At Risk Foundation Only , Building 4 (REF: PMT25-05848). Special inspections required soils, concrete, and post-installed anchoring. Results in CoC.
Modify existing fire alarm system by adding (2) wall-mounted speaker strobes, (1) wall-mounted strobe, (2) smoke detectors, and replacing (3) smoke detectors. Reference AFP permit PMT24-10944 for floor plan.
Civil Improvement Plans for a residential garden style development and associated amenities. New (2) 8-inch domestic and (1) 1.5-inch landscape meter. Results in CoC.
Replace 2-inch underground electrical riser feeding a 200 AMP electrical panel. Like-for-like replacement.
Annual Facilities
New 5,450 SF Type VB construction, B and S-1 occupancy office and truck shop facility for TMS International. Private water line. No new Domestic water or Elect meters. Development includes civil site improvements. Special Inspection Req. Steel, concrete, masonry, fabricators, post-installed anchors. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM.
Install of (3) new panel antennas and (3) new fiber cables to existing light pole and elect pedestal. Results in CoC.
Group F-1 Occupancy. Construction type II-B. 4,122 SF. New equipment yard building at new facility. Building is to house switchgear and battery storage. Special Inspections Required: Steel Construction, Concrete Construction, and Soils. No water to building. Electrical is fed from site power. New architectural, structural, and mechanical. Approved with Stipulation: Fire protection shall be by Deferred Submittal. IFC 903, MAC 4-1-4. Results in CoC.
New 2,795 SF shell retail building, type V-B construction. New 100 AMP electric meter and 1-inch domestic water meter. Special inspections required for concrete, soils, and post-installed anchors. Deferred fire sprinklers and truss calculations. Fire sprinkler monitoring under separate related OTC permit. Results in CoC.
ZF AFP ANNUAL FACILITIES PERMIT FOR ZF PASSIVE SAFETY SYSTEMS US INC FOR YEAR 2026
AFP26-05372 FOR BUILDING 15 AREA 'G', WORK INCLUDES THE DEMOLITION OF THE EXISTING FLEXCELLS 194, 195, 196, 305, 307, 309. WORK ALSO INCLUDES THE DEMOLITION OF ANY TEMPORARY STAGING PALLETS AND FORKLIFT TRAFFIC BARRIERS. FOR BUILDING 15 AREA 'N', WORK INCLUDES THE REMOVOAL AND RELOCATION OF TWO WELDERS IN THE SAME BAY. SCOPE ALSO INCLUDES THE RELOCATION OF THE EXISTING FLEXCELLS 194, 195, 196, 305, 307, 309 ALONG WITH ITS SUPPORT EQUIPMENT. HD 1.4 WILL NOT EXCEED 50 LBS. IN USE AND 50 LBS. IN ST
New electrical gear and power skids to power up building 1. New 3000A 3 phase electrical meter. Special Inspection required: High Potential Test for Services 1000A or greater. Results in CoC.
AFP26-05372 FOR BUILDING 15 AREA 'G', WORK INCLUDES INSTALLATION OF 2 HOT FORMING LINE AND 1 COLD FORMING LINE WITH SUPPORT EQUIPMENT. NEW HOT AND COLD FORMING LINES WILL TIE IN AND USE EXISTING MECHANICAL & ELECTRICAL PROVISIONS ALREADY SUPPLIED BY THE BUILDING.
BLD A (9422 E. GERMANN Rd) THIS PROJECT CONSISTS OF A NEW ONE-STORY TILT-UP CONCRETE WAREHOUSE WITH TRUCK LOADING THAT SHARES A SITE WITH 5 OTHER FREE-STANDING WAREHOUSE BUILDINGS OF SIMILAR SIZE. THE WAREHOUSE IS DESIGNED FOR HIGH-PILE STORAGE ON RACKS AND PROVIDES REQUIRED FIRE APPARATUS AND FIRE FIGHTER ACCESS FOR THE SITE AND BUILDING. THIS PROJECT IS ONLY FOR THE CONSTRUCTION OF THE SHELL BUILDING. FUTURE TENANTS MUST SUBMIT SEPARATE PLANS THAT WILL INDICATE LAYOUT FOR TENANT BUSINESS AN
NEW GROUND UP WENDY'S RESTAURANT BUILDING INCLUDING SITE IMPROVEMENTS AND DRIVE-THRU CANOPY, OUTDOOR DINING CANOPY, NEW PARKING, DRIVE THRU, AND TRASH ENCLOSURE. OCCUPANCY CLASSIFICATION A-2, CONSTRUCTION TYPE VB. NEW DRIVE ISLANDS.HOOD AFES IS INCLUDED IN THIS PLAN SET. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. DEFERRED CO2 DETECTION AND ALARM. NEW GAS METER. NEW 3-PHASE ELECTRIC METER. NEW GREASE INTERCEPTOR. Special inspections required for steel, fabricators, concrete, wood, soils, EIF
Remove and Replace: (2) Rooftop Pkg units, (1) DOAS unit, (10) exhaust fans and (2) supply fans. Scope include Mech, Plumbing, Electrical and Structural associated with rooftop units. Special Inspection Req. - Steel. Results in CoC.
Install new pedestal electrical meter. New 100A Single Phase Electrical Meter. Results in CoC.
At Risk Foundation Only , Building 5 (REF: PMT25-05849). Special inspections required soils, concrete, and post-installed anchoring.
TENANT IMPROVEMENTS
TENANT IMPROVEMENTS
STORAGE RACKS
ELECTRICAL COMMERCIAL
Replace 3 existing electrical panels with 3 new - 400A single phase multi meter bank panels, like for like. Results in CoC.
Replace two 100 amp, 240 volt disconnects like for like.
Install of a 3,995 SF, type II-B, F1 occupancy free-standing Pre-Engineered Metal Building (PEMB). Paint and Sandblast Booth includes mechanical units and electrical light fixtures. Primary functioning of the facility will be repair and maintenance of large mining equipment. Scope includes structural slab, and plumbing and electrical connection update from PMT25-02775. Special inspection form - concrete, anchors and soils. The color scheme of the PEMB has been approved through DRB24-00473 / ADM2
ADDING CELLULAR DIALER TO AN EXISTING SYSTEM
Annual Facilities Permit for ePac Flexible Packaging - Mesa Site.
Existing metal carport (as-build) REF COB24-00174, as per plans
TENANT IMPROVEMENTS
TENANT IMPROVEMENTS