Search Permits
2,827 results · type: commercial
THIS PROJECT CONSISTS OF A NEW ONE-STORY 2,265 SF STEEL RAMADA AND AMENITY BUILDING THAT WILL INCLUDE RESTROOOMS, COVERED GATHERING SPACE, AND POOL EQUIPMENT SERVICE YARD. SCOPES INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND PLUMBING ELEMENTS. THE BUILIDNG IS AN EXPOSED STEEL STRUCTURE WITH STANDING SEAM METAL ROOFING, EXPOSED MASONRY WALLS AND AN OPEN BREEZEWAY THROUGH THE SPACE.
Planning approved placing a 40-foot shipping container for storage at our Light Industrial property and directed me to obtain a building permit. The work is to set the container behind our office/warehouse.
like-for-like partial replacement - replacing ~24 inch section of original 2" polyurethane pipe using new 2" polyurethane pipe joined using couplings. Approved by Larry Snyder.
Construction activities are not restricted in general, but outside noise attributed to construction is limited to the following hours: Regular Hours (October 16 – April 30) · Monday–Friday: 6:00 a.m. to 8:00 p.m. (5:00 a.m. for concrete pouring) Summer Hours (May 1 – October 15) · Monday–Friday: 5:00 a.m. to 7:00 p.m. (4:00 a.m. for concrete pouring) · Saturday: 7:00 a.m. to 7:00 p.m. Work that generates noise outside of these hours requires approval and an after-hours permit. After-hours
Commercial Building Permit
Commercial Building Permit
Two (2) new electrical services, switchgear cabinet, transformer and service entrance stations (SES) for each services with screening. (2) new electric meters. Installation of 8-foot-high masonry walls with gates at the west and east sides of the building to screen the electrical equipment. Special inspection for electrical, concrete, and masonry. Results in CoC.
New Freestanding 8,320 S.F. Office & Aircraft Hangar. Includes an 872 SF mezzanine. Type II-B Construction Type. Groups S-1 & B Occupancies. Includes a new 3/4-inch domestic water meter. This permit includes fire alarm sprinkler monitoring. 409 NFPA Group III Hangar. Special Inspections required for: Steel, Construction and Masonry. Deferred Fire Sprinklers. Results in CofO.
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building C: 1-story, type II-B construction, 3,451 SF, group S-1 occupancy aircraft storage hangers. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for primary permit. REF: PMT24-01453 - Code modif
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building D: 1-story, type II-B construction, 13,692 SF, group S-1 occupancy aircraft storage hangers. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for primary permit. REF: PMT24-01453 - Code modi
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building B: 1-story, type II-B construction, 25,047 SF, group S-1 occupancy aircraft storage hangers and 7,216 SF, group B occupancy offices. Including fire sprinklers and fire alarm (sprinkler monitoring). Special inspection req. - Fabricators, Steel, concrete, masonry, epoxy anchors. Water meters: (1) 1.5-inch domestic. Approved with Stipulation - civil comments. REF: PMT25-07553 for pr
Entire project is a development of (4) 1-stories pre-engineered metal buildings of Aircraft Storage Hangers. Building A: 1-story, type II-B construction, 19,390 SF, group S-1 occupancy. Including fire sprinklers and fire alarm (sprinkler monitoring). The following operations are prohibited within the facility: Fuel transfers, Welding, Torch Cutting, Torch Soldering, Doping, Hot Work (e.g., welding, cutting, brazing, grinding), Spray Painting, Oxygen Service, Composite Repairs, Fuel System or Fue
New additional electrical service of 2,500 AMPS. Exterior electrical only, future TI under separate permit. New 2,500 AMP electrical meter. Special inspection for electrical at or over 1,000 AMPS. Results in CoC.
East yard TI of existing office space, building type IIA, with B occupancy. Modifications of 7,587 SF of non-structural interior walls, MEP's, and restroom reconfiguration. Deferred fire sprinklers and fire alarm. Results in CoC.
Foundation-only permit for a new top-running bridge crane rail system. Scope includes new reinforced concrete footings and associated anchorage. Crane rail support structure and baseplates will be a separate permit. Special inspection for soils, concrete and post-installed anchoring. Reviewed as noted. Results in CoC.
Demolish exiting light pole in ROW. Install new light pole, wireless equipment, and 100A single phase pedestal electrical meter. Approved as noted. Results in CofC.
4 story wood framed hotel with 174 guestrooms, amenities include full restaurant, event lawn and pool area. Deferred fire sprinklers/standpipes, fire alarms, hood suppression, and canopies. Special inspections for emergency response radio communications and fire caulking. 2 - 2" Domestic Water Meters Manifolded, 1 - 1" Landscape Water Meter. 2" Service Line for future building. Meter will not be set with this PMT.
New shared use path along the East side of the Eastern Canal from Broadway Rd to Baseline Rd. New asphalt paved pathway, pedestrian lighting, and crosswalk improvements. New lighting connected to existing electrical power. Results in CofC.
INSTALL BACKFLOW PREVENTER ON EXISITING WATER LINE. SHALL COMPLY WITH CITY OF MESA ADOPTED ORDINANCES, CODES AND STANDARDS.
AFP26-01284 Replacing the main circuit breaker to SES-1 to fix the current conditions of the service entrance.
Applying for building permit to repair and re-energize damaged meter
Permit by Inspection to verify occupancy classification for (F-1) & (B) Occupancy. 5047 s.f. Fabrication Shop. VB Construction. Max 33 occupants. No work under this permit. Inspection required.
Commercial Building Permit
Commercial Building Permit
Place Fiber Vault and Stub in ROW
This permit includes (4) new 2-inch domestic water meters. Results in CoC.
Install new 200 feet of 3/4-in PE gas line for a future bbq grill at new semi-public pool (PMT26-08154) in an existing housing community. New gas line to be installed in a 4-inch PVC gas sleeve. Results in CofC.
Modify existing fire alarm system by adding (6) ceiling-mounted horn/strobes, (1) ceiling-mounted weather-proof horn/strobe, (2) ceiling-mounted strobes, and modules for duct detectors, duct smoke detectors and kitchen hood for tenant improvement. Ref: PMT26-00479.
Install electrical infrastructure and chargers for COM Fleet electric vehicles at EMSC. New 3-phase electric meter.
No work is being done on this property, There were sprinklers put inside the offices and determined that there was never a certificate of occupancy done on this and it was built in 1970's