tenant_improvement_(interior_only)C of o issued

Tenant improvement in existing 186,057 SF, type VB construction, group B and S1 Dynaelectric Facility. Modification include converting 5,310 SF of S-1 warehouse space into an expanded office area with offices, conference rooms and (4)new ADA restrooms, replacement of exterior entry door and associated MEP/FS. Special inspection req. - steel and concrete. Deferred fire sprinklers. Results in CoO for new office area.

9029 E PETERSON AVE, Mesa, AZ

Permit Details

Permit Number
PMT26-11204
Type
tenant_improvement_(interior_only)
Status
c of o issued
Issued Date
November 13, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Steve Calvert

About tenant_improvement_(interior_only) Permits in AZ

0

tenant_improvement_(interior_only) permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

CONSTRUCT A 260 SF SWIMMING POOL & 49 SF SPA. INSTALLATION OF ONE 120-GALLON VERTICAL PROPANE TANK.37-FT OF 1.5 -IN GALVANIZED GASLINE BURIED 18-IN WITH 18 GAUGE TRACER WIRE FROM TANK TO 400K BTU POOL HEATER. GASLINE TO BE INSTALLED PER 2018 IFGC & FPD 6104.1.. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED T

2534 E PRESIDIO ST · PMT26-11006

Tenant improvement within an existing 125,303 SF Type V-B building for item America. Tenant improvement area is approximately 62,562 SF and includes existing office, S-1 storage/warehouse, and F-2 low-hazard manufacturing areas for manufacturing and distribution operations. Scope includes electrical modifications, equipment power, compressed-air distribution, and associated life-safety provisions. Demising wall and fire sprinklers under PMT26-10053. High-piled combustible storage under separate

9512 E ELLIOT RD 131 · PMT26-11446

Underground and foundation only. Under slab utilities, New unlimited area construction II-B, 188,093 SF data center. Civil PMT26-09201. Special inspection for soils and concrete. Results in CoC.

10256 E ELLIOT RD · PMT26-09976

Tenant improvement in existing 98,938 SF, type VB construction , F2 and S-2 occupancy manufacturing warehouse. Modification to include install of 2,935 SF mezzanine within warehouse, new breakroom area, (2) restroom facility, locker and change room area, structural foundation and slab reinforcement for equipment and overhead crane, (6) new RTUs and associated plumb and elec. High Piled Storage Racking and High Piled Combustible Storage will be by separate submittal. Special inspection req. - Ste

Unknown · PMT26-10149

Similar tenant_improvement_(interior_only) Permits

Tenant improvement within an existing 125,303 SF Type V-B building for item America. Tenant improvement area is approximately 62,562 SF and includes existing office, S-1 storage/warehouse, and F-2 low-hazard manufacturing areas for manufacturing and distribution operations. Scope includes electrical modifications, equipment power, compressed-air distribution, and associated life-safety provisions. Demising wall and fire sprinklers under PMT26-10053. High-piled combustible storage under separate

Mesa, AZ · PMT26-11446

Tenant improvement in existing 98,938 SF, type VB construction , F2 and S-2 occupancy manufacturing warehouse. Modification to include install of 2,935 SF mezzanine within warehouse, new breakroom area, (2) restroom facility, locker and change room area, structural foundation and slab reinforcement for equipment and overhead crane, (6) new RTUs and associated plumb and elec. High Piled Storage Racking and High Piled Combustible Storage will be by separate submittal. Special inspection req. - Ste

Mesa, AZ · PMT26-10149

Install storage rack system in an existing warehouse suite. Special inspections required: post-installed anchors. Results in CofC.

Mesa, AZ · PMT26-07490

Interior tenant improvement of an approximately 10,000 SF medical spa within a new gray shell building. Work includes new interior partitions, doors, finishes, millwork, and lighting, along with mechanical, electrical, and plumbing systems required to support the spa and wellness functions. The project will be designed and coordinated with structural and MEP engineering consultants. No exterior modifications approved as part of this permit. Deferred fire sprinklers. Results in CoO.

Mesa, AZ · PMT26-04958

PAD 6 - Tenant will be adding windows to the office and electrical for TV's and fans. Looking to obtain certificate of occupancy.

Mesa, AZ · PMT26-14545

About tenant_improvement_(interior_only) Permits in Mesa, AZ

What is a tenant_improvement_(interior_only) permit?

A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.