Demo existing kitchen equipment and waste lines at area of work to occur. Demo existing Type I hood, associated ducting, and roof top exhaust fan. New Captive Air Type I kitchen hood exhaust system, fire suppression system, grease duct, and associated equipment. New roof top exhaust fan and grille. Trench for new floor sink tie new waste line into existing grease waste line. New vent from floor sink to ceiling and tie into nearest existing vent through roof. New exhaust fan for relocated combin

1331 S COUNTRY CLUB DR, Mesa, AZ

Permit Details

Permit Number
PMT26-03302
Type
tenant_improvement_(interior_only)
Status
c of c issued
Issued Date
October 20, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Kim Filuk

About tenant_improvement_(interior_only) Permits in AZ

0

tenant_improvement_(interior_only) permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

Civil improvement plans only. REF: PMT26-08579 for bldg. Water Meters: (1) 1-inch landscape.

5118 S 71ST ST · PMT26-10001

CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 24-FT X 26-FT 2026 ABOVE GROUND SET CLAYTON MH SERIAL NO. BUC017864AZAB WITH A/C AT REAR.GAS. ONE 13-FT X 40-FT ATTACHED AWNING PER ICCESR 1398. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN TWO 9-FT X 18-FT W/ ONE SPACE MUST BE COVERED, PAVED WITH 2-IN OF ASPHALT OR 4-IN OF CONCRETE, UNOBSTRUCTED PARKING SPACES BEHIND FRONT SETBACK. 44-FT X 81-FT PERIMETER LOT. MIN SETBACKS: 1-FT FRONT, 4-FT REAR, 3-FT MH SIDE, 1-FT AWNING SIDE, MI

345 S 58TH ST 32 · PMT26-11388

Interior mechanical gallery partition walls within approximately 53,218 SF of the second floor of an existing construction type II-B building. Scope limited to architectural wall construction only. No mechanical, electrical, or equipment installations under this permit. Existing shell building under PMT24-06075. Reviewed as noted. Results in CoC.

8807 E WARNER RD · PMT26-12295

Install (2) exterior wall mounted illuminated signs with pan channel lettering: FIFTH THIRD BANK w/logo 24.5 sq ft each.

1825 S VAL VISTA DR · PMT26-09415

Similar tenant_improvement_(interior_only) Permits

Interior mechanical gallery partition walls within approximately 53,218 SF of the second floor of an existing construction type II-B building. Scope limited to architectural wall construction only. No mechanical, electrical, or equipment installations under this permit. Existing shell building under PMT24-06075. Reviewed as noted. Results in CoC.

Mesa, AZ · PMT26-12295

Group B occupancy. Type V-B construction. 3,991 SF. Occupant load 27. Demo partition walls, doors, and door frames. Remove front entrance doors to switch swing outward. New partition walls, doors and door frames to reconfigure offices in existing suite. Relocate mechanical supply diffusers and return grills. Results in CofO.

Mesa, AZ · PMT26-04208

Tenant improvement scope of work area is 23,000 SF of S1 warehouse space converted to a group F1 occupancy in an existing 108,000 SF, type II-B construction warehouse space of Building 543. Modifications include relocate Tooling operations from buildings 531 & 532 and into building 543 and includes architectural, structural, mechanical and electrical. Deferred fire sprinklers and fire alarm. Approved with comments. Results in new partial CoO for warehouse space.

Mesa, AZ · PMT26-11479

Tenant improvement of existing 18,000 SF type V-B construction, group A3 occupancy. Modification includes demo of check-in area, reconfiguration of fun store and reduction at party room area to relocate prep area at back of house, and associated mechanical, plumbing and electrical. Less than 10 fire sprinkler heads will be added/modified. Results in CoO

Mesa, AZ · PMT25-07936

A ± 5,996 SQ. FT. INTERIOR REMODEL WITHIN AN EXISTING WAREHOUSE IN THE FUJIFILM FACILITY. THE SCOPE OF WORK INCLUDES A NEW MEZZANINE TO BE ADDED OVER THE EXISTING FINISH GOODS STORAGE AREA. THE FIRST FLOOR INCLUDES A NEW PROCESS AREA, A NEW MAN DOOR, AND A NEW OVERHEAD DOOR FOR EXISTING FORKLIFT TRAFFIC. THE MEZZANINE WILL CONSIST OF TWO NEW PRIVATE OFFICES, AND AN OPEN OFFICE SPACE, ALONG WITH TWO NEW STAIRWELLS FOR STAFF USE. FIRE PROTECTION WILL BE PROVIDED AS REQUIRED AROUND THE MEZZANINE AN

Mesa, AZ · PMT26-13635

About tenant_improvement_(interior_only) Permits in Mesa, AZ

What is a tenant_improvement_(interior_only) permit?

A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.