Search Permits
191,413 results
PERMIT EXPIRES ON 10/20/2026 ERECTION STARTS: 9/8/2026, ERECTION ENDS: 9/24/2026. RIOT FEST 2026- SMALL TENTSTENT- 3 DAY EVENT (9/18-20/2026)ERECT FIFTY (50) STRUCTURES, ONE (1) 10X50 FRAME, FOUR (4) 10X60 FRAME, ONE (1) 10X70 FRAME, ONE (1) 10X100 FRAME, ONE (1) 10X170 FRAME, ONE (1) 10X320 FRAME, ONE (1) 15X30 FRAME, THREE (3) 20X30 FRAME, NINE (9) 20X40 FRAME, ONE (1) 20X40 POLE, FIVE (5) 20X60 FRAME, SEVEN (7) 20X80 FRAME, ONE (1) 20X100 FRAME, ONE (1) 20X120 FRAME, ONE (1) 30X30 FRAME, ONE
REPAIR (26% TO 50%) FOR WOOD EXTERIOR STAIRWAY (QUANTITY: 1, LOCATION: FRONT OF BUILDING). LANDING: 45 SQUARE FEET. LANDING NOT MORE THAN 6 FEET ABOVE GROUND.
SPR - 2019 CBC - PROPOSED 3-STORY (3) DWELLING UNIT FRAME BUILDING WITH REAR METAL STEPS WITH DECKS AT EACH LEVEL, NEW METAL AND WOOD FENCES (OCCUPANCY CLASS R-5, CONSTRUCTION TYPE VA)
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: BASEMENT AND EXTERIOR WALL.
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: MECHANICAL ROOM.
TEMPORARY SCAFFOLDING: QTY: 2, MAX. LENGTH: 60 FT., MAX. HEIGHT: 200 FT. LOCATION: SOUTH ELEVATION. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 5.85 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 8/17/2026. END DATE: 9/16/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
TEMPORARY SCAFFOLDING: QTY: 3, MAX. LENGTH: 130 FT., MAX. HEIGHT: 235 FT. LOCATION: ALL EXTERIOR FACADE ELEVATIONS. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL OTHER. SPECIFIC LOCATION: CONVENIENCE STORE.
SCOPE: ROOF REPLACEMENT. AREA: 4200 SQ. FT. ROOF COVERING: BUILT-UP ROOF. LOCATION: THE ROOF. IL ROOFING CONTRACTOR LICENSE: 104018264.
REINSTATE PERMIT NO 10165300 MUST BEGIN WORK AND OR REQUEST INSPECTION NO LATER THAN ***AUGUST 2027*** ON PERMIT NO 101065300
SPR 2019 CBC. INTERIOR ALTERATIONS AND REPAIRS TO EXISTING TWO STORY BRICK & FAME SFR WITH BASEMENT (VA CONSTRUCTION TYPE AND R-5 OCCUPANCY) INCLUDING ELECTRICAL, HVAC AND PLUMBING. REMOVE REAR WOOD RAMP AND REPLACE WITH NEW FRAME STARS WITH LANDING. ALL WORK AS PER PLANS.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 36 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: 200 AMP SERVICE UPGRADE 2 RESIDENTIAL 1 PBL METER.
SCOPE: ROOF REPLACEMENT. AREA: 1800 SQ. FT. ROOF COVERING: ASPHALT SHINGLES. LOCATION: MAIN HOUSE. IL ROOFING CONTRACTOR LICENSE: 104019663.
PURPOSE: NEW/REPLACEMENT INSTALLATION. WOOD FENCE - 6'-0' ' (HEIGHT) X 59'-0' ' (LENGTH). LOCATION: REPLACING BACK YARD FENCE.
FOR PERMIT 101079338: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
REPAIR (26% TO 50%) FOR WOOD DECK (NON-ROOFTOP) (QUANTITY: 6, LOCATION: REAR OF BUILDING).
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 5 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: KITCHEN.
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101077882. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: ONE MAGLOCK SYSTEM INSTALLATION AT DOOR 9801-1..
DDS 2019 CBC: REVISION TO PERMIT 101053191 FOR FULL BUILDING PERMIT FOR 8 STORY APARTMENT BUILDING WITH 98 DWELLING UNITS AND 20 CAR PARKING SPACES. REVISIONS CONSIST OF UPDATES TO ELECTRICAL SYSTEM, INCLUDING REVISED PANELS, EQUIPMENT, RISER DIAGRAM, LOAD CALCS. CAISSON ONLY PERMIT UNDER 101050276. (OCCUPANCY GROUP R-2; TYPE IB CONSTRUCTION) CONSULTANT REVIEWER: PRIMERA ENGINEERING
SPR 2019 CBC. NEW 2ND FLOOR ADDITION AND INTERIOR RENOVATION TO EXISTING ONE AND HALF STORY BRICK AND FRAME SFR WITH BASEMENT (VA CONSTRUCTION, R-5 OCCUPANCY) INCLUDING ELECTRICAL, HVAC AND PLUMBING. NO CONSTRUCTION WORK TO EXISTING BASEMENT. ALL WORK AS PER PLANS.
NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 15'-0' '.
FOR PERMIT 101079334: REPLACEMENT GENERAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
CONCRETE MASONRY REPAIR / REPLACEMNT: 5SQ. FT., EXCAVATION = NO. LOCATION: SOUTH ELEVATION - DROPS S2 & S3.
SPR 2019 CBRC: INSTALL NEW FURNACE IN EXISTING RESIDENTIAL UNITS AND BASEMENTS - PER MECHANICAL PLANS.EXISTING: RESIDENTIAL- MULTI-UNIT NO CHANGE IN PROPOSED USE OR DWELLING UNIT NUMBER -15 D.U.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 5.4 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
FIRE ALARM: NEW SYSTEM. ASSOCIATED BUILDING PERMIT:101057754. AFFECTS: 52 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: NO. VOICE COMMUNICATION: NO. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: ENTIRE BUILDING.
SPR 2019 CBC: INTERIOR RENOVATION AND PENTHOUSE ALTERATION/EXPANSION TO EXISTING CONDO UNIT (#615) IN EXISTING RESIDENTIAL BUILDING (R-2, TYPE IV). MECHCANICAL, ELECTRICAL, AND PLUMBING ALTERATIONS THROUGHOUT ENTIRE SCOPE. STRUCTURAL ADDITIONS TO SUPPORT PENTHOUSE ALTERATION/EXPANSION AS PER PLANS. **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **
SCOPE: ROOF REPAIR. AREA: 240 SQ. FT. ROOF COVERING: OTHER. LOCATION: ROOFTOP. IL ROOFING CONTRACTOR LICENSE: 104007722.