Adding a spa to an existing pool andding a jumping feature and a new stair way ro a slide

917 N BARKLEY, Mesa, AZ

Permit Details

Permit Number
PMT26-19715
Type
spa
Status
in review
Issued Date
November 2, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
ELITE LANDSCAPE & STONE LLC

About spa Permits in AZ

0

spa permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

CONSTRUCT A 312-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS

8052 E PETERSON AVE · PMT26-11949

Casita has been built already and I am looking to get it permitted. Re COD26-03737. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.

556 S CRESTON · PMT26-11912

New 875 SF Type V-B canopy and remodel of the existing concession stand. Scope of work includes demolition and replacement of the existing canopy, interior and exterior renovations to the concession kitchen and service area, associated mechanical, electrical, and plumbing (MEP) work, and finishes. Deferred truss calculations. Special inspections required for soils, concrete, and structural steel. Results in CoC.

2145 S FARNSWORTH DR · PMT26-10460

Tenant improvement at existing Banner Urgent care to convert an existing room into an Xray room. Modifications include removal of exterior door, interior walls, and saw cutting of concrete for utility, reconfigure existing room size, furred interior walls at window locations, new sink, lighting and associated MEP. Special inspection req. - post installed anchors. Deferred fire sprinklers. Approved with comments. Results in CoC.

1121 S GILBERT RD 102 · PMT26-03601

Similar spa Permits

CONSTRUCT A 38-SF SPA TO EXISTING SWIMMING POOL. REFERENCE PMT17-03260. REPLACING EXISTING WATERFALL WITH NEW WATERFALL. INSTALLATION OF 52-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14-GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 12-FT OF 1-IN PE GAS LINE TO 75K BTU BBQ. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC AND COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE

Mesa, AZ · PMT26-19178

Building a 10x8 in ground Spa

Mesa, AZ · PMT26-19014

CONSTRUCT A 64 SF SPA WITH EXISTING SWIMMING POOL AND EQUIPMENT UNDER HOST NO. 181653. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE

Mesa, AZ · PMT26-17246

CONSTRUCT A 38-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 128-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 18-GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER AND 250K BTU GAS GENERATOR. INSTALLATION OF 60-FT OF 1-IN PE GAS LINE TO 180K BTU TANKLESS WATER HEATER FOR ADU, REF. PMT25-15529 FOR THE ADU. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS

Mesa, AZ · PMT26-11103

CONSTRUCT A 33-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 128-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14-GAUGE TRACER WIRE FROM EXISTING 35-FT, 2-IN GAS LINE TO 75K BTU FIRE PIT, 52-FT OF 2-IN PE GAS LINE TO 50K BTU BBQ. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED OR NO SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCT

Mesa, AZ · PMT26-12347

About spa Permits in Mesa, AZ

What is a spa permit?

A spa permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.