building

906 South Lanore Drive, Illinois-Edp
Mar 31

The purpose of this project is to obtain a building permit for shell improvements. This scope of work includes demolition, new electrical, new plumbing, and minor architectural work including some new interior party and exterior wall work. No structural work. Existing RTUs are being removed. Existing curbs shall remain. Existing interior roof drainage system to remain. Includes a new 1200A electric service replacement and a new 1-inch domestic water meter. Results in CoC.

206 W MAIN ST, Mesa
Mar 31

Building #1. New 2-story, type V-B construction, 45,610 SF, group B occupancy office building for American Leadership Academy Charter Schools. This new design will replace the previously permitted but unbuilt PMT23-16875. Special Inspections Req IFC 510 EMERGENCY RESPONDER RADIO COVERAGE. DEFERRED ELEVATOR: DEFERRED FIRE ALARM. DEFERRED FIRE SPRINKLERS. CO2 LEAK DETECTION AND ALARM. Results in CoO. New (2) 2-inch domestic water service and meter. New 3/4-inch landscape water service and meter.

7733 E PECOS RD, Mesa
Mar 31

Convert the existing 375 SQ. FT. carport to habitable space, construct a 178 SQ. FT. addition to the existing SFR, and construct a new 211 SQ. FT. carport. Truss calculations deferred. The carport conversion and addition will be a new master bedroom, bath, powder bath and laundry area.

1309 W PEPPER PL, Mesa
Mar 31

PERMIT IS ONLY FOR INSTALLATION OF TWO TESLA POWERWALL3 BATTERIES. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

1652 E LAUREL CIR, Mesa
Mar 31

Connect to city sewer after septic abandonment at existing SFR.

6414 E ASPEN AVE, Mesa
Mar 31

CONSTRUCT 109 SF OPEN DECK AT FRONT OF THE EXISTING DECK. NO ELECTRIC, NO PLUMBING. TO BE CONSTRUCTED WITH ALL METAL FRAME AND WOOD CONSTRUCTION. REF. BLD2005-10232 FOR EXISTING 2005 CHARIOT PARK MODEL. REF. BLD2005-09755 FOR EXISTING AZ ROOM AND DECK. MINIMUM ONE 9-FT X 18-FT UNOBSTRUCTED PAVED PARKING SPACE BEHIND FRONT SETBACK REQUIRED TO BE ON 2- IN MINIMUM ASPHALT OR 4-IN CONCRETE. INTERIOR LOT. MINIMUM SETBACKS ARE 4-FT FRONT, 5-FT REAR, 0-FT PARK MODEL SIDE AND 3-FT AWNING SIDE. APPROVED

5001 E MAIN ST 910, Mesa
Mar 31

New 2309 SF single story residence with a 2+ car garage at Hawes Crossing. Includes water, electric and gas meter. Special inspections for post tension slabs **SEE ADDENDA MST25-07605**

3941 S PEONIE, Mesa
Mar 31

SES upgrade from 200A to 400A single phase electrical meter. Two new 200A single phase "interior" electrical panels, one for existing current loads and the other is for future use. No new electrical loads on this permit. Results in CoC.

3032 E MAIN ST, Mesa
Mar 31

Tenant improvement for type II-B construction, Group B occupancy with 22,776 SF and an occupant load of 325. Work includes demo of interior partition walls and construction of new partition walls in vacant space for additional offices and conference rooms. New lighting and outlets in expanded areas. New ceiling mounted mechanical 3-ton air handler unit. Existing restrooms and egress stairs remain unchanged. Deferred fire sprinklers and fire alarms. Approved as noted. Results in CoO.

5416 E BASELINE RD 210, Mesa
Mar 31

Building 1, new 8,335 SF building, type V-B construction. Retail shell space. Scope includes shell buildings only Civil under PMT25-14368. New (1) 2-inch domestic water meter at building 2 only and (1) electric meter on building 1 only. Deferred fire sprinklers, truss calculations. Over-the-Counter Fire Sprinkler Monitoring Permit Required. Special inspections for concrete, masonry, steel, post installed anchors, soils, and electrical. Results in CoC.

9038 E AVIATION WAY, Mesa
Mar 31

Desert uplands envelope lot-patio covers and media wall. All work related to the attached and detached patio covers and media wall to be within the temporary fence. No new disturbance with this permit. The temporary fence is required to remain in place at all times during construction. All areas out of the approved disturbance area shall remain undisturbed at all times. Temporary construction access shall be revegetated as noted on plans. Separate zoning inspection required prior to final build

2215 N WOODRUFF, Mesa
Mar 31

TI to existing type V-B 2,179 SF restaurant space. Work to include interior partitions, MEP's, lighting, kitchen equipment, hood, and finishes. Deferred fire sprinklers, hood fire suppression, CO2 monitoring system, and refrigerant leak detection. Fire alarm under separate related submittal. Special inspection for hood wrap for grease duct. Results in CoO.

2015 S ALMA SCHOOL RD 102, Mesa
Mar 31

Construction, repair, remodeling, demolition, and excavation work activities may be conducted between 6:00 a.m. through 8:00 p.m. Monday through Friday. Construction work outside of the permitted timeframes will require an afterhours permit. Afterhours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide the following information: a. Location of work - 5818 E. McDowell Rd. Mesa, AZ 85215 b. Schedule of hours and days

5818 E MCDOWELL RD, Mesa
Mar 31

Converting tub to shower, replacing pan, drain, and valves.

5402 E MCKELLIPS RD 282, Mesa
Mar 31

PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY AND TWO POWERWALL 3 EXPANSION UNITS. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT I

3633 S PAYTON, Mesa
Mar 31

APN: 220-01-021 CITY SERVICES OUTSIDE CITY LIMITS (WATER)

9310 E MCLELLAN RD, Mesa
Mar 31

PERMIT IS ONLY FOR INSTALLATION OF TWO TESLA POWERWALL3 BATTERIES AND MPU 225AMPS. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY T

11507 E ADOBE RD, Mesa
Mar 31

Remove and replace existing electrical equipment with new at cell tower site. Results in CoC.

2450 S ELLSWORTH RD, Mesa
Mar 31

The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 3/31/2026 ADDRESS: 6363 E VIRGINIA ST MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit

6363 E VIRGINIA ST, Mesa
Mar 31

PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES AN

2214 E GARNET AVE, Mesa
Mar 31

New 3690 SF livable and 1329 SF non livable. Scope includes the main residence and two ADU casitas, main covered porch and garage, attached casita garage, covered porch and patio, and detached two story casita with covered porch. Type V construction. R5 occupancy. Deferred truss calculations. Special inspections required for post tensioning cables, post installed concrete anchors, and soils. Existing 3/4" water meter. New 400 amp electrical panel.

6657 E RUSTIC DR, Mesa
Mar 31

Fabricate and installation of one non illuminated wall sign 18 sq ft LOGO NORTHSTAR PRESCHOOLS.

4824 E BASELINE RD 105, Mesa
Mar 31

Building 2, new 8,040 SF building, type V-B construction. Retail shell space. Scope includes shell buildings only Civil under PMT25-14368. New (1) 2-inch domestic water meter at building 2 only and (1) electric meter on building 1 only. Deferred fire sprinklers, truss calculations. Over-the-Counter Fire Sprinkler Monitoring Permit Required. Special inspections for concrete, masonry, steel, post installed anchors, soils, and electrical. Results in CoC.

9038 E AVIATION WAY, Mesa
Mar 31

Installation of Helical and Push Piers

908 E HAMPTON AVE, Mesa
Mar 31

Install one LED illuminated set of pan channel letters and tagline on a backer panel on front elevation of suite. CONTACT PHYSICAL THERAPY 32 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.

1042 N HIGLEY RD 107, Mesa
Mar 31

Adding 233 S.F. office room to north side of existing primary residential address. Adding 112 S.F. porch to west side of existing SFR. Carport on south elevation to be removed prior to building final.

3017 S SALIDA DEL SOL CIR, Mesa
Mar 31

Install 2 new interior electrical panels and automated welding equipment at existing suite. New electrical equipment. Results in CoC.

1907 S HOBSON 109, Mesa
Mar 31

Please do not request inspections under this permit until 2 business days after permit issuance.Install a new road side speed camera for the Automated Traffic Enforcement Unit (ATEU)Montgomery County of Montgomery County Police Department. The pole is the be placed at 4600 Randolph Rd WW

Unknown, Montgomery County
Mar 31

building

1635 Third St, #1, New Orleans
Mar 31