PermitDig

Search Permits

2,926 results · type: commercial

New conduit from an existing HOA pedestal. (22) new LED 24WATT 3000 CCT bollards, along water's edge in park from behind home of 2729 W Napal Cir and 2701 W Nido Ave. Field to verify electrical protections near wet locations. Results in CoC.

2723 W NATAL CIR LD1, Mesa
Apr 7

Add wireless dialer to existing fire panel for communication to UL listed central station: COPS Monitoring. All devices to remain as existing, with no field changes or modifications. Cutsheets can be provided upon field inspectors’ request.

9317 E RAY RD, Mesa
Apr 7

REMODEL GARAGE TO SALES OFFICE FOR A MODEL HOME COMPLEX. ALL WORK SHALL COMPLY WITH 2024 IBC, 2024 IRC, 2023 NEC, 2017 ADA A117.1. THIS HOME IS NOT TO BE INHABITED UNTIL THE SALES OFFICE IS CONVERTED BACK TO A GARAGE. GARAGE AREAS MODIFIED OR IMPROVED FOR THE PURPOSE OF PROVIDING A TEMPORARY OFFICE SHALL BE RESTORED BACK TO A GARAGE PER PARKING STANDARDS IN CHAPTER 32 OF ZONING ORDINANCE PRIOR TO THE SALE OR RESIDENTIAL OCCUPANCY OF SUCH MODEL HOME. SECURITY STANDARDS TO BE MET PER SEC R328. R

3036 E ELMWOOD ST, Mesa
Apr 7

Running new 3/4" gas line from Meter located on NORTHWEST Corner of Building located near boiler room / laundry room. New gas line will be 3/4" galvanized steel above ground and transition with approved transitional riser to run underground SDR 11 P.E. piping with tracer wire attached at the proper 18" depth approximately 127 feet going SOUTHWEST towards NE Corner of Swimming Pool area (on the exterior side of the gate). Will transition back to galvanized steel to stub up to feed [2] future BBQ

901 S DOBSON RD, Mesa
Apr 7

New perimeter lighting installed on the edge of building roof and gas pump canopy roof at existing building. New electrical. Results in CoC.

1141 S CRISMON RD, Mesa
Apr 7

New 3,938 SF construction type V-B shell retail building with 1,088 SF of overhangs (north of the drive overhang-canopy). Special inspection for fabricators, steel, concrete, masonry, post-installed anchoring, and fire-rated assemblies. Civil, electric meters and water meters under PMT23-08741. Fire Sprinklers under PMT23-08741F. Addendum under PMT23-08741D for building changes. Related to PMT23-08741. Fire alarm plans will be submitted under PMT23-08741. Results in CoC.

3461 S ELLSWORTH RD, Mesa
Apr 7

Install a 1000-gal u/g LP tank with cathodic protection and twin stage regulators *(no ignition, p/l, openings, or structure within 10 ft*). 115 ft of 2" P.E. To pool heater (400k btu), "t" 10 ft of 3/4" P.E. to BBQ (75k btu). 95 ft of 1 1/4" P.E. To fire pit (150k btu).

10136 E SOUTHERN AVE, Mesa
Apr 7

MISCELLANEOUS ELECTRICAL

132 BUSINESS CENTER DR, Corona
Apr 6

Haydon is submitting this application for an After-Hours Work Permit as it relates to Permit PMT23-13926. Requested information for this permit is as follows: 1. The applicant must provide the following information: a. Location of work: 7232 E. Elliot Rd. Mesa, AZ 85212 b. Schedule of hours and days: a. Saturday, November 18th, 2023, 6:00am - 5:00pm b. Saturday, November 25th, 2023, 6:00am - 5:00pm c. Saturday, December 2nd, 2023, 6:00am - 5:00pm d. Saturday, December 9th, 2023, 6:00am - 5:00pm

7232 E ELLIOT RD, Mesa
Apr 6

New cantilever racking at existing building. New structural. Special Inspections for Post Installed Anchors. Results in CoC.

8951 E WARNER RD 144, Mesa
Apr 6

Existing overhead feeders damaged by truck at mobile home park and apartment complex. Install new feeder to existing ses with no meter to feed affected area. New electrical meter 200A Single phase. Results in CoC.

1021 W MAIN ST, Mesa
Apr 6

Change of use for the main building/building 1 of the Gamrosa Temple. Records show previous use was for a school for youth. Converting the building to a residence for the Monks. This is a change of use permit resulting in a Certificate of Occupancy at final inspection. REF HOST 195713

3939 E UNIVERSITY DR 1, Mesa
Apr 6

DUPLICATE CERTIFICATE OF OCCUPANCY. NAME CHANGE ONLY: ORION COUNSELING CENTER LLC. 1861 SQ FT PROFESSIONAL OFFICE SUITE FOR COUNSELING SERVICES, B OCCUPANCY. EXISTING TYPE VB CONSTRUCTION. MAX 30 OCCUPANTS. NO WORK UNDER THIS PERMIT. PREVIOUS RECORDS SHOW C OF O FOR THE ASPIRE BEHAVIORAL CARE LLC, REFERENCE PERMIT PMT21-20428. THE INTENTION OF THIS PERMIT IS TO DUPLICATE A PREVIOUSLY PERMITTED OCCUPANCY CLASSIFICATION ONLY. THIS PERMIT REQUEST DOES NOT AUTHORIZE OR APPROVE UNPERMITTED CONSTRUCTI

5604 E MAIN ST, Mesa
Apr 6

12001 OLD BALTIMORE PIKE SEPTIC

12001 OLD BALTIMORE, BELTSVILLE
Apr 6

Development of a 6,000 SF one-story office/warehouse building, Type VB construction, group B and S-1 occupancy. Deferred fire sprinklers and fire alarms. (1) 1.5inch Domestic Water meter and (1) Elec 3ph meter. Special Inspection req: Steel, concrete, masonry, welding, epoxy anchors, and soils. Ref: PMT24-15416 for Civil and Landscape site improvements. Results in CoO.

7218 E PECOS RD, Mesa
Apr 3

RAMIREZ GRANDE REPAIRS

13004 LIVINGSTON, FORT WASHINGTON
1KApr 3

Repair & replace building components damaged during fire incident including mechanical and electrical. Deferred fire sprinklers, fire alarms and miscellaneous metal fabrications. Group F-1 occupancy, type II-B construction. Special inspections required for steel, fabricators, soils, structural steel, post-installed anchors.

145 S NINA CIR, Mesa
Apr 2

New pool restroom and storage room, 304 SF type VB construction. No new meters. Special inspection for structural items. Approved with comments. Results in a CoO.

8137 E BROWN RD, Mesa
Apr 2

MODIFICATION OF EXISTING SPRINKLER SYSTEM. PROVIDE AND INSTALL FIRE SPRINKLER HEADS AS NEEDED TO PROVIDE PROPER COVERAGE AND MEET CURRENT CODE REQUIREMENTS.

1839 W 1ST AVE, Mesa
Apr 2

To install and create a complete access control system.

9253 E WILLIS RD 101, Mesa
Apr 2

This contract includes the installation, termination and testing of fire alarm devices required for the protection of Rhodes Junior High School-Polaris Campus. PBFS has provided technical labor in order to remove and keep safe the following devices, 32 audio visual devices, 54 detection devices and miscellaneous modules. Devices will need to be stored in a safe location provided by the school. Devices will be re-purposed for the new layout. Please note some new devices will be required to satisf

1860 S LONGMORE, Mesa
Apr 2

Onsite work for future 102-acre technology campus. No buildings included in this permit. Includes 2" domestic water meter.

3550 S SIGNAL BUTTE RD, Mesa
Apr 1

Traffic Signal

9260 E RAY RD, Mesa
Apr 1

Phase 1 building smart cooling. (2) areas of modification on-site. Adding (2) new water storage tanks, (2) pump enclosures Utility buildings 270 SF each and (2) water softener enclosure to the area west of the western loop road. As well as modification to the ACC yard pavement. Special inspection required for soils, concrete, steel, and electrical. Results in CoC.

7232 E ELLIOT RD, Mesa
Apr 1

New 2000A SES and bollards at existing building. New electrical meter 2000A 3 phase. Special Inspection required for services rated 1000A or greater. Approved as noted. Results in CoC.

8341 E PECOS RD, Mesa
Apr 1

The project consists of the construction of a proposed new office building with all required landscaping, grading & drainage, utility and paving improvements. New 1-inch water service with a 1-inch irrigation water meter. Results in CoC. Ref new construction of office building under PMT25-21329.

8026 E UNIVERSITY DR, Mesa
Apr 1

New perimeter exterior downlighting at existing gas canopy and building. Results in CoC.

816 W UNIVERSITY DR, Mesa
Apr 1

TENANT IMPROVEMENT OF EXISTING FIRE ALARM SYSTEM: PROVIDE AND INSTALL 2 NEW KITCHEN HOOD MONITORING AS SHOWN ON DRAWINGS, FIELD VERIFY EXACT LOCATION. MANUAL FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING STATION. THE SUPERVISING STATION SHALL BE LISTED AS EITHER UUFX OR UUJS UNDERWRITERS LABORATORY OR SHALL MEET THE REQUIREMENTS OF FACTORY MUTUAL RESEARCH APPROVAL STANDARD 3011. SUPERVISION OF SYSTEM AND LEASED TELEPHONE LINES SHALL BE ARR

2015 S ALMA SCHOOL RD 102, Mesa
Apr 1

The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 1/13/2026 ADDRESS: 205 N COUNTRY CLUB DR MESA DAMAGE CAUSED BY: Vehicle Impact INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a

205 N COUNTRY CLUB DR, Mesa
Apr 1

AFP26-01284 PROJECT IS TO REPLACE THE EXISTING CT EQUIPMENT WITH A SIEMENS SOMATOM EQUIPMENT. IN ADDITION, AN EQUIPMENT SYSTEMS COMPONENT ROOM WILL BE ADDED WITH A ROOM FINISH REFRESH.

1400 S DOBSON RD, Mesa
Apr 1