CONSTRUCT A 359 SF SWIMMING POOL & NO HEAT WITH AN ABOVE GROUND SPA. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF M
6031 S SANTA RITA, Mesa, AZ
Permit Details
- Permit Number
- PMT26-01159
- Type
- swimming_pool
- Status
- c of c issued
- Issued Date
- May 14, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Rylee Ellsworth
About swimming_pool Permits in AZ
0
swimming_pool permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Clubhouse and fitness room upgrade. Create new openings for more efficient access. Create new storefront entries and openings for windows. Addition of other cosmetic upgrades throughout (Flooring, fixtures, FF&E, etc.). Non fire sprinklered building.
151 E 1ST ST · PMT26-05985
APN: 220-70-378 CITY SERVICES OUTSIDE CITY OF MESA LIMITS (WATER) 522 S 97TH PL, MESA, AZ 85208.
522 S 97TH PL · PMT26-10972
Tenant improvement in existing 270,758 SF, type II-B construction, B, A2, F1, S2 and H3 occupancy facility. Modification include interior installation of new thermal spray operations and relocation of exist equip disturbing approx. 300 SF in a group F-1 area, new roof mounted mechanical equipment and ground mounded dust collector in screen equipment yard north of bldg. Results in CoC.
10036 E GERMANN RD · PMT26-09720
New shell warehouse building 58,150 SF. Type III-B construction. Scope of work includes concrete tilt panel construction and 1-hour rated SES and owners room. New (1) 2-inch domestic water and (1) electric meter. Requirements of 2024 IECC Section C406 were not addressed under this permit and will be required to be addressed as part of the future tenant improvement permit. Special Inspections Required: Emergency Responder Radio Coverage IFC 510, fabricated items, steel construction, concrete cons
8125 E SEBRING AVE · PMT26-08157
Similar swimming_pool Permits
CONSTRUCT A 645 SF SWIMMING POOL & 56 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 65-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER WITH EXISTING RAMADA, SLIDE, AND GROTTO. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGIN
Mesa, AZ · PMT26-14714
CONSTRUCT A 338-SF SWIMMING POOL AND A 49-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 61-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 18-GAUGE TRACER WIRE FROM GAS METER TO TEE, 3-FT FROM TEE TO 65K BTU BBQ STUB, 72-FT OF 2-IN PE GAS LINE FROM TEE TO 400K BTU POOL HEATER. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC AND SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY
Mesa, AZ · PMT26-15877
16x28 Pool w/ SP and electric line for 400K BTU heater
Mesa, AZ · PMT26-15966
CONSTRUCT A 338 SF SWIMMING POOL & 49 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 70-FT OF 2-INPE GAS LINE BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER AND WOOD BURNING FIRE PIT. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGH
Mesa, AZ · PMT26-15903
CONSTRUCT A 760 SQ FT IN- GROUND SWIMMING POOL AND 49 SQ FT SPA. WATER HAZARD ENTRANCE ALARMS TO BE INSTALLED ON ALL DOORS AND WINDOWS THAT GAIN ACCESS TO POOL AREA. INSTALL NEW ELECTRICAL LINE: 140 FT OF 1" SCH 40 CONDUIT, 2) # 6, (2) #8 THWN WIRE FROM MAIN PANEL TO SUB PANEL. A MINIMUM OF 18" GROUND COVER. 60 AMP CIRCUIT BREAKER. ELECTRICAL TO COMPLY WITH 2017 NEC AND SRP SPECIFICATIONS. INSTALL NEW GAS LINE: 150 FT OF 2" PE GAS PIPE, A MINIMUM OF 18" GROUND COVER. FIELD INSPECTOR TO DETERMINE
Mesa, AZ · PMT21-15786
About swimming_pool Permits in Mesa, AZ
What is a swimming_pool permit?
A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.