Upgrade existing electrical panel to 400 amp service. No other utility changes. No deferred items. No special inspections. Minimum required building inspections: Electric rough in and electric final.
2528 S HOSICK, Mesa, AZ
Permit Details
- Permit Number
- PMT26-05551
- Type
- Electrical
- Status
- c of c issued
- Issued Date
- October 30, 2026
- County
- Mesa, AZ
Parties
- Contractor
- YOCOM LONNIE/SHERYL
About Electrical Permits in AZ
0
Electrical permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
New 1026 S.F. hobby garage w/ walk-deck on top - new exterior staircase to access walk-deck, w/ interior & exterior lighting. Truss calculations deferred. Special inspections required for masonry construction. Minimum required building inspections: Footing, stem, strap and shear, framing and final. If needed, underground electrical and plumbing.
3530 N HAWES RD 7 · PMT26-10609
Tenant improvement in existing 270,700 SF, type II-B construction, B, A2, F1, S2 and H3 occupancy facility. Modification area of approx. 300 SF in group F-1 area include interior installation of new thermal spray operations, relocation of exist equip, new roof mounted mechanical equipment and ground mounded dust collector in screen equipment yard north of bldg. Deferred fire sprinklers and fire alarm. Results in CoC.
10036 E GERMANN RD · PMT26-09720
Type III-B construction. Group B occupancies. 2,171 SF. Occupant load 53. New partition walls inside of an existing grey building to create spec office suite (West) with conference room, break room, and ADA compliant restrooms. New architectural, structural, and MEPs. Electrical meters are to be installed under PMT26-05958 (Suite 101). Special inspection required: Steel Construction and Expansion/Epoxy Anchors. Deferred fire sprinklers. Approved as noted. Results in CofO.
6566 S MERIDIAN RD · PMT26-07704
Type III-B construction. Group B occupancy. 2,171 SF. Occupant load 53. New partition walls inside of an existing grey building to create spec office suite (East) with conference room, break room, and ADA compliant restrooms. New architectural, structural, and MEPs. (4) new 1200A 3 phase electrical meters. Special inspection required: Steel Construction, Expansion/Epoxy Anchors, and Electrical Performance Testing. Deferred fire sprinklers. Approved as noted. Results in CofO.
6566 S MERIDIAN RD · PMT26-05958
Similar Electrical Permits
INSTALLATION OF A 60 AMP DEDICATED CIRCUIT BREAKER FOR A NEMA 14-50 OUTLET IN THE GARAGE. EXISTING 200 AMP SERVICE METER. ELECTRICAL SHALL BE INSTALLED PER MANUFACTURES SPECIFICATIONS AND COMPLY WITH 2024 IBC, 2023 NEC AND SRP STANDARDS.
Mesa, AZ · PMT26-15126
Installation of 22kw generator, sub panel, transfer switch, and dedicated gas line to existing SFR. Minimum required building inspections: Electric rough in and electric final, Gas rough in and gas pipe final, and final.
Mesa, AZ · PMT26-16748
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
Mesa, AZ · PMT26-18318
Add a 90a breaker to existing main panel, install a 125a sub panel on the opposite outside wall of the house, run aluminum #2 2-2-2-4 SER Cable through the attic to it, and install a 50a and 20a plug to breakers in the sub panel
Mesa, AZ · PMT26-18718
Install battery backup system AC coupled with existing solar
Mesa, AZ · PMT26-18847
About Electrical Permits in Mesa, AZ
What is a Electrical permit?
A Electrical permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.