Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
TENANT IMPROVEMENTS
New 41,315sf 2-story Tower A and B shell buildings connected with metal trellis walk-way, with covered outdoor patio. Mixed occupancies of business, restaurant, and adult school. B/ A2 occupancies. IIB construction. The site includes new access roads, new retention, landscaping, and parking. Special inspection required for steel, concrete, masonry, EIFS. Special inspection for fire line flush. (4) 2" domestic water meter, and 1" landscape meter. New 3000A electrical service. A future exit sta
REF: PMT25-00077 for building - New layout. New four-story slab-on-grade, wood framed building with TPO membrane roof. Building is used for guestrooms, registration, laundry and mechanical and electrical rooms. Stair enclosures are protected by a two-hour rated, interior separation. Accessible rooms are located on the first through fourth floors. The roofing is class "A." Deferred fire sprinklers, fire alarms, access control, hold down anchor rod system, wind uplift rod system, aluminum canopies
North lot temporary power for temporary construction trailers. REF TEMP CONSTRUCTION TRAILER PERMIT PMT24-03169.
Increased building by 2,567 SF. Ref parent permit PMT23-20388. Ref site improvements PMT23-20388A. New four-story slab-on-grade, 56,823 SF (54,256 SF+2,567 SF), Type V-A construction, group R-1 occupancy building with TPO membrane roof. 124 units including 7 accessible units. Elevator and Stair enclosures are protected by a two-hour rated, interior separation. Deferred fire sprinklers, fire alarms, access control, hold down anchor rod system, wind uplift rod system, aluminum canopies. Special in
TI is for a new suite space within an existing shell suite. This project consists of a new demising wall to divide existing tenant space into two separate spaces and corridors. The remaining space will be for a future retail tenant under separate submittal and permit. Also included is the removal of a portion of existing masonry wall for the installation storefront and glass doors entry and the extension of the existing exterior parapet. Special inspection for structural items. Deferred fire spr
Remove three (3) existing AHLOA RRH units: and • Install three (3) AHLOB RRH units. Must comply with all stipulations listed on the approval administrative letter ADM26-000316.Results in CoC.
Modify existing fire sprinkler system adding/relocating 30 fire sprinklers at existing ticketing terminal. Installing a new fire sprinkler system with 4-inch fire riser, a new 4-inch main branch line and 151 fire sprinklers to new EDS building.
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Provide and install new addressable and notification fire alarm devices. Remove old Honeywell devices and replace with est devices in locations in 1st floor corridor h, 1st floor west main lobby, 2nd floor elevator 9/10 storage room & 4th floor elevator 9/10 mechanical room. Devices located outside the scope of work are existing and to remain unchanged.
Install 2 hip structure fabric canopies. 791 SF
New pool and spa. New electrical, structural, and pool equipment only. Pool fence to be installed on a separate permit, hold pool final until pool fence permit has been approved. New 200A 3phase electrical meter. Pool barriers under PMT26-06940. Results in CoC.
Pool barrier for 1,647SF, A-3 occupancy of the pool area and 6 FT south property line fence. Pool under PMT25-13040. Special inspection required for masonry, concrete, and post-installed anchoring. Reviewed as noted. Results in CoO for pool area.
Install fire alarm system with occupant notification device in an existing facility. Group M occupancy.
Like for like replacement of the 400amp (4) meter pak panel supplying power to units #13, #14, #15, & #16. There will be no change in electrical loads/amps. Electrical panel replacement will comply with 2023 NEC.
Proposed Circle K convenience store with a vehicle fueling station at the Southeast quadrant of Pecos Road and Sossaman Road in Mesa, Arizona (Parcel ID 304-61-010C). The proposed Circle K will be constructed on a 1.9 acre lot. The development includes: • A 5,200 sq.ft. convenience store • 17 Standard parking spaces and 1 ADA parking space • A fuel canopy providing 6 fueling islands (12 fueling positions total) with underground fuel storage tanks • Associated landscaping, lighting and infrastruc
This is a CIP project. The City of Mesa has identified necessary water main replacements and/or abandonments at several locations throughout the City. Location 1 was completed through a separate contract. Location 2 – 82nd Place Boise Street to Billings Street Location 3 – 9th Street (Country Club Drive to Robson) and Robson (9th Street to 7th Street) Location 4 – Macdonald (3rd Place to University Drive) and 3rd Place (Macdonald to Center Street) o Install approximately 1,500 feet of 2-inch
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration