Search Permits
2,827 results · type: commercial
Install (2) new shade structures (2,150 SF total) at playground area of an existing City of Mesa park. Electrical power to shade structure lighting and canopy site plan under site improvement permit (PMT26-05270). Playground equipment installed under PMT26-15029. Results in CofC.
Capital Improvement Project for park upgrades at Sheepherders Park. Install of 64ft x 72ft Post tension slab for the Pickleball upgrades. REF: PMT26-05267 for overall improvements. Results in CoC.
Install (2) new shade structures (2,756 SF total) at playground area of an existing City of Mesa park. Electrical power to shade structure lighting and canopy site plan under site improvement permit (PMT26-05256). Playground equipment installed under PMT26-15041. Results in CofC.
Install new playground equipment. Plans reflect playground manufacturer product cutsheets. Related site work under PMT26-06117. Results in CofC
Replace the existing outdated Service Entrance Section (S.E.S.) with a new code-compliant S.E.S. of equal capacity. The new S.E.S. will be installed at the existing location and reconnected to reestablish the same electrical service and power currently provided to the property. Work will include removal of the existing S.E.S., installation of the new equipment, reconnection of existing electrical services, and coordination with the utility as required.
Construction activities are not restricted in general, but outside noise attributed to construction is limited to the following hours: Regular Hours (October 16 – April 30) · Monday–Friday: 6:00 a.m. to 8:00 p.m. (5:00 a.m. for concrete pouring) Summer Hours (May 1 – October 15) · Monday–Friday: 5:00 a.m. to 7:00 p.m. (4:00 a.m. for concrete pouring) · Saturday: 7:00 a.m. to 7:00 p.m. Work that generates noise outside of these hours requires approval and an after-hours permit. After-hours
The proposed project is the development of a 5-acre area (Parcel 62 located in the northwest quadrant of the airport), known as the Mesa Hangars/Davcon Aviation project. The development will include the construction of aircraft hangars that may include office and aircraft space. Specifically, the project will include roughly 50,000 square feet of aircraft hangar space, as well as approximately 20,000 square feet of office/administration space for the aviation businesses which rent the hangars, a
Commercial Building Permit
New 13,131sf office/warehouse building with multiple shell suites, including 814sf attached awnings. VB construction. B/S1 Occupancy. Include site improvements. Lot 15 and 16 combined. New 1.5-inch landscape meter on existing 2-inch service line and new 1.5-inch domestic meter on existing 2-inch service line. 1000 amp main electrical service. Special inspection required for steel, concrete, masonry, welding, epoxy. Deferred Fire Sprinkler, Fire Alarm and access control. Results in CofO.
New 15,837 office/warehouse building with multiple shell suites, including 914sf attached awnings. VB construction. B/S1 Occupancy. New 1.5-inch domestic water service and meter. 1000A main electrical service. Special inspection required for steel, concrete, masonry, welding, epoxy. Deferred Fire Sprinkler, Fire Alarm and access control. REF: PMT26-04565 revise roof framing from steel joist to wood trusses, added restroom in suite B110, and change of RTU from Evap Coolers to Package Heat pum
Tenant improvement of fire sprinkler for suite 5
Tenant improvement fire sprinkler suite 6
Modify existing fire alarm system by adding (5) ceiling-mounted horn/strobes, (2) ceiling-mounted strobes, (1) duct smoke detector, and relay for hood fire suppression. Related to PMT26-00272. Results in CoC.
Construction, repair, remodeling, demolition, and excavation work may be conducted between 6:00 a.m. through 7:00 p.m. Monday through Friday and 7:00 a.m. through 7:00 p.m. on Saturday. Work outside of this timeframe requires an afterhours/noise permit. After Hours permits for construction are subject to the following conditions and Building Official approval: A. The applicant must provide the following information: 1. Location of work: 3441 S. 80th St. Mesa, AZ 85212 2. Schedule of hours and da
Commercial Building Permit
Engineered repair of (5) damaged joists in suite H. Special inspection for repair observations, welding, wood framing. Results in CoC.
Install 8-foot iron fence with (5) manual truck gates and (1) pedestrian gate with free egress around loading dock area of existing building. Results in CofC.
New PV system on rooftop of an existing building. Install (182) new PV array panels, (1) AC combiner panel, (1) Alsoenergy DAS, (3) PV power inverters, (1) 400A utility disconnect switch, and (1) new 320A 3 phase PV electrical meter. Results in CofC.
Install of new 420 SF, type III-B, group U occupancy free standing aluminum shade structure over existing bldg rear entry/exit. Shade canopy is 15ft x 28ft with (6) posts with footings. ADM26-00630 approval for site modification for addition of shade structure. Results in CoC.
This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. D
POTHOLING utilities for design and discovery
Demolish exiting light pole in ROW. Install new light pole, wireless equipment, and 100A single phase pedestal electrical meter. Approved as noted. Results in CofC.
Install sensor release electronic locking systems on (3) egress doors at the office of a new hanger building (PMT23-04321). Approved as Noted. Results in CofC.
Modify existing Notifier fire alarm system for replacement AHU and associated shutdown interface. Approved as noted.
Install (2) new shade structures (952 SF total) at playground area of an existing City of Mesa park. Electrical power to shade structure lighting under site improvement permit (PMT26-05268). Playground equipment installed under PMT26-15046. Results in CofC.
Phase 1 and Phase 2 civil drawings for overall site.
AFP26-00653 THE PROJECT SCOPE INCLUDES MODIFICATIONS TO THE EXISTING 'D7' INFLATOR ASSEMBLY LINE (PMT23-12154) LOCATED IN THE PH. I / PRODUCTION AREA. EXIST. UTILITIES WILL NOT BE MODIFIED FOR THE PROJECT. EXIST. HAZARDOUS MATERIAL QUANTITIES WILL NOT BE INCREASED FROM THOSE PREVIOUSLY PERMITTED UNDER PMT23-12249.
Install 25,000 sf of high piled storage racking. Maximum storage height of 24 feet. Special inspection for anchoring. Approved with stipulations. See comments. Results in CoC.
Replace existing site chilled-water supply and return piping serving Buildings 510, 520, 521, 530, 531, 533, 540, 543, 560, 580, 581 and 591, including new isolation valves, building connections, trenching, backfill and site restoration. Install two new 200-HP tertiary chilled-water pumps at Building 541, associated pump pedestal, structural pipe supports and foundations, and electrical modifications. No new water meters. Special inspections for post-installed anchors, structural steel, concrete
New 201 SF, construction type II-B, F-1 occupancy sampling room expansion with requited 1-hour fire rated exterior wall. Scope includes renovations in the existing construction I-A, H occupancy building. Including unloading pump foundations and utility rack, electrical infrastructure upgrades, minor HVAC upgrades, removal of an existing overhead door, and infilling with 2-hour fire rated panels. Special inspection for fire-rated assemblies, steel, concrete, soils, and post-installed anchoring. D