CELLSITE
TENANT IMPROVEMENTS
TENANT IMPROVEMENTS
Replace 200 amp disconnect bucket on existing SES panel. Results in CoC.
Development of new 5-story, 127 unit, 79,106 SF gross + 2,621 SF of 50% perforation canopies, type III-B construction, R-1 occupancy with A-2, A-3, B and S-1 accessory occupancy Springhill Suites Hotel. Landscape onsite included. Special Inspection req. - Steel, concrete, masonry, cast-in-place deep foundations, Anchors, EIFS, Fire-resistant penetrations & joints, Soils, smoke control, fire/smoke damper operation, HiPot Testing. Special Inspections required Emergency Responder Radio Coverage IFC
Replace all four existing RTU's with new like for like at existing building. New curb adapters for RTU's. Reuse existing condensate drain lines and electrical disconnects. Results in CoC.
Turf Conversion
Johnson Controls to install access control system to prevent unauthorized access into building and sensitive areas. All doors shall be configured to provide free egress per current code. Results in CoC.
Add wireless dialer to existing fire panel for communication to UL listed central station: COPS Monitoring. All devices to remain as existing, with no field changes or modifications. Cutsheets can be provided upon field inspectors’ request. Results in CofC.
A new private 6-inch DIP C- 900 fire sprinkler line will connect to the 6-inch water main within the site in the northwest portion of the project site. No new fire hydrants are proposed for the project site.
Install access control system with 5 controlled access doors. Approved with stipulation. Results in CoC.
Install new fire sprinklers for oven 4. Tie in to existing overhead system.
Phase 1 infrastructure project at Phoenix Mesa Gateway Airport.
New 10,791sf daycare, including 791sf attached awnings/canopies. VB. I-4 occupancy. 8,018 s.f. outdoor playground. New 1.5" domestic water meter and service. New 1" landscape meter and service. New gas meter. New 600A electrical service. Special Inspections Required for steel, welding, masonry, concrete, anchoring, and soil. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM.
CIP - This project will involve the removal and replacement of the existing fiberglass risers along with the removal and replacement of a portion of the existing concrete slab in order to eliminate water leakage.
Modify existing Ansul wet chemical Type I hood fire suppression system consisting of (2) 3-gallon tank supporting (13) flow points. Cooking equipment is existing. Refer to FPD25-12690 deficiency report. Approved with stipulations. See comments.
Related to COB26-00023. Like-for-Like replace of SES after existing equipment was damaged by a vehicle impact. SES already deenergized by SRP. Electrical plans approved under PMT20-09476 to be used for reconstructing the SES equipment.
At-Risk Grading Permit - Civil Reviewer Demian Thomas
Construction, repair, remodeling, demolition, drilling, landscape maintenance, landscaping, lawn or yard work, wood cutting, including crafts and hobbies, or excavation work conducted between 6:00 a.m. through 8:00 p.m. Monday through Friday. A person may engage in or permit such activities at that person's residence between 6:00 a.m. and 8:00 p.m. on Saturday or Sunday. Landscape maintenance and landscaping at golf courses and private parks between 5:00 a.m. and 8:00 p.m. on all days is also ex
PBI Replacement of SES for overhead service repair. Service change from residential to commercial grade panel, remaining single phase electrical. New 200 AMP meter. Results in CoC.
EXPEDITE - MULTI-PERMIT PROJECT. THIS PERMIT IS FOR FOUNDATIONS FOR THE NORTH BUILDING. ISSUE C OF C WHEN COMPLETE. DOES NOT INCLUDE UNDERSLAB UTILITIES.
24.44 acres of open space - an extension of the Eastmark Great Park along S Binary and E Rubidium Ave. New landscaping, irrigation and amenity structures. New restroom building, monument signs, pickleball courts, tennis courts, volleyball courts, basketball courts, remote control vehicle track, Ninja Warrior course, exercise stations, and play structures. Code modification: PMT25-01380 Special Inspection Req. - steel, concrete, anchor, welding. Water meters: 1.5inch domestic, 4inch landscape.
Inground 648 SF shotcrete commercial swimming pool. Equipment by others. Structural design per AMMTec Consultants and MST19-00383, PLLC. Inspector to verify existing pool barrier. Results in CoC.
COB25-00042-Interior remodel of the ground and upper levels. Ground level minimal room changes-upper levels just finishes and minor electrical improvements. See attached cover sheet with full scope of work description. Ground level demo under a separate permit. Deferred fire sprinklers. Deferred fire alarm. Results in CoC.
Replacement of existing fire alarm control panel annunciator panel and voice evac control panel and local operator control All devices locations, back boxes and wiring to remain as is. Results in a CofC.
AFP26-01140: Install utility infrastructure for new oven #4
TENANT IMPROVEMENTS
TENANT IMPROVEMENTS
FIRE DAMAGE- This structure is to be restored like for like. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural: Structural members were damaged and will need replacing and engineering Electrical: Electrical sustained minor damage. Panel will not need to replaced, only wire/s that were damaged. Replace damaged wire per 2017 NEC and/or 2018 IRC/IBC Mechanical: Mechanical was not damaged
Modification to existing hood suppression system. Adjusting (2) 2-flow point nozzles over (1) burner range, (2) 1-flow point in plenum, and (1) 2-flow point nozzle in duct. 8 total flow points. Special Inspections Req - Final Inspection Modification to the existing system. Adjusting nozzles over appliances for proper coverage.