BLD F- 111893 SQ FT - 4 industrial buildings. See PMT22-13972 for offsite improvements and irrigation water meters. PARCEL- 30430023F. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELECTRIC VEHICLE GATES. DEFERRED PREFABRICATED FIRE PUMP HOUSE. SPECIAL INSPECTION - EMERGENCY RESPONDER RADIO COVERAGE.
Remove existing sprinkler monitoring system and replace it with a new building fire alarm system. Approved with Stipulation.
Install (2) trash enclosure gates on existing enclosures. Resulst in CoC.
Modify existing fire alarm panel by adding (3) photoelectric smoke detectors and (4) notification appliance circuit panels supporting (148) ceiling-mounted horn/strobes. Ref: PMT25-21732
THE PROJECT SCOPE INCLUDES THE INSTALLATION OF A NEW ELECTRIC VEHICLE (E/V) CHARGING STATION IN THE PARKING LOT ON THE EAST SIDE OF THE PROPERTY EXIST. ELECTRICAL UTILITIES WILL BE MODIFIED FOR THE INSTALLATION.
Installation of a temporary 60' flagpole for Dream Finders Homes Canyon Pointe Village model home complex.
Building addition. The addition will add approximately 461 Square feet to the total site building. Occupancy classification B, construction type IIB. This permit includes associated mechanical, electrical and plumbing. The addition is to allow us to install additional lockers to accommodate our workforce. Special Inspections required for concrete, soils, steel/light gage steel welding, post-installed anchors/dowels, epoxy/expansion.
TENANT IMPROVEMENTS
STORAGE RACKS
This City of Mesa (City) Broadway Road Phase 1 project (City Project No. CP0666) consists of full street improvements along Broadway Road from Lesueur to Spur replacing pavement, curb, gutter, sidewalk, and adding bike lanes. New utility lines will also be included in Broadway Road for water transmission, water distribution, high-pressure gas, intermediate pressure gas, storm drain, street lights, and landscaping. Existing private irrigation facilities will likely be relocated on the south side
EdgeCore PH02 - First, Second, and Third Floor build out and installation of electrical, mechanical, and plumbing equipment. Access control plans provided. Install generators with 450 diesel gallon tanks and 50K gallon diesel fuel tanks in yard. Deferred fire sprinklers and fire alarms. Results in CoC.
Development of single-story shell building with 2 suites, 11,069 SF, Type V-B construction, Group B / S-1 occupancy. Development includes Civil Site Improvements. Special Inspections Required - Masonry, Steel, Concrete, Soils. No high-piled combustible storage. Water meter: 1-inch landscape and 2-inch domestic. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. Results in CoC. TI to be resubmitted to obtain CoO for Suite 105 REF: PMT24-20321.
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL **9/30/2025**. POWERE
EXPEDITE Half street improvements of Pecos Rd along the frontage of the MPCA expansion site. Improvements include roadway, signing & marking, streetlighting, drainage, and ITS.
New 3-Bay 11,209 SF construction type V-B fire station, New building with sleeping areas and kitchen, MEP's and finishes, AST Diesel 1,000 gals and fill station, and limited civil work. New (1) 1-inch landscape meter, (1) 800 AMP electrical meter. Fire sprinklers included. Deferred building fire alarm, trusses, and I-joists. Special inspection for structural items. Results in CoO.
Extend conduits for SRP from Ellsworth Down Pecos
The ME02 metering station is owned by the City of Mesa and monitors wastewater flow from Mesa that is discharged into the SROG collection system for treatment at the 91st Avenue WWTP. As part of the SROG partnership, the City of Phoenix maintains separate communication systems on site. This project is to update the City of Phoenix communication equipment at the metering station.
Commercial Electrical Repair Like for Like-no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit.
Construction, repair, remodeling, demolition, and excavation work activities may be conducted between May 1st and October 15th of each year between the hours of 5:00 A.M. and 7:00 P.M. Monday through Friday and between the hours of 7:00 A.M. and 7:00 P.M. on Saturday. Construction work outside of the permitted timeframes will require an afterhours permit. Afterhours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide th
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE TRAILER FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS MARCH 31,
TENANT IMPROVEMENTS
New 24,000 SF type V-B office building. Civil permit PMT25-21027. New 2-inch domestic water meter, new electric meter. Fire sprinkler monitoring system is required by separate over the counter (OTC) related submittal. Deferred fire sprinklers and trusses. Special inspection for structural and electrical items. Results in CoO.
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE TRAILER FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS MARCH 31,
TENANT IMPROVEMENTS
STORAGE RACKS
BLDG G + ONSITES- 111893 SQ FT 4 industrial buildings. See PMT22-13972 for offsite improvements and irrigation water meters. PARCEL- 30430023F. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED ELECTRIC VEHICLE GATES. DEFERRED PREFABRICATED FIRE PUMP HOUSE. SPECIAL INSPECTION - EMERGENCY RESPONDER RADIO COVERAGE.
BUILDING 1 - Suite 1.-Project scope consists of (2) new office/warehouse, equipment yard and parking lot. the West building includes a full buildout of 5,600 SF office over 2 floors and a 4,250 SF warehouse on fist floor. Group B & S-1 occupancies. Type V-B construction. Office space includes conference room, break area and restrooms. Includes a 1-inch landscape water meter and (2) 1-inch domestic water meters and (1) 400A 3-p electric service meter. Special Inspections required for: Steel, Con
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE TRAILER FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS DECEMBER 3
Construction, repair, remodeling, demolition, and excavation work may be conducted during Summer Days and Dates May 1st – Oct 15th Monday through Friday 5am – 7pm (4am for concrete placement) & Saturday 7am-7pm (6am concrete) Work outside of this timeframe requires an afterhours permit. Afterhours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide the following information: a. Location of work 5341 S Power b. Schedule