REMODEL GARAGE TO SALES OFFICE FOR A MODEL HOME COMPLEX. ALL WORK SHALL COMPLY WITH 2024 IBC, 2024 IRC, 2023 NEC, 2017 ADA A117.1. THIS HOME IS NOT TO BE INHABITED UNTIL THE SALES OFFICE IS CONVERTED BACK TO A GARAGE. GARAGE AREAS MODIFIED OR IMPROVED FOR THE PURPOSE OF PROVIDING A TEMPORARY OFFICE SHALL BE RESTORED BACK TO A GARAGE PER PARKING STANDARDS IN CHAPTER 32 OF ZONING ORDINANCE PRIOR TO THE SALE OR RESIDENTIAL OCCUPANCY OF SUCH MODEL HOME. SECURITY STANDARDS TO BE MET PER SEC R328. T
3654 E SIERRA MORENA ST, Mesa, AZ
Permit Details
- Permit Number
- PMT26-17730
- Type
- other_commercial
- Status
- issued
- Issued Date
- October 27, 2026
- County
- Mesa, AZ
Parties
- Contractor
- RESERVE 100 LLC
About other_commercial Permits in AZ
0
other_commercial permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Tenant improvement in existing 11,599 SF, type III-B construction, B occupancy office warehouse suite. Modifications include demo of (1) restroom, sink with millwork, partial wall demo for new door opening, removal of exist OVH door system and parts of exist ceiling. install new partitions, to create an offices, (4) new ADA unisex restroom and open floor lab work area for laboratory testing and install of a 3,171 SF mezzanine for S1 Storage, new RTUs and associated Str and MEP. Special inspectio
2140 W BROADWAY RD 104 · PMT26-12357
CONSTRUCT A 340 SF SWIMMING POOL & 38 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 50-FT OF 2-INPE GAS LINE BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/
7243 E TASMAN ST · PMT26-11868
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 16-FT X 40-FT 2026 CLAYTON MANUFACTURED HOME ABOVE GROUND SET, SERIAL NO. BUC017860AZ, WITH A/C AT REAR. NO GAS. NO LP TANKS. ONE 11-FT X 35-FT AWNING PER ICCESR 1398 ATTACHED AWNING. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM OF TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK AND REQUIRED TO BE ON 2-IN ASPHALT OR 4-IN CO
2701 E ALLRED AVE 101 · PMT26-11997
Hawes Crossing Village 4 is a part of the Hawes Crossing master planned community located northeast quarter of Section 20, Township 1 South, Range 7 East of the Gila and Salt River Meridian. The Project is comprised of approximately 39 net acres planned for single family residential development. Approved with comments. Landscape meter included in Phase 1 under PMT25-03485.
8235 E WARNER RD · PMT26-10351
Similar other_commercial Permits
Group B occupancy. Type V-B construction. 8,548 SF. Occupant load 103. Existing suite and building. Demo existing partition walls and plumbing fixtures. Demo portion of exterior wall for a new entrance. New store front with door and 42 SF canopy over the new entrance. New partition walls and lighting. Remove existing mini-split air unit. New mechanical inline exhaust fat to the exterior of the building. New ceiling exhaust fan to exterior wall. New supply air ducting connecting to existing trunk
Mesa, AZ · PMT26-13188
Group A-3 and U occupancies. Type V-B construction. 4,501 SF. Occupant load 237. New semi-public pool, spa, restroom/equipment building in rental community REF: PMT20-09359. New structural, architectural, and MEP. Utilities provided under PMT20-09359.Special inspections required: masonry construction. Results in CofO.
Mesa, AZ · PMT26-15021
Install utilities and equipment for new Mesa sewer lift station. 208 SF Canopy. 2-inch domestic water meter service and 2-inch water meter. Electrical meter 200A 3 phase. Gas meter. Special inspections required: high strength bolting, steel construction, masonry construction, post-installed anchors, and concrete construction. Approved as noted. Results in CofC.
Mesa, AZ · PMT26-15401
Install 16 ev charing stations using 19 existing parking stalls. Details of sow include: installing (1) pad mounted utility transformer: (1) 2500a, 277/480v mcb switchboard: (2) tesla pre-assembled supercharger unit with (1) 1200a v4 supercharger cabinet & (8) v4 supercharger posts: 4) light poles: (4) waste management bins
Mesa, AZ · PMT26-17385
Install one new magnetic locking device on one existing commercial door. Existing fire alarm relay/interface to remain and be utilized for release of the magnetic lock upon fire alarm activation. No modifications to the existing fire alarm system are proposed. Work includes associated access control hardware and wiring.
Mesa, AZ · PMT26-17384
About other_commercial Permits in Mesa, AZ
What is a other_commercial permit?
A other_commercial permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.