The Ray Road Improvements consist of constructing a new six (6) lane roadway section from Ellsworth Road to Hawes Road. The improvements include new pavement, curb, gutter, sidewalks, pavement markings, signage, storm drain, ITS, and street lighting. New traffic signal improvements will take place at two (2) locations along Ray Road. Additionally, improvements to the City's Pressure Reducing Valve No.35 site will take place as part of the Ray Road Improvements. 1.5-inch landscape water meter.
Replaced 400 amp service like for like Four units G1 through G4. Field Verification Required to ensure Like for Like.
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS DECEMBER 15, 2025.
This project consists of 4,200SF building addition and 6,000SF renovation & finish refreshing to existing 1-story, type 1-A construction, I-2 condition 2 occupancy emergency department. Building addition consist of waiting room expansion and creating connection to pediatric ED. Renovation includes expanding charge nurse area, support spaces and corridors and interior finish refreshing at existing intake rooms. Site improvements include demo of existing waiting room, ED lobby canopy. New 1,049 S
Return to pre-loss condition, like for like, following fire damage in unit 252. No permit required for work to be done in the following units 253, 256 & 257.
Like for Like Replacement. Remove existing 200 AMP panel and replace with new 200 AMP panel only. Like for Like-no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit.
Modify existing building fire sprinkler system.
New 1931sf in-ground pool. Pool barrier under separate permit.
Construction, repair, remodeling, demolition, and excavation work may be conducted between 6:00 a.m. through 8:00 p.m. Monday through Friday. Work outside of this timeframe requires an after hours permit. After Hours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide the following information: a. Location of work: 4755 E Southern Ave Mesa AZ. 85206 b. Schedule of hours and days: WEDNESDAY 8/23 and W
Installation of additional exterior lighting on the generator platform and rooftop chiller platform of the existing building.
EXPEDITE- New 15,132sf building addition including awning/ canopy for storage, manufacturing, conference room, restrooms. 400sf outdoor seating area. VB construction. B/ S-1/ F-1 occupancy. Special inspection required for fabricator, steel, concrete, masonry, epoxy. Existing domestic and landscape meter to remain. Lot combination per ADM24-00195. Convert existing SES to distribution panel remove meter and transformer feed. Install new 1600A SES and connect existing distribution panel to new
EXPEDITE-RWCD Irrigation Pipe Construction with in the City ROW. Project address is 4755 E Southern Ave Mesa, AZ 85206
Install (3) automatic vehicle gates with knox box at all entry points into the property.
EdgeCore PH03 - Phase 3 Civil site improvements. Civil/SL/Landscape plans. No water meters, refer to building plans for meters.
Exterior and minor interior improvements to existing building. New 11342 SF warehouse building, S-1 occupancy group, type III-B construction, occupant load 23. Existing 1778 SF office building, B occupancy group, type V-B construction, occupant load 12. Special inspections for Steel Construction and Masonry Construction. Deferred Fire Sprinklers and Deferred Fire Alarms. Results in CoO. Landscape meter address is 3200 E MAIN ST LD1
New semi-public pool at new apartment complex. This permit is for pool/spa shells, pool equipment, emergency shutoff signage, and ada lift included only. All other pool site work and occupancy are under PMT25-04719. Type I-B Construction. Group A-5 Occupancy. Pool Area 131 SF, Spa Area 100 SF, Assembly Area 2962 SF. Occupant Load of 223. Results in CoC.
New concrete pad for new generator at existing cell tower site. New CMU screening wall and gate at generator. Special inspections required for concrete construction, masonry construction, and post installed mechanical anchors. Results in CoC.
Install clean agent fire suppression system in electrical container. Additionally, install 2019 NFPA 72 fire alarm system with notification and initiation devices.
Install clean agent fire suppression system in electrical container. Additionally, install 2019 NFPA 72 fire alarm system with notification and initiation devices.
Install 5 new automated racking systems, equipment only. No power on this plan set. Special Inspection for post installed anchors. Deferred fire sprinklers and fire alarms. Results in CoC.
Demo existing exterior hvac chillers, partial concrete slab, and pair of doors. Install new concrete slabs, double doors, and baler. Electrical and structural work. Special inspections concrete, soils, and epoxy/expansion anchors. Results in CoC.
Install new pedestal electrical meter. New 100A Single Phase Electrical Meter. Results in CoC.
AFTER HOURS PERMIT REFERENCE PMT18-05592. WORK TO BEGIN JULY 31 (1DAY) AND AUGUST 3 (1DAY) 2AM TO 6AM. ONSITE CONTACT PERSON: JIM SUMPTER 602-757 8238 OR GREG 480 322 1959. If the Building Safety Director should determine that the public health and safety will not be impaired by the erection, demolition, alteration, or repair (including excavation) of any building or the excavation of streets and highways within the hours of six (6:00) P.M. and five (5:00) A.M. during the months of May, June, Ju
THIS IS A USE PERMIT FOR TWO (2) TEMPORARY CONSTRUCTION FIELD OFFICE FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION PMT18--05592. THE CONSTRUCTION TRAILERS MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL I
Construction, repair, remodeling, demolition, and excavation work may be conducted between 6:00 a.m. through 8:00 p.m. Monday through Friday. Work outside of this timeframe requires an after hours permit. After Hours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant has provided the following information a. Location of work/address: PHX103h-N161 area / 1130 S San Jose, Mesa, AZ 85202 b. Schedule of hours and days specifically: 6:00a
Proposed improvements include construction of a single-story convenience store of 4,877+ SF with associated drive, gas pump, and vehicular parking.
Replace existing 400 amp service like for like For Units F 5-8
New 100A - 1-p Electrical Pedestal for Hawes Crossing Parcel G. Results in CoC.
Replacing the old FACU with a new FACU and cellular communicator. Installing a new smoke detector and manual fire alarm box. Results in CofC.
Provide power from spare breaker to new equipment control panel at existing building. New electrical. Results in CoC.