Search Permits
2,827 results · type: commercial
Group U occupancy. New foundation (29,535 SF) and canopy (144 SF). New electrical grounding systems for modular building under this permit. New modular building for data center IT conduit, permitted by AZDOH (Not in Scope of Work For This Permit). Special Inspections required: Soils, steel construction, concrete construction, high strength bolts, and post-installed anchors. Approved as noted. Results in CofC.
Site improvements for proposed hotel and future retail bldg. Onsite-parking, water, meter, drainage infrastructure, landscape, site amenities, screen walls, retaining walls, parking lot lights. Water Meters: (2) 1-inch landscape meter and service. REF: PMT26-16094 for hotel bldg., domestic water meter and elec. Results in CoC.
New Shell building, single story, 4,362 SF, type VB construction as B, M or S2 occupancy. Special inspection req. steel and masonry. Deferred Wood Truss & Calc. Deferred fire sprinklers and fire alarm. Water meters: (1) 1-inch Domestic meter with 1-1/2" service. Shell building, no restroom, unconditioned. Results in CofC.
The project is an interior remodel of an exsiting 16,800 sq.ft. building. The new spaces include five classrooms ranging 378-389 square feet. The exterior work includes enhancements to the exterior of the building. Ref: Code Mod PMT26-19817. Deferred fire alarm.
Install 2025 NFPA 72 fire alarm system consisting of a new Firelite FACP with communicator, (4) manual pull stations, (1) smoke detector, various modules for hood suppression and duct detectors, and (2) a notification appliance circuits supporting (7) horn/strobes, and (8) strobes.
The project consists of the mass grading of the east parcel to conclude development of the project during this current phase along with all required grading & drainage, utility and paving improvements.
COMMUNITY CLUBHOUSE
potholing for design and discovery of utilities
LVC will install new fire alarm devices and use existing wire.
potholing utilities for design and discovery
Replacement of an existing Make Up Air Handling Unit on the existing Paint Booth # 2 with a new gound mounted Make Up Air Handling Unit located outside the building.
Installation of bulk CO2 monitoring system used for beverage dispensers. Results in CofC.
THE PROJECT SCOPE INVOLVES RECONFIGURING EXISTING MODULAR FURNITURE IN BLDG. 1 / ADMIN. EXISTING UTILITIES WILL NOT BE MODIFIED TO ACCOMMODATE THE INSTALLATION.
Fire Sprinkler Monitoring system to be installed
THIS PROJECT IS A CODE UPGRADE FROM PREVIOUS APPROVAL AND PERMITTED PLANS. THIS PACKAGE IS FOR THE EXTERIOR SHELL ONLY. INTERIOR TENANT IMPROVEMENT PLANS WILL BE PROVIDED UNDER SEPARATE SUBMITTAL.
Hang exterior signage and monument panels
Replace existing 400A 4 meter pack like for like for units 122,222, 121,221,
· REMOVE EXISTING 32'-11" TALL LIGHT POLE · INSTALL NEW 34'-4" TALL LIGHT POLE W/FOUNDATION · INSTALL [3] NEW ANTENNAS W_INTEGRATED RADIO · INSTALL [1] NEW METER PANEL ON NEW LIGHT POLE · INSTALL [1] NEW FIBER VAULT
60' STEEL FLAGPOLE INSTALLATION
Commercial Building Permit
Development of new 25,619 SF, type VB construction, group B and S1 occupancy office bldg. Scope to include interior fit out, mechanical, plumbing and electrical. Special inspection req. for Concrete, masonry, steel, post install anchors, soils. Special inspection req. Elec equip rated 1000A. Deferred Wood truss. Water Meter: (1) 1-1/2 inch Domestic meter and 2-inch service. Deferred fire sprinklers and fire alarm. REF: PMT26-10001 for Civil Landscape. Results in CoO.
Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 4/22/2026 ADDRESS: 2859 E CAPRI CIR 1 MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A writ
Proposed improvements include construction of a single-story convenience store of 4,877+ SF with associated drive, gas pump, and vehicular parking.
Installation of temporary portable generators on-site in 30,371 SF area, enclosed with 32ft tall sound walls of construction type V-B, group U occupancy. Temporary generators will be in place for a duration of 3 to 4 months until permanent power is available, utilized for commissioning activities to facilitate an early start-up of all mechanical and electrical systems. Special inspection req. for elect equip rated at or above 1,000amps. REF: PMT24-15709 Development plan. Results in CofC.
NTT Global Data Centers Americas is adding an additional Data Center building in Mesa, Arizona as part of a 244MW master planned site. PH6 will consist of 8 vaults with prefabricated UPS electrical power modules, generators and closed loop air-cooled chillers located on the exterior. The initial buildout will consist of a core and shell, underground utilities and equipment pads, and a single 8 MW vault with 56 MW future vaults 2 through 8. The envelope will consist of tilt up concrete panels wit
Electrical infrastructure upgrade for the Mobile home site park. Approved with stipulation. Results in CofC.
Demolish exiting light pole in ROW. Install new light pole, wireless equipment, and 100A single phase pedestal electrical meter. Approved as noted. Results in CofC.
Construction new building Chipotle restaurant at The Landing at Falcon Field 2,402 SF new construction, civil, architectural, structural.
Install PV system on fuel canopy at existing gas station. PV system exempt from permit, Mesa admin code 4-1-4(B)(2)(r). Building permit for electrical conduit trenching and recertification of SES listing. Approved as noted. Results in CofC.
Install PV system on fuel canopy at existing gas station. PV system exempt from permit, Mesa admin code 4-1-4(B)(2)(r). Building permit for electrical conduit trenching and recertification of SES listing. New electrical equipment shall be painted to match existing building. Results in CofC.