NTT Global Data Centers Americas is adding an additional Data Center building in Mesa, Arizona as part of a 244MW master planned site. PH6 will consist of 8 vaults with prefabricated UPS electrical power modules, generators and closed loop air-cooled chillers located on the exterior. The initial buildout will consist of a core and shell, underground utilities and equipment pads, and a single 8 MW vault with 56 MW future vaults 2 through 8. The envelope will consist of tilt up concrete panels wit
10256 E ELLIOT RD, Mesa, AZ
Permit Details
- Permit Number
- PMT26-13890
- Type
- commercial/industrial_projects
- Status
- revisions required
- Issued Date
- October 22, 2026
- County
- Mesa, AZ
Parties
- Contractor
- NTT GLOBAL DATA CENTERS PH LLC
About commercial/industrial_projects Permits in AZ
0
commercial/industrial_projects permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
CONSTRUCT A 281 SF SWIMMING POOL & 54 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 2-IN PE PIPE FROM EXISTING GAS METER TO 1ST TEE, 2-IN PE PIPE FROM 1ST TEE TO 2ND TEE, 2-IN PE PIPE FROM 2ND TEE TO 400K BTU POOL HEATER, 1-IN PE PIPE FROM 2ND TEE TO 100K BTU BBQ, 1-IN PE PIPE FROM 1ST TEE TO 3RD TEE, 3/4 PE PIPE FROM 3RD TEE TO 1ST 75K BTU FIRE WOK, AND 3/4-IN PE PIPE FROM 3RD TEE TO 2ND 75K BTU FIRE WOK. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF
9936 E STROBE AVE · PMT26-11528
R-4 OCCUPANCY GROUP CONDITION 1. Community Residence Registration Application and Certificate of Occupancy for a residential care home operating as a Family Community Residence - Residential Behavioral Health. Name: Community Healthcare System, LLC. Applicant requested 8 number of residents. MZO allows up to 10 residents, excluding staff. No skilled nursing services. 24-hour care. R-4 Occupancy Group Condition 1. MBC 310.5: This occupancy condition shall include buildings in which all persons r
1031 S CANFIELD · PMT26-07911
New grey shell tilt up wall building. Group B, F-1, and S-1 occupancies. Type III-B construction. Building 44,856 SF, Canopies 264 SF, Total 45,120 SF. Civil site work. New 2-inch domestic water meter service and water meter. New 1-inch landscape water meter service and water meter. New pluming waste lines with 250 gallon interceptor for (2) trench drains at wash bays and stub ups for future restrooms. New mechanical RTUs. New 1600A 3 phase electrical SES and meter. Special inspections require
10658 E RUBIDIUM AVE · PMT26-08168
Add an access control card reader and panic hardware to a single exterior door. Approved as noted. Results in CofC.
8127 E RAY RD · PMT26-08108
Similar commercial/industrial_projects Permits
New grey shell tilt up wall building. Group B, F-1, and S-1 occupancies. Type III-B construction. Building 44,856 SF, Canopies 264 SF, Total 45,120 SF. Civil site work. New 2-inch domestic water meter service and water meter. New 1-inch landscape water meter service and water meter. New pluming waste lines with 250 gallon interceptor for (2) trench drains at wash bays and stub ups for future restrooms. New mechanical RTUs. New 1600A 3 phase electrical SES and meter. Special inspections require
Mesa, AZ · PMT26-08168
New water kiosk. Our units are pre-manufactured, stand-alone, unmanned water vending station typically placed in 2 leased parking spots in a local shopping plaza. Local review & inspection is primarily on the foundation and utility connections.
Mesa, AZ · PMT26-14860
Building 2 (Suite 115). New detached shell building with stub up utilities to the spaces. Deferred fire sprinklers. Deferred fire alarm. Metal carport canopy under a separate permit. Special inspections required for: Steel, Concrete and Masonry construction. Deferred pre-engineered trusses and deferred prefabricated metal stairs. Results in CoC.
Mesa, AZ · PMT25-07298
We are installing new magnetic locks (on the 2nd & 4th floors). They are being tied into the fire system and new access control system.
Mesa, AZ · PMT26-19361
AFP26-01140 Install electrical receptacles and compressed air drops for equipment being relocated from B543 to B531. Work includes adding a wall and door separating office from shop area
Mesa, AZ · PMT26-19371
About commercial/industrial_projects Permits in Mesa, AZ
What is a commercial/industrial_projects permit?
A commercial/industrial_projects permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.