PermitDig

Search Permits

2,919 results · type: commercial

LIKE FOR LIKE REPAIR/REPLACEMENT OF DAMGED METER, DIRECTION RECEIVED FROM SRP.

1925 S SOSSAMAN RD, Mesa
Aug 19

Install of site sport amenities: (2) sand volleyball courts, (4) pickle ball court and (2) hot tub spa with prefab support bldg with 6ft fencing and gates. Modified premanufactured spa bldg 320 SF, type IIB construction, group U occupancy. Manual vehicle gates at volleyball courts. Pickleball shade canopy as separate permit. Approved with stipulations. Results in CoC.

4503 S POWER RD, Mesa
Aug 18

potholing utilities for design and discovery

104 E MAIN ST, Mesa
Aug 18

Exterior mechanical and electrical modifications to provide cooling for 47 existing generator/DEF enclosures, 8 ISP electrical cabinets, and 4 Perun transformer control panels. Scope includes new HVAC equipment and associated electrical power. This City of Mesa permit is limited to the site-installed mechanical and electrical work only. Results in CoC.

7232 E ELLIOT RD, Mesa
Aug 18

Widen the existing ingress/egress driveway at the Higley Road access point to a total width of 71 feet.

3228 N HIGLEY RD, Mesa
Aug 18

Install 19.5 ft x 20 ft (390 SF total) pre-engineered aluminum shade cover over patio area at an existing building. Results in CofC.

2520 S ALMA SCHOOL RD, Mesa
Aug 18

New multi-tenant shell retail shop and associated site work. Type V-B construction with 7,225 SF tenant space and 1,700 SF of canopy. Civil and landscape under PMT25-11661. (5) new electric meters, water meters under civil permit. Deferred fire sprinklers and fire alarm. Special inspection for structural items and electrical service 1000 amps or more. Results in a CoC.

5115 S ELLSWORTH RD, Mesa
Aug 18

Emergency Responder Radio Coverage System

3261 S HAWES RD, Mesa
Aug 18

Existing warehouse building. New electrical 200A 3 phase meter and interior panel for lighting. Results in CofC.

8345 E PECOS RD, Mesa
Aug 18

Interior tenant improvement: remodel of old office spaces, re-configuring interior layout, electrical, plumbing, partition walls, drywall, paint, etc. Deferred fire sprinklers and fire alarm. Special inspections required for screw anchors in concrete and for steel construction. Results in C of C. Ref: PMT24-19511

4435 E HOLMES AVE, Mesa
Aug 18

ELECTRIC PERMIT FOR INSTALLATION OF ELECTRIC METER PEDESTAL FOR TRAFFIC SIGNAL.

4425 E MAIN ST, Mesa
Aug 18

FIRE DAMAGE REPORT - FIRE OCCURED 5/5/19 IN THE OFFICE. THE OFFICE WAS TOTALLY DESTROYED. BATHROOM AND LAUNDRY ROOM DAMAGE. manger office (commercial) , office at time of inspection has been gutted to stud, not structural damage, there are 3 room next to office that have water and smoke damage , (note that there room I could not get into) smoke damage to smoke truss and could have spread to other area were ceiling still in place, replace duct work that is damage , must have licensed electri

1006 W MAIN ST OFFICE, Mesa
Aug 18

Lift station for commercial development

8811 E WARNER RD, Mesa
Aug 18

New above ground 1000gal fuel tank with new concrete pad, related electrical work, and associated demolition work. Approved with comments. Results in CoC. Approved with Stipulations.

7035 E SOUTHERN AVE, Mesa
Aug 17

NEW RETAIL BUILDING FOR THE USE OF GOODWILL STORE AND DONATION CENTER ON NEW SHOPPING CENTER DEVELOPMENT LOCATED AT THE INTERSECTION OF GREENFIELD ROAD AND BASELINE ROAD IN MESA,ARIZONA. THIS PROJECT WILL INCLUDE A DRIVE-THRU DONATION LANE FOR RECEIVING DONATIONS. THIS STORE WILL PROCESS THE DONATIONS AND PROVIDE ITEMS FOR RE-SALE TO THE PUBLIC. Per Conditions of Approval of ZON25-00967 Replace all dead or dying landscaping at the parking area and perimeter of the project site. Deferred fire sp

1855 S GREENFIELD RD, Mesa
Aug 17

Uograding the well site at 3522 E University Dr

3522 E UNIVERSITY DR, Mesa
Aug 17

Development of restaurant shell building, Type V-B construction, 2,749SF building with 363 SF covered patio, Group A-2 occupancy. Development includes Civil Site Improvements. Special Inspections Required for Type 1 Hood Grease Duct Wrap, Fabricators, concrete, masonry, steel, anchors and soils. (1) 1.5inch domestic water meter, (1) 3/4inch irrigation meter, (1) 1,312CFH Gas meter, and (1) 3ph Elect meter. Deferred fire sprinklers, fire alarms, Co2 leak detection and hood fire suppression, pre-m

3445 S ELLSWORTH RD, Mesa
Aug 14

Install Sewer Tap and Sewer Line extension to existing Rest Room at the Sunland Village East R.V. Storage.

2050 S BUTTERCUP, Mesa
Aug 13

Install new domestic 1-inch water meter service line and 1-inch water meter at existing building and connect to existing building (internal) water line. Connection to existing 3/4" water meter along Macdonald to be terminated. Results in CofC.

42 S MACDONALD, Mesa
Aug 13

Remove and replace AFFF foam with new NFF foam. Includes new tank, valves and associate piping. Existing sprinkler heads and associated piping to remain. New hydraulic calculations for updated density requirement for new foam provided. Approved with Stipulations: Per design, a 700-gallon CHEMGUARD bladder tank is required to meet the 633 concentrate gallons needed. 2024 IFC as adopted is the applicable code. City Code, Title 7, Chapter 2

6533 S MOUNTAIN RD, Mesa
Aug 13

Tenant improvement of existing 28,275 SF type VB construction group E, A3 B and S1 occupancy Boys and Girls Club. Modification of approx. 13,000 SF existing space to include new walls and doors to create various education rooms, admin offices, new reception area, and restroom facilities. Main Gym is separated from remainder of bldg by existing 2hr fire wall. Scope includes building addition of 2,918 SF to provide secure lobby, conference and additional education space. Associated MEP scope: mech

221 W 6TH AVE, Mesa
Aug 13

New above ground 1000gal fuel tank with new concrete pad, related electrical work, and associated demolition work. Approved with comments. REF: PMT21-10097 Site Lighting. Results in CoC. Approved with stipulations.

830 S STAPLEY DR, Mesa
Aug 13

Install new 1000 gallon propane tank and associated equipment for refilling portable tanks at existing hardware store. New concrete pad, bollards, and masonry screen wall. New electrical and structural. Special inspections required: masonry construction. Per approved ADM26-00403 1. Remove two parking spaces along the southwest corner of the building, one for the installation of a new 1,000 -gallon, above-ground propane storage tank. The space directly to the east of the proposed tank will become

2758 S CRISMON RD, Mesa
Aug 13

New pony chiller and wet side economizer to the existing chiller plant for existing building. New MEP. Special inspections required: concrete construction, expansion bolts, and epoxy anchors. Results in CoC.

5000 E MCDOWELL RD, Mesa
Aug 13

Install new cold plunge pool, spa, and associated equipment at new building (PMT24-19616). New structural and electrical. Special inspection concrete construction. Results in CoC.

3651 S POWER RD, Mesa
Aug 13

Install 7 parking canopies totaling 8,905 SF at a new facility. Special Inspections required: concrete construction, welding, and soils. Results in CofC

10464 E PECOS RD, Mesa
Aug 13

THIS SUBMITTAL IS FOR CIVIL AND LANDSCAPE PERMIT ONLY TO SEPARATE THE WORK FROM THE NOX DEVELOPMENT PLANS. CONTACT ROBERT APODACA.

7244 E RAY RD, Mesa
Aug 13

add 1200A distribution board from an existing distribution board for several disconnects (2) 600a (2) 100A (3) 30A. For testing of HVAC equipment.

7337 S 80TH ST, Mesa
Aug 13

Interior tenant improvement. Deferred fire sprinklers.

1058 N HIGLEY RD 208, Mesa
Aug 13

Replacement of off-site Streetlight poles on McKellips Rd as Warranty Work due to Manufacturer defects.

6543 E MCKELLIPS RD, Mesa
Aug 12