Repairing the churches spire with the same existing product, copper. Spire construction will require 135’ articulating lift and road closures. Replacing the steep slope portion of the roofing system, all roofs currently installed with a metal or aluminum type roofing shingle. Replacement product will be with a metal, or stone coated steel roofing shingle.
Commercial Building Permit
Commercial Building Permit
Install CO2 monitoring system with horn strobes. Existing CO2 tank.
Replace storm damaged SES and house panel. Install new electrical meter. Special inspection required for electrical work. Reviewed as noted. Results in CoC.
solar_commercial_or_modification_(any_land-use)
Commercial Building Permit
Commercial Building Permit
New Development of a 1-story, 29,995 SF, type V-A construction, group R-2, A-2, A-3 and B non-separated occupancies, 85-bed dormitory with attached medical clinic. Medical clinic area includes (8) exam rooms, (2) wound care, nurse stations, lab, medical supply and Rx room. The Dormitory includes shared bathrooms, Day rooms, kitchen, cafeteria, offices, meeting rooms, utility rooms and storage spaces. Special inspection req. - steel, concrete, masonry, soils, fire-resistant penetration & joints,
Install four (4) dual EV chargers in parking lot of existing building. Existing electrical supply. Results in CofC.
Fire Alarm - connection of duct smoke detectors to shell FACP for offiste reporting.
Install access control and alarm system in new building.
Civil improvements to existing site entrance at the MSA Data Center, to include driveway widening, additional parking expansion and install of (2) Pre-Engineered Metal Bldgs.: (32 SF) Guard Shack and (393 SF) Trucker Driver Shelter. Scope to include associated site lighting relocation and new elect panel from exist generator. Special inspection req. for soils and concrete. Results in CoC.
Install irrigation system related to PMT23-14420. Landscaping to comply with approval of BOA23-00397. Results in CoC.
Installation of (2) equipment platforms approx. 700 SF and 760 SF in an F-1 occupancy area within an existing 130,376 SF, type II-B construction, group B, F1 and S1 building. Special inspection req. Epoxy/Expansion anchors, concrete, steel, welding. Deferred fire sprinklers. REF: PMT26-06512 for Building TI associated permit. Results in CoC.
Construction of a new one-story restroom and pool equipment building serving the private Hawes Crossing residential community pool. The project includes common-use men’s and women’s restrooms, an adjacent pool equipment area, an exterior rinsing/shower area, accessible facilities and routes, and associated structural, plumbing, mechanical and electrical work. Building plan review is requested to proceed concurrently with Planning review. Planning approval and stamped plans are pending completio
Electrical Service Upgrade
Repair broken electrical flex line and missing j-box cover plate per annual fire inspection of property. RV Park
Interior fitout of one data hall and the addition of the second equipment yard on the East side of the building. Architectural scope includes the interior fitout of the data hall and its associated mechanical galleries as well as several storage rooms. Scope also includes new screen walls enclosing the East yard. Civil scope includes grading around the East yard and concrete sidewalks. Mechanical scope includes new equipment inside the data hall galleries and new chillers on the rooftop dunnage
Install manual fire alarm system with occupant notification devices in a temporary dining tent with a Group A-2 occupancy and no fire sprinkler system. System primarily powered by temporary generators and backup batteries. Approved with Stipulations IFC 901.4: Provide four (4) exterior horn/strobe notification appliances, with one installed on each side of the tent structure. Fire alarm system shall always remain fully operational and compliant with required standards (24/7).
AFP26-01281 Replacing two exhaust fans and four air handling units with equipment of similar capacity.
Commercial Building Permit
Commercial Building Permit
Commercial Building Permit
construct new 2-story wood frame 7,398 sq. ft. building and site improvements. Type of Construction is VB AFES and Occupancy is B/S1 non-separated uses and R-3 non separated uses. Deferred fire sprinklers and fire alarm. Approved as noted.
Replace old horn strobe fire alarm system with a new voice evacuation fire alarm system to meet "E" occupancy code requirements.
Installation of Emergency Responder Radio Coverage System (ERRCS), including head-end equipment, fiber backbone, antennas, associated cabling, and electrical connections. Includes underground inter-building fiber and interior armored fiber in cable tray. Approved with Stipulation: The in-building emergency responder communications enhancement system shall be monitored by a listed fire alarm control unit in accordance with IFC 510.4.2.5. Results in CoC.
UNAUTHORIZED CONSTRUCTION. COB26-00053 - Create a maintenance storage shed in rear of property. Size approx. 288 sq ft 12x24
Remodel of existing type V-B construction fuel station and lube express shell building to a 3,092 SF fast service restaurant with drive thru. Remodel of existing type V-B construction carwash to a 4,639 SF new carwash with outdoor self-service vacuum bays. Addition of 6 FT masonry wall on east interior lot line for the ambient noise evaluation. (1) new gas meter and (1) new 1,000 AMP SES. Deferred fire sprinklers and fire alarm. Special inspections for structural, EIFS, electrical. Results in Co
AFP26-01281 - Like for like replacement of (6) automatic transfer switches.