PermitDig

Search Permits

2,914 results · type: commercial

Development of new 15,058 SF, type V-B construction, group R-2 and S-2 occupancy, 4-bay Fire and Medical Station with 10 Dorms and site construction. Water meters: 1.5-inch domestic and 1-inch landscape. Special inspection req. - steel, concrete, masonry and anchors. Fire sprinkler system and electric vehicle gates are included in this permit plan set. DEFERRED FIRE SPRINKLERS AND ALARM. Results in CoO.

3441 S 80TH ST, Mesa
Sep 30

Donor antenna is installed on the roof and takes signal to the BDA (Bio-Directional Amplifier) from riser. BDA then Amplifies the signal and sends it to the DAS (Distributed Antenna System). All coax cable will be installed in conduit per fire code. System will be monitored with 7 Supervisory signals sent to the Fire Alarm Control Panel from BBU (Battery Back Up) Annunciator Panel.

10437 E ELLIOT RD, Mesa
Sep 30

Four site-built equipment pads, underground telecommunications duct banks, grading, and associated landscape improvements. Prefabricated ME hut structures are not within this scope of work. Temporary mobile generators are not included as permanent site equipment under this permit. Results in CoC.

3841 S ELLSWORTH RD, Mesa
Sep 30

Equipment Platform in assoiciation with PMT26-06512.

5559 S SOSSAMAN RD 109, Mesa
Sep 30

Install electrical 200A SES and meter for construction site power. New 200A panel with (1) 50A breaker for twist lock outlet. Results in CofC.

6147 E MAIN ST, Mesa
Sep 30

Install (4) new steel canopies (1,368 SF total), attached to a new building (PMT25-16974). Results in CofC.

3663 S POWER RD, Mesa
Sep 30

New stand-alone single story building as an accessory building for the church that is in the adjacent building to the east. Contains assembly space, a warming kitchen, storage, and restrooms. The site is a pad. Parking is provided in the existing development. Deferred fire sprinklers and fire alarm.

1718 W BROADWAY RD, Mesa
Sep 30

This project is a code upgrade from previous approval and permitted plans. This package is for the exterior shell only. Interior tenant improvement Plans will be provided under separate submittal. Deferred fire sprinklers and fire alarm.

8830 E GERMANN RD, Mesa
Sep 30

The project is an interior remodel of an exsiting 16,800 sq.ft. building. The new spaces include five classrooms ranging 378-389 square feet. The exterior work includes enhancements to the exterior of the building. Deferred fire alarm.

5047 E ROADRUNNER DR, Mesa
Sep 30

Modify NFPA 13 fire sprinkler system by replacing sprinkler mains with schedule 40 pipe and adding new air vent due to corrosion.

1400 S DOBSON RD, Mesa
Sep 30

Install 2025 NFPA 72 fire alarm system for a 2,400 SF A-2 lunch tent, including a conventional fire alarm control panel, linear heat detection, manual pull stations, and audible/visual notification appliances. Approved as noted.

3255 S 96TH ST, Mesa
Sep 30

Modify Ansul hood fire suppression by adding (2) nozzles, adjusting existing nozzles, and adding (1) detection bracket. Field inspection is required to verify that no modifications to the existing electrical or gas systems were made in conjunction with the appliance additions. Approved as noted. Results in CoC.

1601 W MAIN ST 3, Mesa
Sep 30

Installation of solar photovoltaic energy generation system on fuel island canopy, including trenching to back exterior wall of store for feeder conductors to utility line side interconnection

1733 S GREENFIELD RD, Mesa
Sep 30

Repair broken electrical flex line and missing j-box cover plate per annual fire inspection of property. RV Park

6547 E MAIN ST, Mesa
Sep 30

INSTALL BACKFLOW PREVENTER ON EXISITING WATER LINE. SHALL COMPLY WITH CITY OF MESA ADOPTED ORDINANCES, CODES AND STANDARDS.

1233 S ALMA SCHOOL RD, Mesa
Sep 30

CONSTRUCTION TRAILER & GENERATOR - 5 story building for Cubs baseball team, and 4 story candlewood hotel

2630 W RIO SALADO PKWY, Mesa
Sep 30

Amendment to approved landscape for alternative landscape plan for 40' SRP Easement along North property line

3255 S 96TH ST, Mesa
Sep 30

PROJECT IS TO RELOCATE THE EXISTING FIRST-FLOOR IDF ROOMS AT BANNER BAYWOOD MEDICAL CENTER TOWER 2. IDF ROOMS 0104 AND 0105 WILL BE COMBINED INTO A SINGLE APPROXIMATELY 180 SF IDF ROOM AND RELOCATED TO ROOMS 100363, 100363A, AND A PORTION OF ROOMS OC1-002 AND 100362. IDF ROOM 0107, LOCATED IN THE CENTRAL PLANT/FACILITY SERVICES AREA, WILL BE RELOCATED TO ROOM 100233. THE PROJECT WILL CONSIST OF FINISHES REFRESH.

6750 E BAYWOOD AVE, Mesa
Sep 30

** Big Set** BHSM is seeking to do an approximant 13,000 SF single-story building expansion to add 20-patient rooms and ancillary support spaces to their existing inpatient rehabilitation hospital located in Mesa, AZ. Disciplines included are civil, landscape, structural, architecture, MEPF, and technology. Med gas. Deferred fire sprinklers, fire alarm, access control.

1702 S PIERPONT, Mesa
Sep 29

Occupancy verification for an existing 2,475 SF, type VB construction, B occupancy suite. No change to building occupancy use -change from a Fitness/Nutrition business to Day Program for adults with developmental disabilities. Services include life skills training, socialization skills, creative arts, recreational activities, and community support. Building inspection req to verify existing condition. Approved with comments. Results in CoO.

2111 S ALMA SCHOOL RD 8, Mesa
Sep 29

The improvements of the east side of 106th Place

10625 E AUTO DR, Mesa
Sep 29

DEVELOPMENT FOR NEW SHELL CONSTRUCTION. THE PROPOSED USES ARE APPROVED USE IN PAD ZONING PER CITY OF MESA DEVELOPMENT CODE. WE ARE PROPOSING CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 5,607 S.F. AND OVERHANGS TOTALING 454 S.F. Installation of all off-site improvements and street frontage landscaping during the first phase of construction. Deferred fire sprinklers and fire alarm.

10953 E DESTINATION AUTO DR, Mesa
Sep 29

11031 E Gateway Auto Drive DEVELOPMENT FOR NEW SHELL CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 6,067 S.F. WITH COVERED PATIO 1,200 S.F. AND OVERHANGS TOTALING 562 S.F. Deferred fire sprinklers and fire alarm.

11035 E DESTINATION AUTO DR, Mesa
Sep 29

DEVELOPMENT FOR NEW SHELL CONSTRUCTION. THE PROPOSED USES ARE APPROVED USEIN PAD ZONING PER CITY OF MESA DEVELOPMENT CODE. WE ARE PROPOSING CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 5,500 S.F. WITH COVERED PATIO 2,044 S.F. OVERHANGS TOTALING 544 S.F. AND OPEN PATIO 400 S.F. Deferred fire sprinklers and fire alarm.

11059 E DESTINATION AUTO DR, Mesa
Sep 29

DEVELOPMENT FOR NEW SHELL CONSTRUCTION. THE PROPOSED USES ARE APPROVED USE IN PAD ZONING PER CITY OF MESA DEVELOPMENT CODE. WE ARE PROPOSING CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 6,220 S.F. WITH COVERED PATIO 980.50 S.F., DRIVE THRU CANOPY 246 S.F. AND OVERHANGS TOTALING 433.30 S.F. Deferred fire sprinklers and fire alarm.

10911 E DESTINATION AUTO DR, Mesa
Sep 29

DEVELOPMENT FOR NEW SHELL CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 6,113.5 S.F. WITH DRIVE THRU CANOPY 253 S.F. AND OVERHANGS TOTALING 563.32 S.F. Deferred fire sprinklers and fire alarm.

11103 E DESTINATION AUTO DR, Mesa
Sep 29

DEVELOPMENT FOR NEW SHELL CONSTRUCTION. THE PROPOSED USES ARE APPROVED USE IN PAD ZONING PER CITY OF MESA DEVELOPMENT CODE. WE ARE PROPOSING CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 6,121 S.F. WITH COVERED PATIO 350.50 S.F. DRIVE THRU CANOPY 246 S.F., AND OVERHANGS TOTALING 562.30 S.F. Deferred fire sprinklers and fire alarm.

11125 E DESTINATION AUTO DR, Mesa
Sep 29

Repair damaged stem wall utilizing Glass Fiber Reinforced Polymer Rebar and Structural Repair Mortar. Special inspections required: Concrete construction. Approved as noted. Results in CofC.

719 N CHERRY, Mesa
Sep 29

Install above ground buildings and structures associated with Phase 02. Foundations and underground utilities for Phase 02 have previously been permitted under PMT24-07723. Other exclusions to this permit review include all pre-engineered metal buildings (PEMBs) located on the phase 02 site. These structures will be permitted through the Arizona Department of Housing (ADOH) and provided to the City of Mesa for fire code review as part of that submittal. Deferred fire sprinklers, fire alarms and

7232 E ELLIOT RD, Mesa
Sep 29

GAS SHUTOFF, PRECATION MEASURE DUE TO A FIRE

1940 W UNIVERSITY DR, Mesa
Sep 29