New development of a 226,665 SF, 289 unit 7-story mix-use building comprising of 5-story type III-B construction apartment units above a 2-story type I-A construction parking garage with commercial space. Special inspections req. - Steel, concrete, wood, masonry, soils. Mastic and intumescent fire-resistant coatings, fire-resistant penetration & joints and Electrical equipment rated at or above 1,000 amps. Special inspection for Emergency Responder Radio Coverage. Deferred fire sprinklers, fire
This permit for fire alarm design is at the request of Tony Curry and the City of Mesa for a tent structure that is being labeled as a permanent structure. Tent permit to reference is FTP-12869. Fire alarm scope includes an FACU, wall/horn strobes as shown / required, and a manual pull station.
Permit Amendment to expand tenant scope into remaining space of the building. Tenant will be occupying the entire building.
New Convenience Store, Fuel Canopy, Trash Enclosure (uncovered), and Underground Storage Tanks as associated with fuel sales. Civil/landscaping Plan review permit # PMT26-07500.
FIRE DIALER - INSTALLATION OF A DEDICATED FUNCTION CONTROL UNIT FOR SPRINKLER WATERFLOW AND SUPERVISORY MONITORING. PERMIT RELATED TO PMT25-12194
Demo exterior building wall at two locations to install new egress doors at existing building. Demo interior non-load bearing partition wall to install new door. New structural, architectural, and electrical. Special Inspection is required for masonry construction. Results in CoC.
3 new fabric shade structures at new apartment complex. Results in CoC.
Development of 1 story Canopy structure for BLDG#13, PEMB structure with perforated metal screen walls, 918 SF, type II-B construction, group U occupancy with approx.131 SF platform. Special inspection req. steel, concrete, masonry, soils, spray fire-resistant, mastic & intumescent fire-resistant coating, Fire-resistant penetration & joints, Fire lanes /roadways. Deferred Fire Alarm and Fire Sprinklers. REF: PMT25-02731 Civil Plans, REF: PMT25-01899 Foundation. Results in a CoC.
The project includes adding security gates and fencing to the main entrance of the Aspenwood mobile home subdivision. The entrance geometry will be revised with these improvements. Signage by separate permit. Deferred electrical vehicle gates. CoC. PMT25-22782A Revising wall construction plans to build wall at an angle to driveway.
Modify existing fire sprinkler system by adding (50) wet QR 155° 5.6-K 1/2 DO fire sprinkler.
Install a fire alarm cellular dialer to an existing fire sprinkler monitoring system.
New 7,024 gray shell building, 2,800 SF patio, and 567 SF canopies (10,391 SF total) for future B, A, and M occupancies. New 1000A 3 phase electrical meter, gas meter, and 1,500 gallon grease interceptor. (5) new mechanical heat pump RTUs. New civil, structural, architectural, MEP, and Fire Protection (fire alarm and fire sprinklers). Deferred submittal: wood trusses. Special inspections required: Electrical performance test, concrete construction, steel construction, fabricated items, post-inst
Demolish exiting light pole in ROW. Install new light pole, wireless equipment, and 100A single phase pedestal electrical meter. New structural and electrical. Special inspections required: steel construction, concrete construction, cast-in-place deep foundations, anchor bolts/post installed anchors. Results in CofC.
Install new equipment and relocate existing equipment in existing facility. Relocate 4 existing car hoist. Install new air compressors, pallet wrap machine, and portal crane. Tie into existing plumbing water supply line for new ice-maker and car rinse. Special inspections required: concrete construction, steel construction, and high-strength bolts. Results in CofC.
Demo of the Fry's 55 fuel center and replace with parking and landscape diamonds. Special inspection for soils. Results in CoC.
Exterior tenant improvement of existing 533,835 SF, type III-B construction shell building, S-1, B, A-3 and H-3 occupancy for package delivery service facility as a product sortation and delivery service. Extent of site exterior bldg work consist of parking lot striping modification, site lighting, new mech and elect equip and pads with screening. Minor sidewalk modifications, and a new concrete sidewalk to connect the new proposed associate parking lot to the entry of the building. Modification
New premanufactured Fiber Splice Enclosure on new foundation at facility under construction (PMT-24-15709). New mechanical and electrical. Special inspection for concrete construction. Group U Occupancy. Type II-B Construction. 115 SF. Approved as noted. Deferred Submittal for Fiber Splice Enclosure Walk-In Cabinet. Results in CoC.
Foundation only permit. Special Inspection req. - steel, concrete, masonry, soils, deep foundations, helical pile foundations. REF: PMT25-02731/PMT24-21242 civil, PMT25-02993 building. Results in CoC.
Modifications to existing ANSUL System for proper coverage of existing tilt skillet in kitchen of an existing indoor amusement building. Adding 1 new 1.5 gallon cylinder, 1 new 3N nozzle over Tilt Skillet. System and hood are all existing. Results in CofC.
Replace the Corroded and leaking fire sprinkler heads in the banner desert parking garage. Approved with Stipulation.
New 875 SF Type V-B canopy and remodel of the existing concession stand. Scope of work includes demolition and replacement of the existing canopy, interior and exterior renovations to the concession kitchen and service area, associated mechanical, electrical, and plumbing (MEP) work, and finishes. Deferred truss calculations. Special inspections required for soils, concrete, and structural steel. Results in CoC.
New development of a 1-story, 8,288 SF, type VB construction, B occupancy Veterinary clinic with 696 SF of canopy. Civil and Landscape included. Special inspection req. - steel, concrete, wood, soils, sprayed fire-resistant materials, EIFS, Elect equip rated 1000A. Deferred Roof trusses, roof screens, roof access ladder and bldg supported canopy/awning. Deferred fire sprinklers. Fire sprinkler monitoring system under a separate related permit. Water meters: (1) 1.5-inch Domestic and (1) 0.75-inc
Civil improvements to existing site entrance at the MSA Data Center, to include driveway widening, additional parking expansion and install of (2) Pre-Engineered Metal Bldgs.: (32 SF) Guard Shack and (393 SF) Trucker Driver Shelter. Scope to include associated site lighting relocation and new elect panel from exist generator. Special inspection req. for soils and concrete. Results in CoC.
Bldg 1 - Expansion and New building to existing campus for worship. Expansion of 5,885 SF of A-3 occupancy worship and lobby to existing type II-B construction, A-3 and B occupancy worship building and addition of (2) single user ADA restroom, enhancement to the existing landscaped courtyards, and expansion of off-street parking per the masterplan. Scope to include associated structural, mechanical, plumbing and electrical. Deferred Pre-fab wood truss, wood i-joist, steel joist/girders. Rec
Bldg 4 - New building development on existing campus of 14,441 SF, type VB construction, A-3 and B occupancy and with 3,741 SF canopy building for religious classrooms and multipurpose assembly space. Building to include (7) classrooms, multipurpose assembly space and restrooms. Scope to include associated structural, mechanical, plumbing and electrical. Deferred Pre-fab wood truss, wood i-joist, steel joist/girders. Record: PMT17-07050 Phase1 Redemption Gateway Church. Deferred fire sprink
Minor Street Repair
New private utility substation. Scope of work includes the foundation, structural, and electrical. Work includes installation of a new prefabricated metal substation equipment enclosure, delivered to the site as a single assembled unit. Special inspections include soils, deep foundations, concrete, structural steel, and electrical. Reviewed as noted. Results in CoC.
TO INSTALL STORM PIPING AND PAVEMENT WITHIN THE ISO YARD ON SOUTHERN PART OF THE PROPERTY
Onsite MASS GRADING Plan only. Full Civil improvements to be submitted under separate permit. Mass grading includes only clearing, grubbing and earthwork. Mass grading shall not include construction or installation of infrastructure, hardscape or any other improvements outside of grading operations.
REMOVE EXISTING 32'-6" LIGHT POLE INSTALL UNDERGROUND POWER & FIBER CONDUITS PER SRP REQUIREMENTS INSTALL 34'-3" LIGHT POLE INSTALL (1) GROUND-MOUNTED ELECTRICAL METER PEDESTAL ON CONCRETE PAD INSTALL (1) CANISTER ANTENNA AND SHROUD INSTALL (3) ERICSSON AIR 1672 ANTENNA INSTALL (2) ERICSSON 4402 RADIOS IN SHROUD