gym. New wall switch. New electrical. Results in CoC.
NEW 2757 SF TWO STORY RESIDENCE WITH A 2+ CAR GARAGE AT HAWES CROSSING. INCLUDES OPTIONS FOR GUEST SUITES AND EXPANDED LAUNDRY ROOMS. INCLUDES WATER, ELECTRIC AND GAS METERS. SPECIAL INSPECTIONS FOR POST TENSIONS SLABS. SEE MST23-15248 FOR PARCEL A, B, D AND E AT HAWES CROSSING. ADDENDA MST25-01485 - SHEET E1.1 ADDED CO DETECTOR AT LOFT: SHEET A1.3 REVISED DOORS AT MULTI GEN SUITE: SHEETS E.1 & E1.2 REVISED SD/CO LOCATION AT 1ST FLOOR HALLWAY: SHEET S2.03 · OPT. MULTI-GEN SUITE ILO GARAGE STOR
This project consists of a 353-unit multi-family development comprising of (1) 4-story and (6) 2 story carriage houses. BLDG 3: New 2-story, type V-B construction, 5,001 SF, group R-2 and U occupancy, 2 unit apartment house over parking garage. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints, Mastic and Intumescent Fire-resistant coatings and elect equip 1000amps. Special Inspections Required Emergency Responder Radio Coverage IFC 510. Defe
Interior plumbing repair involving removal and replacement of existing drain, waste, and vent - DWV - piping serving kitchen and two bathrooms. Work included under-slab access for repair of failed sewer lines, installation of new ABS piping and fittings and cleanouts as required. System reconnected to existing building drain. Work performed due to emergency failure. Inspection requested prior to final slab patch
INSTALLATION OF TWO 120 GAL PROPANE TANKS SURFACE MOUNTED TO WALL. 120-FT OF 3/4-IN GALVANIZED GASLINE BURIED 18-IN WITH 14 GAUGE TRACER WIRE FROM TANKS TO 400K BTU POOL HEATER. GASLINE TO BE INSTALLED PER 2024 IFGC & FPD 6104.1.
New 2166 SF single story residence with a 2+ car garage at Hawes Crossing. New water, gas and electric meters. Special inspection for post tension slabs **SEE ADDENDA MST25-07603**
TAYLOR MORRISON #4016 - NEW 1843 SF TWO STORY RESIDENCE WITH A 2 CAR GARAGE FOR HAWES CROSSING 6 . THE DESIGN HAS 3 ELEVATION OPTIONS WITH SLIGHTLY DIFFERENT AREAS. INCLUDES WATER, ELECTRIC AND GAS METERS. SPECIAL INSPECTIONS FOR POST TENSION SLABS, SEE MST23-15585 FOR PARCEL A, B AND D OF HAWES CROSSING. MST24-18584 ADDENDA - HAWES CROSSING PARCEL H - ADD PARCEL H STRUCTURAL INFORMATION. REFERENCE MST22-20982 & MST23-15585.
This project consists of a 353-unit multi-family development comprising of (1) 4-story and (6) 2 story carriage houses. Medina Station, Carriage House - New Build BLDG 7 BLDG 7: New 2-story, type V-B construction, 5,472 SF, group R-2 and U occupancy, 2 unit apartment house over parking garage. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints, Mastic and Intumescent Fire-resistant coatings and elect equip 1000amps. Special Inspections Require
Converting shower to shower, replacing pan, drain, and valves.
This project consists of a 353-unit multi-family development comprising of (1) 4-story and (6) 2 story carriage houses. BLDG 4: New 2-story, type V-B construction, 5,001 SF, group R-2 and U occupancy, 2 unit apartment house over parking garage. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints, Mastic and Intumescent Fire-resistant coatings and elect equip 1000amps. Special Inspections Required Emergency Responder Radio Coverage IFC 510. Defe
Residential primary bathroom remodel: Tub-to-shower conversion. Side by side demo to make the tub area the new shower and the old shower area to be capped off and framed to become a closed linen closet at existing SFR. No change to overall square footage.
PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE