Search Permits
2,737 results · type: residential
SOLAR PV WITH ESS
BLDG 1 - New 248 dwelling apartment complex composing of (12) two and three stories multi-family buildings, (1) clubhouse/leasing building with pool, (14) five-bay garages. VB construction. R-2 & A-3 Occupancy. Deferred fire sprinklers and fire alarms. Related to Civil improvements under PMT24-01715. New 4" domestic water meter. Under separate permits: pool, carport, signage, access control. Code Mod: PMT25-05256
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 2: 2-story, type V-A construction, 17,655 SF, group R-2 occupancy and 184 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred f
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 1: 2-story, type V-A construction, 17,655 SF, group R-2 occupancy and 184 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred f
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 7: 3-story, type V-A construction, 30,550 SF, group R-2 occupancy and 209 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred f
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 3: 3-story, type V-A construction, 36,093 SF, group R-2 occupancy and 224 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred f
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 8: 4-story, type V-A construction, 44,607 SF, group R-2 occupancy and 209 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails, elevators,
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 5: 1-story, type V-B construction, 2,065 SF, group B occupancy Fitness center. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred fire sprinklers an
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 9: 4-story, type V-A construction, 44,607 SF, group R-2 occupancy and 209 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails, elevators.
Entire project consists of 260-units multi-family development comprising of (10) 1-4-stories buildings. Building 6: 3-story, type V-A construction, 36,093 SF, group R-2 occupancy and 224 SF, group U occupancy. Special inspection required for steel, concrete, masonry, soils, Fire-resistant Penetrations & Joints. Special inspection for Emergency Responder Radio Coverage for Building Type D and E. Deferred wood trusses, exterior bldg. envelope storefront, prefabricated stairs and rails. Deferred f
RESIDENTIAL - FAU AND AC CHANGE OUT
SOLAR PANELS-PHOTOVOLTAIC SYSTEM
PANEL UPGRADE SAME LOCATION
PATIO-ENCLO-ICC
PANEL UPGRADE SAME LOCATION
PANEL UPGRADE SAME LOCATION
SOLAR PANELS-PHOTOVOLTAIC SYSTEM
16501 Golden Crown Dr Septic
RESIDENTIAL - FAU AND AC CHANGE OUT
PATIO-SOLID
RESIDENTIAL - AC CONDENSER CHANGE OUT
PANEL UPGRADE SAME LOCATION
Harmon Septic
RESIDENTIAL - FAU AND AC CHANGE OUT
PATIO-SOLID-ENG
WINDOW CHANGE OUTS
RESIDENTIAL - FAU AND AC CHANGE OUT
Build new apartment facility. Building 4 of 4 Apartment Complex: (394) total units. 4-Story: Type V-A construction: Groups A-3.2, B, R-2, & U occupancies. Units include studio, one-, two-, and three-bedroom apartments. Amenities include covered and garage parking, pool, clubhouse, business office and refuse enclosure. (654) total parking stalls including garage (150), tandem (150), covered (244), and uncovered (110) spaces. Deferred fire sprinklers, fire alarm, trusses and electrical vehicle gat
Site improvement for a new multi-family developments, including Civil and Landscape. New 1.5" landscape meter. Building submittal under separate permit PMT24-02728.
SALES OFFICE