CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 28-FT X 52-FT ABOVE GROUND 2026 CHAMPION SERIAL NO. 157-00P-H-A006914A/B WITH A/C AT REAR. NO GAS. UPGRADE ELECTRIC PEDESTAL FROM 100AMPS TO 200AMPS. ONE DETACHED 18 FT X 20 FT AWNING ICCESR 4436. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN TWO 9 FT X 18 FT PAVED 2-IN ASPHALT OR 4-IN CONCRETE UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK ONE PARKING SPACE REQUIRED TO BE COVERED. 40-FT X 85-FT INTERIOR LOT. MIN SET
CONSTRUCT A 362 SF SWIMMING POOL SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS". EFFEC
SHEA HOMES #5014 - NEW 2770 SF SINGLE STORY RESIDENCE WITH A 2+ CAR GARAGE AT AVALON CROSSING. INCLUES MANY ELEVATION OPTIONS. NEW WATER, ELECTRIC AND GAS METERS. Addenda per MST25-12444. Revised and added sheets for foundation slab depth for phase 2 foundations. SPECIAL INSPECTION FOR POST TENSION SLABS.
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 24-FT X 60-FT 1979 ABOVEGROUND PARAM MH SET, SERIAL NO. PD1928A, WITH A/C AT REAR. NO GAS. ONE ATTACHED AWNING PER ICC NO. 1398 AWNING ENGINEERING PROVIDED BY CARL PUTNAM NO. 39702, EXPIRES 9/30/27. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM OF TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK AND REQUIRED TO BE ON 2-IN ASP
Grading, Drainage with Sewer and water. All onsite paving and curbing for the project. Install all off-site improvements and street frontage landscaping during the first phase of construction per ZON25-00942. Site is using City of Tempe water and sewer for services. No Elec or Gas under this permit. Approved as noted.
Demolish existing fiberglass tub/shower combo: install 60-inch × 42-inch low-profile preformed shower base, three Durabath Ivory Marble Smooth shower wall panels to below window, 1/4-inch rain-glass chrome-framed enclosure, new Moen shower valve and hand-shower, two grab bars (24-inch and 18-inch), folding teak seat, and two corner shelves. No structural change. No change to overall square footage.
Voluntary Push Pier & Helical Pile installation to prevent further settlement of the structure. Installations are sub-grade & don't affect the exterior appearance of the structure.
New SFR – 1700 SF livable and 1151 SF non livable consisting of 637 SF garage and 510 SF covered patio and 4 SF covered entry. Existing 3/4 inch water meter to remain. New 200 amp electrical panel. Type V construction. R5 occupancy. Deferred Truss Calculations. No special inspections.
This is a CIP project. The City of Mesa has identified necessary water main replacements and/or abandonments at several locations throughout the City. Location 1 was completed through a separate contract. Location 2 – 82nd Place Boise Street to Billings Street Location 3 – 9th Street (Country Club Drive to Robson) and Robson (9th Street to 7th Street) Location 4 – Macdonald (3rd Place to University Drive) and 3rd Place (Macdonald to Center Street) o Install approximately 1,500 feet of 2-inch
Existing 2 Carport to be Converted to livable space and new rear attached patio to be constructed
CONSTRUCT A 1111 SF SWIMMING POOL & 64 SF SPA WITH NATURAL GAS HEAT AND A POOL SLIDE. INSTALLATION OF 162-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 56-FT OF1-IN PE GAS LINE TO 90K BTU BBQ. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTU
New 2406 SF single story residence with a 2 car garage at AVALON CROSSING. Includes a new water, electric and gas meter. Includes an option of a tandem garage
Installation of 200 Amp electric service - no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit
Scope of work: Install one dedicated 20amp circuit from existing electrical panel to bathroom for new gfi recep.(using 12/2 romex). Remove existing bathtub and install new walk-in tub. Use existing drain and plumbing.
Installation of 200 Amp electric service - no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
Construct a 428-sf swimming pool, no spa/no gas. All electrical to comply with 2017 NEC requirements. This permit does not include any accessory structures. Registered structural professional engineer: Jesse Light #58912, expires 12/31/26. Engineering and structural calculations are required to be onsite for all inspections and options highlighted. These plans must conform to the requirements of the 2018 international swimming pool & spa code with all City of Mesa Amendments. Effective January
Please do not request inspections under this permit until 2 business days after permit issuance.Metered Pedestal for Traffic Signal
Please do not request inspections under this permit until 2 business days after permit issuance.Please do not request inspections under this permit until 2 business days after permit issuance.Please do not request inspections under this permit until 2 business days after permit issuance.Please do not request inspections under this permit until 2 business days after permit issuance.New Service pole located at Approx. 19920 Jerusalem Road, Poolesville MD, location is at the intersection of Jerusal
building
building
building
building
building
building
building
building
building
building
building