CONSTRUCT A 394-SF SWIMMING POOL AND A 49-SF SPA. NO GAS UNDER THIS PERMIT. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER - ALAN E. MONEY NO. 30895, EXPIRES 12-31-26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL AND SPA CODE
11108 E UTAH AVE, Mesa, AZ
Permit Details
- Permit Number
- PMT26-17658
- Type
- swimming_pool
- Status
- issued
- Issued Date
- October 22, 2026
- County
- Mesa, AZ
Parties
- Contractor
- RIDER PERMIT SERVICE
About swimming_pool Permits in AZ
0
swimming_pool permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Extend an underground gas line from an existing outdoor bbq to a new bbq about 25' away.
2421 N MALACHITE · PMT26-19017
Contractor will add a wall and door to close off current den area to a 3rd bedroom. The space has a cut out area where there are currently cabinets. Cabinets will be removed and a wall with sliding closet door will be added to create a closet area for 3rd bedroom. The den area already has two windows to the outside as well. If you look at other same floor plans in the neighborhood (Rancho De Arboleda), all of them are already 3 bedrooms. My home was built with it as an open den concept, but it s
2233 N WINTHROP CIR · PMT26-19391
CONSTRUCT A 281 SF SWIMMING POOL & 54 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 2-IN PE PIPE FROM EXISTING GAS METER TO 1ST TEE, 2-IN PE PIPE FROM 1ST TEE TO 2ND TEE, 2-IN PE PIPE FROM 2ND TEE TO 400K BTU POOL HEATER, 1-IN PE PIPE FROM 2ND TEE TO 100K BTU BBQ, 1-IN PE PIPE FROM 1ST TEE TO 3RD TEE, 3/4 PE PIPE FROM 3RD TEE TO 1ST 75K BTU FIRE WOK, AND 3/4-IN PE PIPE FROM 3RD TEE TO 2ND 75K BTU FIRE WOK. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF
9936 E STROBE AVE · PMT26-11528
R-4 OCCUPANCY GROUP CONDITION 1. Community Residence Registration Application and Certificate of Occupancy for a residential care home operating as a Family Community Residence - Residential Behavioral Health. Name: Community Healthcare System, LLC. Applicant requested 8 number of residents. MZO allows up to 10 residents, excluding staff. No skilled nursing services. 24-hour care. R-4 Occupancy Group Condition 1. MBC 310.5: This occupancy condition shall include buildings in which all persons r
1031 S CANFIELD · PMT26-07911
Similar swimming_pool Permits
swimming_pool
New Orleans, LA · 26-28978-POOL
CONSTRUCT A 281 SF SWIMMING POOL & 54 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 2-IN PE PIPE FROM EXISTING GAS METER TO 1ST TEE, 2-IN PE PIPE FROM 1ST TEE TO 2ND TEE, 2-IN PE PIPE FROM 2ND TEE TO 400K BTU POOL HEATER, 1-IN PE PIPE FROM 2ND TEE TO 100K BTU BBQ, 1-IN PE PIPE FROM 1ST TEE TO 3RD TEE, 3/4 PE PIPE FROM 3RD TEE TO 1ST 75K BTU FIRE WOK, AND 3/4-IN PE PIPE FROM 3RD TEE TO 2ND 75K BTU FIRE WOK. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF
Mesa, AZ · PMT26-11528
Desert Uplands Envelope lot - All work related to swimming pool and spa is within the existing temporary fence. No new disturbance with this permit. The temporary fence is required to remain in place per the approved site plan at all times during construction. All areas out of the approved disturbance area shall remain undisturbed at all times. Property line fencing is not permitted. A separate zoning inspection is required prior to final building inspection. Reference temporary fence permit P
Mesa, AZ · PMT26-12819
CONSTRUCT A 450-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT NO.58912, EXPIRES 12-31-26. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS.
Mesa, AZ · PMT26-14975
CONSTRUCT A 736-SF SWIMMING POOL & 64-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 90-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14-GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 15-FT OF 2-IN PE GAS LINE TO 65K BTU BBQ, AND 25FT OF 2-IN PE GAS LINE TO 50K FIRE PIT. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCE
Mesa, AZ · PMT26-17524
About swimming_pool Permits in Mesa, AZ
What is a swimming_pool permit?
A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.