SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO REFRESH EXISTING COMMON CORRIDORS AND TOILET ROOMS ON THE 12TH FLOOR OF AN EXISTING HIGH RISE OFFICE BUILDING. SCOPE INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING. CONSTRUCTION TYPE IA. NO CHANGE IN USE.
MODERDNIZATION TO INCLUDE REPLACEMENT OF CYLINDERS FOR TWO(2) 2000LB CAPACITY, 5-FLOOR, 100FPM, PASSENGER ELEVATORS, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV005321)
FRIST FINANCIAL BANK: INTERNALLY ILLUMINATED FACE LIT PROJECTING SIGN W/DYMANIC DISPLAY (E 55TH ST ELEVATION) - 9'-0" H X 5'-3" PROJECTION (47 SQ FT); REPLACES DOB # 101056045 ISSUED 08/08/2024
FULL REBUILD (SAME AS EXISTING) FOR WOOD PORCH (OPEN) (QUANTITY: 1, LOCATION: REAR OF BUILDING).
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 13 KW. ARRAY OUTPUT: 15.58 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 40 CIRCUITS. RECEPTACLE OUTLETS: 5 . LIGHTING OUTLETS: 3. SPECIFIC LOCATION: BASEMENT..
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 400 AMP SERVICE DISCONNECTING MEANS WITH 40 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT.
INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 2.7 KW. INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF DETACHED STRUCTURE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 3000 SQ. FT., LINTEL QTY. 50, MAX. LENGTH 4. LOCATION: EXTERIOR WALL LINTELS.
SCOPE: ROOF REPLACEMENT. AREA: 1200 SQ. FT. ROOF COVERING: BUILT-UP ROOF. LOCATION: ROOF REPLACEMENT. IL ROOFING CONTRACTOR LICENSE: 104.01821.
SPR 2019 CBRC: INSTALLATION OF NEW 35.75KW SOLAR PV SYSTEM AND ASSOCIATED ELECTRICAL WORK ON 2-STORY EXISTING CHURCH, AS PER PLANS (OCCUPANCY GROUP A-3; TYPE 3A CONSTRUCTION)
ALTERATION OF EXISTING COMMUNICATION EQUIPMENT. ALTERATION OF 2 BOXES AND EQUIPMENT ON 1 TOWERS / STRUCTURES. LOCATION: MODIFICATION EXISTING MONOPOLE ANTENNAS PER PLANS.
DREAM CLEAN CAR WASH: INTERNALLY ILLUMINATED DOUBLE SIDED GROUND SIGN (S PULASKI RD) - 7'-0" H X 10'-8" W (75 SQ FT); 12'-0" OAH
SCOPE: NONSTRUCTURAL INTERIOR WORK ONLY: REPAIR INTERIOR STAIRS PER BUILDING VIOLATIONS DATED 4-1-2025. LOCATIONS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS, INTERIOR.
ADA BATHROOM MODIFICATIONS. REMOVE TUB AND INSTALL SHOWER WITH ASSOCIATED FIXTURES AND TILE WORK
SELF CERT RES. - 2019 CBC: UNIT 3W: INSTALL FIRE RETARDANT COMPOSITE DECK ON TOP OF EXISTING ROOFTOP PER ATTACHED PLANS. OCCUPANCY TYPE R-2; CONSTRUCTION TYPE: III-A; CZO 17-17-0102-B HOUSEHOLD.
INSTALLATION OF TWO(2) 4000LB CAPACITY, 4-FLOOR, 350FPM, PASSENGER ELEVATORS, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.
FOR PERMIT 101074862: REPLACEMENT GENERAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
REPLACEMENT OF TRAVELING CABLE ON ONE(1) 3500LB CAPACITY, 47-FLOOR, 700FPM, PASSENGER ELEVATOR(#4), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100578283)
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO 6TH FLOOR OFFICE SPACE. WORK TO INCLUDE DEMO, NEW PARTITIONS, CEILINGS, FINISHES, FURNITURE, MECHANICAL, ELECTRICAL, AND PLUMBING, AS PER PLANS. CONSTRUCTION TYPE IA, B-BUSINESS USE.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 5/1/2026. END DATE: 5/31/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
FRIST FINANCIAL BANK: INTERNALLY ILLUMINATED FACE LIT WALL SIGN (E 55TH ST ELEVATION) - 4'-0" H X 21'-0" W (84 SQ FT)
INSTALLATION OF CHANNEL LETTERS ON WALL
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 7.79 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 6 KW. ARRAY OUTPUT: 6.6 KW. LOCATION: ROOFTOP. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0250.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 5.33 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
FACE CHANGE ON POLE SIGN - FACE TO READ O'REILLY AUTO PARTS
REPLACEMENT OF GOVERNOR CABLE ON ONE(1) 2500LB CAPACITY, 29-FLOOR, 450FPM, PASSENGER ELEVATOR(#1), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV005060)
LINE VOLTAGE ELECTRICAL WORK. ADD 0 CIRCUITS TO EXISTING 20 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 12 . LIGHTING OUTLETS: 34. SPECIFIC LOCATION: 5TH FLOOR.
INSTALLATION OF (1) ONE RESIDENTIAL PASSENGER ELEVATOR, 1000LBS CAPACITY @ 40FPM, 4 FLOORS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.