Open kitchen to living room and relocate electrical outlets as required at existing SFR. Reconfigure kitchen per plan, move kitchen sink and dishwasher to island and move range. Fill in sunken living room per plan. No change to square footage.
Construct a 540-sf swimming pool & 64-sf spa with natural gas heat. Installation of 159-ft of 2-in PE gas line buried 18-in deep with 18-gauge tracer wire from gas meter to 400K BTU pool heater, 40-ft of 3/4-in PE gas line to 55K BTU BBQ and 25K BTU Firepit. Homeowner responsible for removal of one of two existing interior gas fireplaces. All gas lines are to be installed per 2018 IFGC & COM gas requirements. COM gas to determine if the meter needs to be upgraded. All electrical to comply with 2
New perimeter lighting installed on the edge of building roof and gas pump canopy roof at existing building. New electrical. Results in CoC.
Installation of 4 card reader access maglocks at 4 doors. Results in CoC.
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES AN
TI of an existing 1,520 SF type V-B construction retail shell space. Scope includes interior walls, MEP's, restaurant equipment, and finished. Deferred fire sprinklers. Results in CoO.
ADU Detached – New 800 SF detached accessory dwelling unit - single story 20 by 40 structure - high ceilings - unconditioned storage attic space. Type V construction. R5 occupancy. Upgrade water meter to 1 inch. Existing 400 amp main panel and new 120 amp subpanel. No deferred items. No special inspections.
Gas line for kitchen stove Roughly 55ft of 3/4 polyethylene pipe for a 60K btu stove per Table G2413.4(7).
PERMIT IS ONLY FOR THE INSTALLATION OF TWO TESLA POWERWALL3 BATTERIES. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE F
Swap out existing 200Amp all in one service for a 400Amp all in one service with 200Amp electrical panel at existing SFR.
NEW 2832 SF 2 STORY RESIDENCE WITH 2 CAR GARAGE AND TANDEM GARAGE OPTIONS AT HAWES CROSSING. NEW WATER, GAS AND ELECTRIC METERS. REQUIRES POST TENSION SLAB SPECIAL INSPECTIONS. ADDENDA MST25-01277 ADD PARCEL F & H.
Install new utility weather head electrical feeders, 200 AMP single phase electrical meter, meter socket, 200 AMP disconnect, and feeders to existing electrical panel. Fire damaged trailer was replaced with like-for-like trailer. Permit only associated with new electrical equipment. Results in CoC.
This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. D
CONSTRUCT A 444 SF SWIMMING POOL NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES AN
CONSTRUCT A 359 SF SWIMMING POOL & NO HEAT WITH AN ABOVE GROUND SPA. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF M
Construct a 351-sf swimming pool. No spa, no gas. All electrical to comply with 2023 NEC requirements. This permit does not include any accessory structures. Registered structural professional engineer: Jesse Light #58912, expires 12/31/26. Engineering and structural calculations are required to be onsite for all inspections and options highlighted. These plans must conform to the requirements of the 2024 international swimming pool & spa code with all City of Mesa Amendments.
Installation of 88-ft of 1-in PE gas line buried 18-in with 14-gauge tracer wire from gas meter to 75K BTU pool firepit, 20-ft of 1-in PE gas line to 50K BTU BBQ. All gas lines are to be installed per 2024 IFGC & COM gas requirements. Contact COM gas engineering at 480-644-2909 to determine if the meter needs to be upgraded.
This permit is to address unauthorized construction associated with an office remodel within the kitchen area. The majority of the work did not require a permit: however, one non-load-bearing wall was relocated approximately one (1) foot, and associated electrical was modified. This portion of the work is the only scope requiring permitting. Plan Review: Plans are not required at this time. Inspections: All inspections are to be conducted by Larry Hill. Please note that if, during inspection, ad
PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF
Install one Set of Illuminated Channel Letters 29 sq ft MYEYEDR. on front elevation of suite. Signs shall be installed per NEC 2017 with UL listed components.
New perimeter lighting installed on the edge of building roof and gas pump canopy roof at existing building. New electrical. Results in CoC.
INSTALLATION OF A 60 AMP DEDICATED CIRCUIT BREAKER FOR A WALL CONNECTOR VEHICLE CHARGER IN THE GARAGE. EXISTING 200 AMP SERVICE METER. ELECTRICAL SHALL BE INSTALLED PER MANUFACTURES SPECIFICATIONS AND COMPLY WITH 2024 IBC, 2023 NEC AND SRP STANDARDS.
UNPERMITED Storage room to bedroom conversion.
PERMIT IS ONLY FOR AN UPGRADE TO A 225A SERVICE AND THE INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR S
Construct a single story, 1,563 sqft conditioned space, single family residential dwelling with a driveway. To be constructed per approved plans
New gunite in ground 25-6" x 10'-6" swimming pool and spa with travertine decking.
Install a electric water heater.
Install a electric water heater
Renovation of interior of office space, to meet the needs of a new tenant (Department of Veterans Affairs). Non-structural walls are being reconfigured and extra bathrooms are being added.