NEW 2903 SF TWO STORY RESIDENCE WITH 2+ CAR GARAGE IN HAWES CROSSING. INCLUDES NEW WATER, GAS AND ELECTRIC METER. SPECIAL INSPECTIONS FOR POST TENSION SLABS. SEE MST23-16142 FOR STRUCTURAL CHANGES. ADDENDA MST25-01219 - SHEETS A2.1-A2.3 · REVISED SGD TO A 3050 SH WINDOW AT LEFT ELEVATION: PARCEL ADDITION, SHEET S1.01 ADDED PARCEL H INFORMATION· REVISED GEOTECHNICAL REPORT DATES: SHEETS S1.07 -S1.12 - ADDED SHEETS FOR 9 1/2" FOUNDATION FOR PARCEL F.
7842 E RAMBLEWOOD AVE, Mesa, AZ
Permit Details
- Permit Number
- PMT25-18825
- Type
- single_family_(detached)
- Status
- c of o issued
- Issued Date
- April 10, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Nihya Moscoso
About single_family_(detached) Permits in AZ
0
single_family_(detached) permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES
7824 E JEROME AVE · PMT26-11463
New 10,780 SF, construction type V-B shell office and warehouse building for future Group B and S-1 occupancies, with 209 SF canopy. Scope includes the building shell, 4-hour fire separation on property line. MEP's, site improvements, canopy, and enclosed rear storage yard. New 600 AMP electric meter. New water 1.5-inch domestic and 1-inch irrigation meter. Deferred steel joists, fire alarm, fire sprinklers, and vehicular gate access. Special inspections required for soils, concrete, masonry, s
Unknown · PMT26-11786
Install (2) illuminated exterior building signs and (2) non-illuminated ground signs. Results in CofC.
8016 E PECOS RD · PMT26-11955
Create new additional parking spaces for an existing building in retention basin. Install new unground stormwater chambers at new parking area. ADM26-00284 special use permit for additional 15 parking stalls and addition of underground retention. Approved as noted. Results in CofC.
724 W UNIVERSITY DR · PMT26-10189
Similar single_family_(detached) Permits
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
Mesa, AZ · PMT25-23465
NEW 3399 SF TWO STORY RESIDENCE WITH 2+ CAR GARAGE IN HAWES CROSSING. NEW GAS, WATER AND ELECTRIC METERS. SPECIAL INSPECTIONS FOR POST TENSION SLABS **SEE ADDENDA MST25-07604**
Mesa, AZ · PMT26-07206
IRC 2018 FOR SINGLE STORY 2661 SF RESIDENCE WITH SEVERAL GARAGE AND BONUS ROOM OPTIONS.. WOOD FRAMED, TRUSSES, POST TENSION SLAB, STUCCO, CONCRETE TILE, STONE/BRICK VENEER. OPTIONS INCLUDE MASTER SUITE IN LIEU OF SINGLE CAR GARAGE AND TWO CAR GARAGE. SEE MST21-08860 FOR MONTELUNA . SEE MST21-12327 FOR THE RESERVE AT RED ROCK STRUCTURAL CHANGES. SEE MST22-01912 FOR EXTENDED LIVING ROOM AT THE RESERVE AT RED ROCK. SEE MST22-16752 FOR STRUCTURAL CHANGES AT THE GROVE AT LEHI. ADDENDA MST25-06777
Mesa, AZ · PMT25-22882
Construct new 3,863 SF livable single-story custom home with 1,278 SF non-livable area. Type V-B construction. New 3/4" water meter. New gas electrical meter, and sewer connections. Deferred roof truss calculations. Special inspections required for concrete construction including post-tensioned slab, post-installed concrete anchors and soils. Minimum required building inspections: Plumbing underground, footing, stem, pad elevation (conditional hold), strap/shear, frame, mechanical rough in, elec
Mesa, AZ · PMT26-16951
Dream Finders Homes Plan 3 - Master Plan – New Two Story Single Family Residence – Total livable area 2178 SF and total non livable area 703 SF. Type V construction. R-5 occupancy. New three quarter inch water meter, gas load 449000 BTU, and 200 amp electrical panel. Deferred submittals: truss drawings and fire sprinklers. Special inspections required for steel construction, concrete construction, and soils. Deferred Truss Calcs, and sprinklers. EV-Charger in garage.
Mesa, AZ · PMT26-07886
About single_family_(detached) Permits in Mesa, AZ
What is a single_family_(detached) permit?
A single_family_(detached) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?