1. REPLACE SERVICE CASES W/ SELF-SERVICE CASES. 2. REPLACE STAINLESS STEEL TABLES IN SEAFOOD & DELI. 3. REPLACE 2-COMP SINK IN SEAFOOD W/ 3-COMP. SUSHI PREP SINK 4. ADD SUSHI MAKELINE PREP TABLE 5. REPLACE HOT CASE & BASE IN DELI 6. PATCH RESINOUS FLOORING IN FRYER AREA
System modification, remove existing nozzle over griddle and replace with nozzle for a new range. Results in CofC.
This is in city of Mesa Right of Way need Green Tag PMT. Have received UTL permit from engineering . UTL26-00442. Verizon Small Wireless Facility.
COD26-01721 - Client received: STOP WORK Address: 256 E Broadway ? Unauthorized Construction, Section 4-1-4(A) ? Unauthorized Use/Occupancy, 4-1-6(A) Call Sergio O. at 480-644-6467 with questions. “It is a criminal misdemeanor to occupy this building, structure or to remove or deface this notice.” Architect is endeavoring to keep as much of the unpermitted construction as possible. Accessible restroom added, water fountain, mop sink, new cooler. Structure was analyzed and strengthened by struct
Renovation to enclose covered patio into new reception area
New service/maintenance building at an existing RV dealership lot.
Modify existing fire sprinkler system by adding (25) QR pendent 155° 5.6-K 1/2-inch DO fire sprinklers for tenant improvement. Ref: PMT26-15014.
Certificate of Occupancy
Install (2) new shade structures (1,385 SF total) at playground area of an existing City of Mesa park. Electrical power to shade structure lighting under site improvement permit (PMT26-06117). Playground equipment installed under PMT26-16443. Results in CofC.
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment.
Electrical - Resecure Electrical Panel Resecure electrical service panel to wall and reenergize. No new equipment.
Construction, repair, remodeling, demolition, and excavation work may be conducted between 4:00 a.m. through 6:00 AM. 2/25, 3/03, 3/12/, 3/19, 3/25. Work outside of this timeframe requires an afterhours permit. Afterhours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide the following information: a. Location of work 7961 E Elliot,. b. Scope of work to be performed concrete pours c. Anticipated noise should be kept to
Install storage racking system into an existing warehouse building. Special inspections required: post-installed anchors. Results in CofC.
Installation of warehouse racking
Commercial Building Permit
New 10,780 SF, construction type V-B shell office and warehouse building for future Group B and S-1 occupancies, with 209 SF canopy. Scope includes the building shell, 4-hour fire separation on property line. MEP's, site improvements, canopy, and enclosed rear storage yard. New 600 AMP electric meter. New water 1.5-inch domestic and 1-inch irrigation meter. Deferred steel joists, fire alarm, fire sprinklers, and vehicular gate access. Special inspections required for soils, concrete, masonry, s
AFP26-00653 THE PROJECT SCOPE INCLUDES THE INSTALLATION OF A COMPACTOR W/ ROLL-OFF BIN IN THE EXISTING TRUCK DOCK OF DSSA / PH. II. EXIST. ELECTRICAL UTILITIES WILL BE MODIFIED (NEW CIRCUIT) FOR THE PROJECT.
Premanufactured storage water tank and fire pump house. Located at the west side of the campus. Work consists of relocating curb, retaining walls, electric, plumbing. Including installation of a diesel engine driven fire pump rated at 2500 gpm at 170 psi. Special inspection required for concrete, masonry, soils, and post installed anchors. Approved with Stipulation: The Fire Pump House shall be provided with a diesel engine exhaust system in accordance with Section 11.5, NFPA 20, 2019 edition.
Train Depot - elevations & building plans for West Main Village. New 364 S.F. shade structure. Special inspections required for drill & epoxy into post-tensioned slab and PT slab tendon stressing.
Install an additional new electrical meter 200A 3 phase (4 of 4 meters) and interior electrical panel at an existing building for a future tenant. Approve as Noted. Results in CofC.
Modifying rooms 108 and 109 in Building 580 to support the installation of new 5 axis core carver and NDT CT scanner.
New 106 SF premanufactured water vending station, including site-built concrete foundation, anchorage, accessibility improvements, water, sewer, electrical, and associated site improvements. Premanufactured building excluded from permit scope. New (1) 3/4 inch domestic water meter and (1) 200 AMP electric meter. Special inspections for concrete and post-installed anchoring. Results in CoC for site work only.
Remodel of maintenance area in existing warehouse building. New partition wall to create accessory assembly conference room. New architectural and MEP. Deferred fire sprinklers, fire alarm, access control. Results in CofC.
Addition of a third generator for temporary power to SES C4. Special inspection required for electrical. Reviewed as noted. Results in CoC.
Installation of Pallet Rack. Special inspection for post-installed anchoring. Results in CoC.
New Walk-In Fuel Station with 8 Stack Fuel Pumps. Fire sprinkler system included in plan set. REF: PMT26-16833 Civil Landscape (status: rev. req. 10/19/2026)
THE PROJECT SCOPE INCLUDES REMOVING THE EXISTING HIGH-PILED STORAGE RACKING LOCATED IN THE PH. I / WAREHOUSE AREA.
Install new glass bi-folding door into exterior wall at an existing church. Special inspections required: post-installed anchors. Results in CofC.
New modular temporary office and 400 AMP electrical panel. Ref: PMT26-13175. Permit is only for exterior sewer, water, and electrical power supply connections. Results in CofC.
dual-phased development that includes a retail component (Phase 1) and a multifamily component (Phase 2) and includes private roadways that run through the development