RESIDENTIAL - FAU CHANGE OUT
RESIDENTIAL
RESIDENTIAL - FAU AND AC CHANGE OUT
RESIDENTIAL - FAU AND AC CHANGE OUT
BALCONY-LOFT-ENG
SOLAR PV WITH ESS
PATIO-LATTICE-ENG
SOLAR PV WITH ESS
PANEL UPGRADE SAME LOCATION
MISCELLANEOUS ELECTRICAL
SOLAR PANELS-PHOTOVOLTAIC SYSTEM
BLDG 8 - New 248 dwelling apartment complex composing of (12) two and three stories multi-family buildings, (1) clubhouse/leasing building with pool, (14) five-bay garages. VB construction. R-2 & A-3 Occupancy. Deferred fire sprinklers and fire alarms. Related to Civil improvements under PMT24-01715. New 4" domestic water meter. Under separate permits: pool, carport, signage, access control.
345 UNIT MULTI-FAMILY COMPLEX, 4 STORY HEIGHT. MFC 903.3.1.1, NFPA 13 FIRE SPRINKLER SYSTEM IS REQUIRED FOR R-2 OCCUPANCIES. FIRE SPRINKLERS AND STANDPIPE SYSTEM IS INCLUDED IN PLAN SET. ALL UNITS PLUS CLUBHOUSE AND LEASING & FITNESS ARE ALL CONTAINED IN ONE BUILDING. DEFERRED FIRE ALARM. DEFERRED VEHICLE ACCESS GATE. SPECIAL INSPECTIONS REQUIRED - EMERGENCY RESPONDER RADIO COVERAGE MFC 510. SPECIAL INSPECTIONS REQUIRED PENETRATIONS IN FIRE RATED ASSEMBLIES. CIVIL AND LANDSCAPE PLANS UNDER PMT2
6833 E Hobart St. Bldg 3: 3-story, type V-B construction, 2,651 SF, R-2 occupancy and 471 SF, U occupancy. Special inspection Req. - concrete, anchors, fire resistance penetration & joints, soils. Deferred prefabricated trusses, prefabricated staircases. Deferred fire sprinklers, fire alarm and vehicle access gates. Water meters: (5) 1-inch Domestic. REF: PMT24-18912 primary permit. Results in CoO.
6833 E Hobart St. Bldg 5: 2-story, type V-B construction, 1,559 SF, R-2 occupancy and 468 SF, U occupancy. Special inspection Req. - concrete, anchors, fire resistance penetration & joints, soils. Deferred prefabricated trusses, prefabricated staircases. Deferred fire sprinklers, fire alarm and vehicle access gates. Water meters: (5) 1-inch Domestic. REF: PMT254-18912 primary permit. Results in CoO.
6833 E Hobart St. Bldg 1: 3-story, type V-B construction, 2,651 SF, R-2 occupancy and 471 SF, U occupancy. Special inspection Req. - concrete, anchors, fire resistance penetration & joints, soils. Deferred prefabricated trusses, prefabricated staircases. Deferred fire sprinklers, fire alarm and vehicle access gates. Water meters: (5) 1-inch Domestic. REF: PMT24-18912 primary permit. Results in CoO.
Civil Improvements for a multi-family development, associated with the building permit PMT25-04719. Approx 2.2 Acres.
6833 E Hobart St. Bldg 2: 3-story, type V-B construction, 2,651 SF, R-2 occupancy and 471 SF, U occupancy. Special inspection Req. - concrete, anchors, fire resistance penetration & joints, soils. Deferred prefabricated trusses, prefabricated staircases. Deferred fire sprinklers, fire alarm and vehicle access gates. Water meters: (5) 1-inch Domestic. REF: PMT24-18912 primary permit. Results in CoO.
BLDG 9 - New 248 dwelling apartment complex composing of (12) two and three stories multi-family buildings, (1) clubhouse/leasing building with pool, (14) five-bay garages. VB construction. R-2 & A-3 Occupancy. Deferred fire sprinklers and fire alarms. Related to Civil improvements under PMT24-01715. New 4" domestic water meter. Under separate permits: pool, carport, signage, access control.
EXPEDITE - the GRID - North Building Package This permit is to capture residential impact fees. PMT20-01758 must be approved to issue this permit.
Civil improvements for 72 unit apartments at Gardens at Meridian. Water Meters: (1) 1-inch Landscape. (1) 200A 1ph panel with Elect meter. Special inspection req - concrete. Results in CoC.
BUILDING 2 FOR A 236 UNIT MULTI-FAMILY APARTMENTS - SLAB ON GRADE WOOD FRAME CONSTRUCTION OF 1-3 STORY BUILDINGS, ON-SITE AMENITIES AND CLUBHOUSE. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELEVATORS. building 2 R-2 occupancy VA construction area 33,942 SF 144 Occupants 24 units 1920000 btu gas meter
BUILDING 15 FOR A 236 UNIT MULTI-FAMILY APARTMENTS - SLAB ON GRADE WOOD FRAME CONSTRUCTION OF 1-3 STORY BUILDINGS, ON-SITE AMENITIES AND CLUBHOUSE. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELEVATORS. building 15 R-2 occupancy VA construction area 33,942 SF 144 Occupants 24 units 1920000 btu gas meter
BUILDING 17 FOR A 236 UNIT MULTI-FAMILY APARTMENTS - SLAB ON GRADE WOOD FRAME CONSTRUCTION OF 1-3 STORY BUILDINGS, ON-SITE AMENITIES AND CLUBHOUSE. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELEVATORS. building 17 R-2 occupancy VA construction area 28,002 SF 96 Occupants 24 units 1440000 btu gas meter
BUILDING 1 FOR A 236 UNIT MULTI-FAMILY APARTMENTS - SLAB ON GRADE WOOD FRAME CONSTRUCTION OF 1-3 STORY BUILDINGS, ON-SITE AMENITIES AND CLUBHOUSE. ELECTRIC VEHICLE GATES INCLUDED IN THIS PERMIT. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELEVATORS. R-2 occupancy VA construction area 28,002SF 96 Occupants 24 units 1440000 btu gas meter
BLDG 10 - New 248 dwelling apartment complex composing of (12) two and three stories multi-family buildings, (1) clubhouse/leasing building with pool, (14) five-bay garages. VB construction. R-2 & A-3 Occupancy. Deferred fire sprinklers and fire alarms. Related to Civil improvements under PMT24-01715. New 4" domestic water meter. Under separate permits: pool, carport, signage, access control.
Building Plan Set for 72 Residential apartment-style units. Separate Civil submittal record/permit# PMT25-01384. Deferred fire sprinklers, fire alarm and electric vehicle gate.
Clubhouse building, leasing office and site landscaping. Type V-B construction, 6,924 SF, Groups A-3, B and S-1 occupancies. Special inspections: Steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. Pool, building signage, canopies and carports under separate permit. Deferred submittal: Roof trusses, storefront, fire sprinklers and fire alarms. Water meters: (1) 1-inch domestic. Permit approved with comments. Results in CofO.
BLDG 12 - New 248 dwelling apartment complex composing of (12) two and three stories multi-family buildings, (1) clubhouse/leasing building with pool, (14) five-bay garages. VB construction. R-2 & A-3 Occupancy. Deferred fire sprinklers and fire alarms. Related to Civil improvements under PMT24-01715. New 4" domestic water meter. Under separate permits: pool, carport, signage, access control.
Office Building = 484 sf, Group B Occupancy and type V-B construction. Within a new 29-unit multi-family project with 11 detached units and 18 attached units Townhomes. Group R-2 Occupancy and Type V-B Construction. No Civil Plans or Design Reports included with this submittal. No civil reviews completed under this permit. Civil plan review is under PMT24-13087. Deferred fire sprinklers, fire alarm, access control. Special Inspections Required for Post-installed anchorage into concrete (if occur