PermitDig
swimming_poolIssued

CONSTRUCT A 448-SF SWIMMING POOL & 72-SF KID POOL. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: TODD L. LACHER #45083, EXPIRES 9/30/27. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS.

3352 E HOPI AVE, Mesa, AZ

Permit Details

Permit Number
PMT26-15483
Type
swimming_pool
Status
issued
Issued Date
October 6, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Jose Avila

About swimming_pool Permits in AZ

0

swimming_pool permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

Civil improvement plans only. REF: PMT26-08579 for bldg. Water Meters: (1) 1-inch landscape.

5118 S 71ST ST · PMT26-10001

CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 24-FT X 26-FT 2026 ABOVE GROUND SET CLAYTON MH SERIAL NO. BUC017864AZAB WITH A/C AT REAR.GAS. ONE 13-FT X 40-FT ATTACHED AWNING PER ICCESR 1398. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN TWO 9-FT X 18-FT W/ ONE SPACE MUST BE COVERED, PAVED WITH 2-IN OF ASPHALT OR 4-IN OF CONCRETE, UNOBSTRUCTED PARKING SPACES BEHIND FRONT SETBACK. 44-FT X 81-FT PERIMETER LOT. MIN SETBACKS: 1-FT FRONT, 4-FT REAR, 3-FT MH SIDE, 1-FT AWNING SIDE, MI

345 S 58TH ST 32 · PMT26-11388

Interior mechanical gallery partition walls within approximately 53,218 SF of the second floor of an existing construction type II-B building. Scope limited to architectural wall construction only. No mechanical, electrical, or equipment installations under this permit. Existing shell building under PMT24-06075. Reviewed as noted. Results in CoC.

8807 E WARNER RD · PMT26-12295

Install (2) exterior wall mounted illuminated signs with pan channel lettering: FIFTH THIRD BANK w/logo 24.5 sq ft each.

1825 S VAL VISTA DR · PMT26-09415

Similar swimming_pool Permits

CONSTRUCT A 512-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY NO.30895, EXPIRES 12-31-26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMEN

Mesa, AZ · PMT26-14427

CONSTRUCT A 736-SF SWIMMING POOL & 64-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 90-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14-GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 15-FT OF 2-IN PE GAS LINE TO 65K BTU BBQ, AND 25FT OF 2-IN PE GAS LINE TO 50K FIRE PIT. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCE

Mesa, AZ · PMT26-17524

INSTALL 392 S.F. POOL, 49 S.F. SPA, 110' OF 2" GAS LINE FOR 400K BTU HEATER AND 35' OF 1.5" GAS LINE FOR BBQ/EQUIP (PERGOLAS ON SEPARATE PERMIT)

Mesa, AZ · PMT26-19008

swimming_pool

New Orleans, LA · 26-27932-POOL

$59,027

CONSTRUCT A 1028 SQ FT SWIMMING POOL / SPA. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".

Mesa, AZ · PMT26-09956

About swimming_pool Permits in Mesa, AZ

What is a swimming_pool permit?

A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.