FOR PERMIT 101079501: REPLACEMENT ELECTRICAL CONTRACTOR. REPLACEMENT GENERAL CONTRACTOR. REPLACEMENT OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 20 CIRCUITS. RECEPTACLE OUTLETS: 2 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: ELECTRICAL SERVICE.
REPLACE HOIST ROPES ON EG PASSENGER ELEVATOR #5, 3000LBS CAPACITY, 21 FLOORS, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVBATOR BUREAU INSPECTION (EV004324).
IN-KIND REPLACEMENT OF EXTERIOR WINDOWS AND DOORS IN EXISTING OPENINGS. REPLACEMENT WINDOWS: 0; REPLACEMENT SKYLIGHTS: 0; REPLACEMENT DOORS: 1. AFFECTS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), LOCATION: BACK DOOR.
SPR 2019 CBC REVISION TO PERMIT #101072868 3315 S HALSTED ST. (2) NEW BIFOLD WINDOW OPENINGS AT 1ST FLOOR PER PLANS. WORK TO ONLY INCLUDE NEW WINDOWS. ZONED B1-2, MIXED OCCUPANCY A-2 - RESTAURANT GENERAL / R-3 - DWELLING UNIT ABOVE GROUND FLOOR. III-A 2 STORY BUILDING WITH EXISTING BASEMENT AND (2) EXISTING PARKING SPACES.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 5.4 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
SPR 2019 CBRC -REVISION TO PERMIT 101068121 PROPOSED ROOF FRAMING TO BE RAISED ABOVE EXISTING ROOF LINE TO CREATE AN ATTIC SPACE TO HOUSE THE NEW GAS FIRE FURNACE. OCCUPANCY USE R5, CONSTRUCTION TYPE 3B
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 5/1/2026. END DATE: 5/31/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 99 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: 2 CHIMNEYS SIDE AND MIDDLE.
FOR PERMIT 101077131: REPLACEMENT GENERAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
ILLUMINATED FLAT WALL SIGN; 13 SQ/FT; SINGLE SIDED; EAST ELEVATION MOST SOUTH; USING ALL EXISTING COMPONENTS THUS NO ADDITIONAL DRILL HOLES TO THE FACADE.
FOR PERMIT 101081881: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
SCOPE: NONSTRUCTURAL INTERIOR ALTERATION TO EXISTING UNIT, INCLUDES PLUMBING AND ELECTRICAL RECONFIGURATIONS TO KITCHEN AND BATH SUITE, MODIFICATION TO KITCHEN FLOOR PLAN AND OPENING, REPLACEMENT OF PARTITIONS, TRIM AND DOORS.LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), UNIT 5302.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 2500 SQ. FT., LINTEL QTY. 60, MAX. LENGTH 6. PARAPET REBUILDING: 300 SQ. FT. LOCATION: MASONRY REPAIR WORK FOR REMOVE VIOLATION.
TEMPORARY SCAFFOLDING: QTY: 1, MAX. LENGTH: 30 FT., MAX. HEIGHT: 40 FT. LOCATION: EXTERIOR FACADE. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE
NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.
NON-ILLUMINATED PROJECTING BANNER; 11 SQ/FT; DOUBLE SIDED; EAST ELEVATION MOST SOUTH; N/S FACING TEXT; USING ALL EXISTING COMPONENTS THUS NO ADDITIONAL DRILL HOLES TO THE FACADE.
SELF CERT 2019 CBRC: MINOR INTERIOR ALTERATIONS TO SUITE 4010. WORK TO INCLUDE DEMO, NEW PARTITIONS, ELECTRICAL, AND MECHANICAL AS PER PLANS. B-BUSINESS. 1A CONSTRUCTION
INSTALLATION OF SEVEN(7) 4500PASS/HR, 100FPM, PASSENGER ESCALATORS, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.
INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 3.28 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF DETACHED STRUCTURE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
ILLUMINATED FLAT WALL SIGN; 17 SQ/FT; SINGLE SIDED; EAST ELEVATION MOST NORTH; USING ALL EXISTING COMPONENTS THUS NO ADDITIONAL DRILL HOLES TO THE FACADE.
INSTALLING 40 FT ILLUMINATED GROUND SIGN WITN EMC; S/W LOT LOCATION; N/S FACING TEXT. PLAMONDON
PROPOSED 2 STORY TYPE VA CONSTRUCTION SINGLE FAMILY RESIDENCE W/BASEMENT, REAR PATIO,6' FRONT IRON/6' SIDE WOOD FENCES, AND 2 CAR GARAGE W/ROOF DECK AND ACCESS STAIR, PER PLANS.
SPR 2019 CBC. ELECTRICAL WORK ONLY. EXISTING FOUR STORY - 49 DU MASONRY BUILDING. REPLACE EXISTING ELECTRICAL SERVICE WITH NEW. NO ARCHITECTURAL/PLUMBING CHANGES TO EXISTING FLOOR PLANS AT 4025 - 4041 N KEDVALE, CHICAGO IL, AS PER PLANS.
REPLACEMENT OF HOIST CABLES ON ONE(1) 4000LB CAPACITY, 30-FLOOR, 1000FPM, PASSENGER ELEVATOR(#15), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV007178)
TARGET: INTERNALLY ILLUMINATED FACE-LIT WALL SIGN (W VAN BUREN ST ELEVATION) - 16'-3" H X 12'-0" W (195 SQ FT)
TARGET: INTERNALLY ILLUMINATED FACE LIT BULL EYE LOGO PROJECTING SIGN (W VAN BUREN ST ELEVATION) - 8'-0" H X 8'-10" PROJECTION (71 SQ FT)
SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO AMENITY LOUNGE INCLUDING THE REMOVAL OF BUILT IN SEATING AND THE INSTALLATION OF TWO NEW PRE-FABRICATED PHONE PODS. PODS TO HAVE NEW SPRINKLERS AND CONNECTIONS TO SUPPLY AND RETURN AIR THROUGH EXISTING HVAC SYSTEM. NEW LIGHT FIXTURES AND FINISHES. (CONST TYPE 1B, OCCUPANCY A2, F, H3)
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 3 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: SPIRIT AIRLINES TICKET COUNTER.
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS AND ADDITION. CHANGE FROM 4 UNIT APARTMENT BUILDING (OCC. GRP. R-2) TO 3 UNIT BUILDING. (OCC. GRP. R-5; CONST. TYPE VA)